IAC

Yaskawa 05P00620-0036

A1000 - Load Reactors

240V, 3-Phase Input, 3% Reactors | 480V, 3-Phase Input, 3% Reactors

Lifecycle & replacement

Lifecycle status not published

Yaskawa's published discontinuation lists (checked 2026-09-01) do not assign a lifecycle status to this part number.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Checked against: Yaskawa America Support By Product - Inverter Drives; Yaskawa America Support By Product - Servo Amplifiers; Yaskawa America Support By Product - Servomotors; Yaskawa America Support By Product - Machine Controllers; Yaskawa America Support By Product - PLC Controllers; Yaskawa America Support By Product - Spindle Drives; Yaskawa America Support By Product - Spindle Motors; Yaskawa product page carrying the verbatim definition of Legacy.

Technical specifications

200-240V, 3% Line/Load Reactors
Rated Input Voltage200-240V, 3-Phase
Nominal HP5
Nominal 3% Impedance - Reactor Rated Current (A)18
Nominal 3% Impedance - Inductance (μH)800
Nominal 3% Impedance - Weight (lb)16
Drive Model Number - Normal DutyCIMR-AU2A0018
Drive Model Number - Heavy DutyCIMR-AU2A0021
240V, 3-Phase Input, 3% AC Output Reactors
Nominal HP5
Catalog CodeFP65U2017
Part Number - Open Type05P00620-0136
G7 Reactor Options
Rated Output Current (Amps)12
3% Enclosed Reactor - Dimensions (in) - H8
3% Enclosed Reactor - Dimensions (in) - L8
3% Enclosed Reactor - Dimensions (in) - W6
5% Enclosed Reactor - Dimensions (in) - H8
5% Enclosed Reactor - Dimensions (in) - L8
5% Enclosed Reactor - Dimensions (in) - W6
Drive Model Number CIMR-G7U22P21
5% Enclosed Reactor - Part Number 05P00620-05P00620-0032
G7 Reactor Options [G7 Reactor Options]
Rated Output Current (Amps)18
3% Enclosed Reactor - Dimensions (in) - H13
3% Enclosed Reactor - Dimensions (in) - L13
3% Enclosed Reactor - Dimensions (in) - W13
5% Enclosed Reactor - Dimensions (in) - H8
5% Enclosed Reactor - Dimensions (in) - L8
5% Enclosed Reactor - Dimensions (in) - W6
Drive Model Number CIMR-G7U23P71
3% Enclosed Reactor - Part Number 05P00620-05P00620-0041
G7 Reactor Options [G7 Reactor Options] (2)
Rated Output Current (Amps)12
3% Enclosed Reactor - Dimensions (in) - H8
3% Enclosed Reactor - Dimensions (in) - L8
3% Enclosed Reactor - Dimensions (in) - W6
5% Enclosed Reactor - Dimensions (in) - H8
5% Enclosed Reactor - Dimensions (in) - L8
5% Enclosed Reactor - Dimensions (in) - W6
Drive Model Number CIMR-G7U22P21
5% Enclosed Reactor - Part Number 05P00620-05P00620-0037
G7 Reactor Options [G7 Reactor Options] (3)
Rated Output Current (Amps)18
3% Enclosed Reactor - Dimensions (in) - H8
3% Enclosed Reactor - Dimensions (in) - L8
3% Enclosed Reactor - Dimensions (in) - W6
5% Enclosed Reactor - Dimensions (in) - H8
5% Enclosed Reactor - Dimensions (in) - L8
5% Enclosed Reactor - Dimensions (in) - W6
Drive Model Number CIMR-G7U23P71
5% Enclosed Reactor - Part Number 05P00620-05P00620-0037
240V, 1-Phase Input, 3% AC Output Reactors
Nominal HP5
Catalog Code - Heavy DutyGA50UB018
Part Number - Open Type05P00620-0136
