Yaskawa 05P00620-0047
A1000 - Load Reactors
240V, 3-Phase Input, 3% Reactors | 480V, 3-Phase Input, 3% Reactors
Lifecycle & replacement
Yaskawa's published discontinuation lists (checked 2026-09-01) do not assign a lifecycle status to this part number.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Checked against: Yaskawa America Support By Product - Inverter Drives; Yaskawa America Support By Product - Servo Amplifiers; Yaskawa America Support By Product - Servomotors; Yaskawa America Support By Product - Machine Controllers; Yaskawa America Support By Product - PLC Controllers; Yaskawa America Support By Product - Spindle Drives; Yaskawa America Support By Product - Spindle Motors; Yaskawa product page carrying the verbatim definition of Legacy.
Technical specifications
200-240V, 5% Line/Load Reactors
| Rated Input Voltage | 200-240V, 3-Phase |
| Nominal HP | 10 |
| Nominal 5% Impedance - Reactor Rated Current (A) | 35 |
| Nominal 5% Impedance - Inductance (μH) | 800 |
| Nominal 5% Impedance - Weight (lb) | 34 |
| Drive Model Number - Normal Duty | CIMR-AU2A0030 |
| Drive Model Number - Heavy Duty | CIMR-AU2A0040 |
380-480V, 3% Line/Load Reactors
| Rated Input Voltage | 380-480V, 3-Phase |
| Nominal HP | 20 |
| Nominal 3% Impedance - Reactor Rated Current (A) | 35 |
| Nominal 3% Impedance - Inductance (μH) | 800 |
| Nominal 3% Impedance - Weight (lb) | 34 |
| Drive Model Number - Normal Duty | CIMR-AU4A0031 |
| Drive Model Number - Heavy Duty | CIMR-AU4A0038 |
380-480V, 3% Line/Load Reactors [A1000 - Load Reactors]
| Rated Input Voltage | 380-480V, 3-Phase |
| Nominal HP | 25 |
| Nominal 3% Impedance - Reactor Rated Current (A) | 35 |
| Nominal 3% Impedance - Inductance (μH) | 800 |
| Nominal 3% Impedance - Weight (lb) | 34 |
| Drive Model Number - Normal Duty | CIMR-AU4A0038 |
| Drive Model Number - Heavy Duty | CIMR-AU4A0044 |
500-600V, 3% Line/Load Reactors
| Rated Input Voltage | 500-600V, 3-Phase |
| Nominal HP | 30 |
| Nominal 3% Impedance - Reactor Rated Current (A) | 35 |
| Nominal 3% Impedance - Inductance (μH) | 800 |
| Nominal 3% Impedance - Weight (lb) | 34 |
| Drive Model Number - Normal Duty | CIMR-AU5A0032 |
500-600C, 5% Line/Load Reactors
| Rated Input Voltage | 500-600V, 3-Phase |
| Nominal HP | 30 |
| Nominal 5% Impedance - Reactor Rated Current (A) | 35 |
| Nominal 5% Impedance - Inductance (μH) | 800 |
| Nominal 5% Impedance - Weight (lb) | 34 |
| Drive Model Number - Heavy Duty | CIMR-AU5A0041 1 |
480V, 3-Phase Input, 3% AC Output Reactors
| Nominal HP | 20 |
| Catalog Code | FP65U4027 |
| Part Number - Open Type | 05P00620-0139 |
480V, 3-Phase Input, 3% AC Output Reactors [FP605 - AC Output Reactors]
| Nominal HP | 25 |
| Catalog Code | FP65U4034 |
| Part Number - Open Type | 05P00620-0139 |
G7 Reactor Options
| Rated Output Current (Amps) | 27 |
| 3% Enclosed Reactor - Dimensions (in) - H | 13 |
| 3% Enclosed Reactor - Dimensions (in) - L | 13 |
| 3% Enclosed Reactor - Dimensions (in) - W | 13 |
| 5% Enclosed Reactor - Dimensions (in) - H | 13 |
| 5% Enclosed Reactor - Dimensions (in) - L | 13 |
| 5% Enclosed Reactor - Dimensions (in) - W | 13 |
| Drive Model Number CIMR-G7U | 25P51 |
| 3% Enclosed Reactor - Part Number 05P00620- | 05P00620-0046 |
G7 Reactor Options [G7 Reactor Options]
| Rated Output Current (Amps) | 27 |
| 3% Enclosed Reactor - Dimensions (in) - H | 13 |
| 3% Enclosed Reactor - Dimensions (in) - L | 13 |
| 3% Enclosed Reactor - Dimensions (in) - W | 13 |
| 5% Enclosed Reactor - Dimensions (in) - H | 13 |
| 5% Enclosed Reactor - Dimensions (in) - L | 13 |
| 5% Enclosed Reactor - Dimensions (in) - W | 13 |
| Drive Model Number CIMR-G7U | 40111 |
| 5% Enclosed Reactor - Part Number 05P00620- | 05P00620-0048 |
