IAC

Yaskawa 05P00620-0027

A1000 - Load Reactors

3% and 5% impedance reactors may be used on the output to reduce the effects of load side transients on the motor.

Lifecycle & replacement

Lifecycle status not published

Yaskawa's published discontinuation lists (checked 2026-09-01) do not assign a lifecycle status to this part number.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Checked against: Yaskawa America Support By Product - Inverter Drives; Yaskawa America Support By Product - Servo Amplifiers; Yaskawa America Support By Product - Servomotors; Yaskawa America Support By Product - Machine Controllers; Yaskawa America Support By Product - PLC Controllers; Yaskawa America Support By Product - Spindle Drives; Yaskawa America Support By Product - Spindle Motors; Yaskawa product page carrying the verbatim definition of Legacy.

Technical specifications

200-240V, 3% Line/Load Reactors
Rated Input Voltage200-240V, 3-Phase
Nominal HP1.5
Nominal 3% Impedance - Reactor Rated Current (A)8
Nominal 3% Impedance - Inductance (μH)1500
Nominal 3% Impedance - Weight (lb)14
Drive Model Number - Normal DutyCIMR-AU2A0006
Drive Model Number - Heavy DutyCIMR-AU2A0008
200-240V, 3% Line/Load Reactors [A1000 - Load Reactors]
Rated Input Voltage200-240V, 3-Phase
Nominal HP2
Nominal 3% Impedance - Reactor Rated Current (A)8
Nominal 3% Impedance - Inductance (μH)1500
Nominal 3% Impedance - Weight (lb)14
Drive Model Number - Normal DutyCIMR-AU2A0008
Drive Model Number - Heavy DutyCIMR-AU2A0008
G7 Reactor Options
Rated Output Current (Amps)6
3% Enclosed Reactor - Dimensions (in) - H8
3% Enclosed Reactor - Dimensions (in) - L8
3% Enclosed Reactor - Dimensions (in) - W6
5% Enclosed Reactor - Dimensions (in) - H8
5% Enclosed Reactor - Dimensions (in) - L8
5% Enclosed Reactor - Dimensions (in) - W6
Drive Model Number CIMR-G7U20P71
5% Enclosed Reactor - Part Number 05P00620-05P00620-0028
G7 Reactor Options [G7 Reactor Options]
Rated Output Current (Amps)8
3% Enclosed Reactor - Dimensions (in) - H8
3% Enclosed Reactor - Dimensions (in) - L8
3% Enclosed Reactor - Dimensions (in) - W6
5% Enclosed Reactor - Dimensions (in) - H8
5% Enclosed Reactor - Dimensions (in) - L8
5% Enclosed Reactor - Dimensions (in) - W6
Drive Model Number CIMR-G7U21P51
5% Enclosed Reactor - Part Number 05P00620-05P00620-0028
240V, 1-Phase Input, 3% AC Output Reactors
Nominal HP1
Catalog Code - Heavy DutyGA50UB006
Part Number - Open Type05P00620-0024
240V, 1-Phase Input, 3% AC Output Reactors [GA500 - AC Output Reactors]
Nominal HP1.5
Catalog Code - Normal DutyGA50UB006
Part Number - Open Type05P00620-0024
240V, 3-Phase Input, 3% AC Output Reactors
Nominal HP1
Catalog Code - Heavy DutyGA50U2006
Part Number - Open Type05P00620-0024
240V, 3-Phase Input, 3% AC Output Reactors [GA500 - AC Output Reactors]
Nominal HP1.5
Catalog Code - Normal DutyGA50U2006
Catalog Code - Heavy DutyGA50U2008
Part Number - Open Type05P00620-0024
240V, 3-Phase Input, 3% AC Output Reactors [GA500 - AC Output Reactors] (2)
Nominal HP2
Catalog Code - Normal DutyGA50U2008
Catalog Code - Heavy DutyGA50U2010
Part Number - Open Type05P00620-0024
240V, 1-Phase Input, 3% AC Output Reactors [GA501 - AC Output Reactors]
Nominal HP1
Catalog Code - Heavy DutyGA51UB006
Part Number - Open Type05P00620-0024
240V, 1-Phase Input, 3% AC Output Reactors [GA501 - AC Output Reactors] (2)
Nominal HP1.5
Catalog Code - Normal DutyGA51UB006
Part Number - Open Type05P00620-0024
240V, 3-Phase Input, 3% AC Output Reactors [GA501 - AC Output Reactors]
Nominal HP1
Catalog Code - Heavy DutyGA51U2006
Part Number - Open Type05P00620-0024
240V, 3-Phase Input, 3% AC Output Reactors [GA501 - AC Output Reactors] (2)
Nominal HP1.5
Catalog Code - Normal DutyGA51U2006
Part Number - Open Type05P00620-0024
240V, 3-Phase Input, 3% AC Output Reactors [GA501 - AC Output Reactors] (3)
Nominal HP2
Catalog Code - Heavy DutyGA51U2010
Part Number - Open Type05P00620-0024
230V, 3% AC Output Reactors
Nominal HP2
Catalog Code - Normal DutyGA80U2008...
Catalog Code - Heavy DutyGA80U2010...
Part Number - Open Type05P00620-0024
240V, 1-Phase Input, 3% AC Output Reactors [HV305 - AC Output Reactors]
Nominal HP1
Catalog Code - Heavy DutyHV35UB006
Part Number - Open Type05P00620-0024