240V, 3-Phase Input, 3% AC Output Reactors [GA500 - AC Output Reactors]
Nominal HP5
Catalog Code - Normal DutyGA50U2018
Catalog Code - Heavy DutyGA50U2021
Part Number - Open Type05P00620-0136
240V, 1-Phase Input, 3% AC Output Reactors [GA501 - AC Output Reactors]
Nominal HP5
Catalog Code - Heavy DutyGA51UB018
Part Number - Open Type05P00620-0136
240V, 3-Phase Input, 3% AC Output Reactors [GA501 - AC Output Reactors]
Nominal HP5
Catalog Code - Heavy DutyGA51U2021
Part Number - Open Type05P00620-0136
230V, 3% AC Output Reactors
Nominal HP5
Catalog Code - Normal DutyGA80U2018...
Catalog Code - Heavy DutyGA80U2021...
Part Number - Open Type05P00620-0136
240V, 1-Phase Input, 3% AC Output Reactors [HV305 - AC Output Reactors]
Nominal HP5
Catalog Code - Heavy DutyHV35UB018
Part Number - Open Type05P00620-0136
240V, 3-Phase Input, 3% AC Output Reactors [HV305 - AC Output Reactors]
Nominal HP5
Catalog Code - Normal DutyHV35U2018
Catalog Code - Heavy DutyHV35U2021
Part Number - Open Type05P00620-0136
iQpump1000 - Load Reactors
Nominal HP5
Nominal 3% Impedance - Reactor Rated Current (A)18
Nominal 3% Impedance - Inductance (μH)800
Nominal 3% Impedance - Weight (lb)16
Drive Model NumberCIMR-PW2A0018
240V, 3-Phase Input, 3% AC Output Reactors [iQpump605 - AC Output Reactors]
Nominal HP5
Catalog CodeWM65W2017
Part Number - Open Type05P00620-0136
J1000 Reactor Options
3% Enclosed Reactor - Dimensions (in.) - H8
3% Enclosed Reactor - Dimensions (in.) - L8
3% Enclosed Reactor - Dimensions (in.) - W6
5% Enclosed Reactor - Dimensions (in.) - H8
5% Enclosed Reactor - Dimensions (in.) - L8
5% Enclosed Reactor - Dimensions (in.) - W6
Drive Model Number CIMR-JU2A0020
5% Enclosed Reactor - Part Number05P00620-0037
P1000 Load Reactors
Nominal HP5
Nominal 3% Impedance - Reactor Rated Current (A)18
Nominal 3% Impedance - Inductance (μH)800
Nominal 3% Impedance - Weight (lb)16
Drive Model NumberCIMR-PU2A0018
V1000 Reactor Options
3% Enclosed Reactor - Dimensions (in.) - H8
3% Enclosed Reactor - Dimensions (in.) - L8
3% Enclosed Reactor - Dimensions (in.) - W6
5% Enclosed Reactor - Dimensions (in.) - H8
5% Enclosed Reactor - Dimensions (in.) - L8
5% Enclosed Reactor - Dimensions (in.) - W6
Drive Model Number CIMR-VUBA0018_AA
5% Enclosed Reactor - Part Number05P00620-0037
V1000 Reactor Options [V1000 Reactor Options]
3% Enclosed Reactor - Dimensions (in.) - H8
3% Enclosed Reactor - Dimensions (in.) - L8
3% Enclosed Reactor - Dimensions (in.) - W6
5% Enclosed Reactor - Dimensions (in.) - H8
5% Enclosed Reactor - Dimensions (in.) - L8
5% Enclosed Reactor - Dimensions (in.) - W6
Drive Model Number CIMR-VU2A0020_AA
5% Enclosed Reactor - Part Number05P00620-0037

Documentation & CAD

Files hosted by Yaskawa; links open the official document or download page. 3D CAD requires a free Yaskawa login.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs Yaskawa parts — new, refurbished, or exchange units with warranty.

Specifications compiled from official Yaskawa product documentation. Always confirm against the datasheet for your exact unit and revision.