240V, 1-Phase Input, 3% AC Output Reactors [HV305 - AC Output Reactors] (2)
Nominal HP1.5
Catalog Code - Normal DutyHV35UB006
Part Number - Open Type05P00620-0024
240V, 3-Phase Input, 3% AC Output Reactors [HV305 - AC Output Reactors]
Nominal HP1
Catalog Code - Heavy DutyHV35U2006
Part Number - Open Type05P00620-0024
240V, 3-Phase Input, 3% AC Output Reactors [HV305 - AC Output Reactors] (2)
Nominal HP1.5
Catalog Code - Normal DutyHV35U2006
Catalog Code - Heavy DutyHV35U2008
Part Number - Open Type05P00620-0024
240V, 3-Phase Input, 3% AC Output Reactors [HV305 - AC Output Reactors] (3)
Nominal HP2
Catalog Code - Normal DutyHV35U2008
Catalog Code - Heavy DutyHV35U2010
Part Number - Open Type05P00620-0024
iQpump1000 - Load Reactors
Nominal HP1.5
Nominal 3% Impedance - Reactor Rated Current (A)8
Nominal 3% Impedance - Inductance (μH)1500
Nominal 3% Impedance - Weight (lb)14
Drive Model NumberCIMR-PW2A0006
iQpump1000 - Load Reactors [iQpump1000 - Load Reactors]
Nominal HP2
Nominal 3% Impedance - Reactor Rated Current (A)8
Nominal 3% Impedance - Inductance (μH)1500
Nominal 3% Impedance - Weight (lb)14
Drive Model NumberCIMR-PW2A0008
J1000 Reactor Options
3% Enclosed Reactor - Dimensions (in.) - H8
3% Enclosed Reactor - Dimensions (in.) - L8
3% Enclosed Reactor - Dimensions (in.) - W6
5% Enclosed Reactor - Dimensions (in.) - H8
5% Enclosed Reactor - Dimensions (in.) - L8
5% Enclosed Reactor - Dimensions (in.) - W6
Drive Model Number CIMR-JU2A0006
5% Enclosed Reactor - Part Number05P00620-0028
J1000 Reactor Options [J1000 Reactor Options]
3% Enclosed Reactor - Dimensions (in.) - H8
3% Enclosed Reactor - Dimensions (in.) - L8
3% Enclosed Reactor - Dimensions (in.) - W6
5% Enclosed Reactor - Dimensions (in.) - H8
5% Enclosed Reactor - Dimensions (in.) - L8
5% Enclosed Reactor - Dimensions (in.) - W6
Drive Model Number CIMR-JU2A0010
5% Enclosed Reactor - Part Number05P00620-0028
P1000 Load Reactors
Nominal HP1.5
Nominal 3% Impedance - Reactor Rated Current (A)8
Nominal 3% Impedance - Inductance (μH)1500
Nominal 3% Impedance - Weight (lb)14
Drive Model NumberCIMR-PU2A0006
P1000 Load Reactors [P1000 Load Reactors]
Nominal HP2
Nominal 3% Impedance - Reactor Rated Current (A)8
Nominal 3% Impedance - Inductance (μH)1500
Nominal 3% Impedance - Weight (lb)14
Drive Model NumberCIMR-PU2A0008
V1000 Reactor Options
3% Enclosed Reactor - Dimensions (in.) - H8
3% Enclosed Reactor - Dimensions (in.) - L8
3% Enclosed Reactor - Dimensions (in.) - W6
5% Enclosed Reactor - Dimensions (in.) - H8
5% Enclosed Reactor - Dimensions (in.) - L8
5% Enclosed Reactor - Dimensions (in.) - W6
Drive Model Number CIMR-VUBA0006_AA
5% Enclosed Reactor - Part Number05P00620-0028
V1000 Reactor Options [V1000 Reactor Options]
3% Enclosed Reactor - Dimensions (in.) - H8
3% Enclosed Reactor - Dimensions (in.) - L8
3% Enclosed Reactor - Dimensions (in.) - W6
5% Enclosed Reactor - Dimensions (in.) - H8
5% Enclosed Reactor - Dimensions (in.) - L8
5% Enclosed Reactor - Dimensions (in.) - W6
Drive Model Number CIMR-VUBA0010_AA
5% Enclosed Reactor - Part Number05P00620-0028
V1000 Reactor Options [V1000 Reactor Options] (2)
3% Enclosed Reactor - Dimensions (in.) - H8
3% Enclosed Reactor - Dimensions (in.) - L8
3% Enclosed Reactor - Dimensions (in.) - W6
5% Enclosed Reactor - Dimensions (in.) - H8
5% Enclosed Reactor - Dimensions (in.) - L8
5% Enclosed Reactor - Dimensions (in.) - W6
Drive Model Number CIMR-VU2A0006_AA
5% Enclosed Reactor - Part Number05P00620-0028
V1000 Reactor Options [V1000 Reactor Options] (3)
3% Enclosed Reactor - Dimensions (in.) - H8
3% Enclosed Reactor - Dimensions (in.) - L8
3% Enclosed Reactor - Dimensions (in.) - W6
5% Enclosed Reactor - Dimensions (in.) - H8
5% Enclosed Reactor - Dimensions (in.) - L8
5% Enclosed Reactor - Dimensions (in.) - W6
Drive Model Number CIMR-VU2A0010_AA
5% Enclosed Reactor - Part Number05P00620-0028

Documentation & CAD

Files hosted by Yaskawa; links open the official document or download page. 3D CAD requires a free Yaskawa login.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs Yaskawa parts — new, refurbished, or exchange units with warranty.

Specifications compiled from official Yaskawa product documentation. Always confirm against the datasheet for your exact unit and revision.