480V, 3-Phase Input, 3% AC Output Reactors [GA500 - AC Output Reactors]
| Nominal HP | 20 |
| Catalog Code - Normal Duty | GA50U4031 |
| Catalog Code - Heavy Duty | GA50U4038 |
| Part Number - Open Type | 05P00620-0139 |
480V, 3-Phase Input, 3% AC Output Reactors [GA500 - AC Output Reactors] (2)
| Nominal HP | 25 |
| Catalog Code - Normal Duty | GA50U4038 |
| Catalog Code - Heavy Duty | GA50U4044 |
| Part Number - Open Type | 05P00620-0139 |
480V, 3-Phase Input, 3% AC Output Reactors [GA501 - AC Output Reactors]
| Nominal HP | 20 |
| Catalog Code - Normal Duty | GA51U4031 |
| Catalog Code - Heavy Duty | GA51U4038 |
| Part Number - Open Type | 05P00620-0139 |
480V, 3-Phase Input, 3% AC Output Reactors [GA501 - AC Output Reactors] (2)
| Nominal HP | 25 |
| Catalog Code - Normal Duty | GA51U4038 |
| Catalog Code - Heavy Duty | GA51U4044 |
| Part Number - Open Type | 05P00620-0139 |
460V, 3% AC Output Reactors
| Nominal HP | 20 |
| Catalog Code - Normal Duty | GA80U4031... |
| Catalog Code - Heavy Duty | GA80U4038... |
| Part Number - Open Type | 05P00620-0139 |
460V, 3% AC Output Reactors [GA800 - AC Output Reactors]
| Nominal HP | 25 |
| Catalog Code - Normal Duty | GA80U4038... |
| Catalog Code - Heavy Duty | GA80U4044... |
| Part Number - Open Type | 05P00620-0139 |
480V, 3-Phase Input, 3% AC Output Reactors [HV305 - AC Output Reactors]
| Nominal HP | 20 |
| Catalog Code - Normal Duty | HV35U4031 |
| Catalog Code - Heavy Duty | HV35U4038 |
| Part Number - Open Type | 05P00620-0139 |
480V, 3-Phase Input, 3% AC Output Reactors [HV305 - AC Output Reactors] (2)
| Nominal HP | 25 |
| Catalog Code - Normal Duty | HV35U4038 |
| Part Number - Open Type | 05P00620-0139 |
iQpump1000 - Load Reactors
| Nominal HP | 10 |
| Nominal 5% Impedance - Reactor Rated Current (A) | 35 |
| Nominal 5% Impedance - Inductance (μH) | 800 |
| Nominal 5% Impedance - Weight (lb) | 34 |
| Drive Model Number | CIMR-PW2A0030 |
iQpump1000 - Load Reactors [iQpump1000 - Load Reactors]
| Nominal HP | 20 |
| Nominal 3% Impedance - Reactor Rated Current (A) | 35 |
| Nominal 3% Impedance - Inductance (μH) | 800 |
| Nominal 3% Impedance - Weight (lb) | 34 |
| Drive Model Number | CIMR-PW4A0031 |
iQpump1000 - Load Reactors [iQpump1000 - Load Reactors] (2)
| Nominal HP | 25 |
| Nominal 3% Impedance - Reactor Rated Current (A) | 35 |
| Nominal 3% Impedance - Inductance (μH) | 800 |
| Nominal 3% Impedance - Weight (lb) | 34 |
| Drive Model Number | CIMR-PW4A0038 |
iQpump1000 - Load Reactors [iQpump1000 - Load Reactors] (3)
| Nominal HP | 30 |
| Nominal 3% Impedance - Reactor Rated Current (A) | 35 |
| Nominal 3% Impedance - Inductance (μH) | 800 |
| Nominal 3% Impedance - Weight (lb) | 34 |
| Drive Model Number | CIMR-PW5A0032 |
480V, 3-Phase Input, 3% AC Output Reactors [iQpump605 - AC Output Reactors]
| Nominal HP | 20 |
| Catalog Code | WM65W4027 |
| Part Number - Open Type | 05P00620-0139 |
480V, 3-Phase Input, 3% AC Output Reactors [iQpump605 - AC Output Reactors] (2)
| Nominal HP | 25 |
| Catalog Code | WM65W4034 |
| Part Number - Open Type | 05P00620-0139 |
P1000 Load Reactors
| Nominal HP | 10 |
| Nominal 5% Impedance - Reactor Rated Current (A) | 35 |
| Nominal 5% Impedance - Inductance (μH) | 800 |
| Nominal 5% Impedance - Weight (lb) | 34 |
| Drive Model Number | CIMR-PU2A0030 |
P1000 Load Reactors [P1000 Load Reactors]
| Nominal HP | 20 |
| Nominal 3% Impedance - Reactor Rated Current (A) | 35 |
| Nominal 3% Impedance - Inductance (μH) | 800 |
| Nominal 3% Impedance - Weight (lb) | 34 |
| Drive Model Number | CIMR-PU4A0031 |
P1000 Load Reactors [P1000 Load Reactors] (2)
| Nominal HP | 25 |
| Nominal 3% Impedance - Reactor Rated Current (A) | 35 |
| Nominal 3% Impedance - Inductance (μH) | 800 |
| Nominal 3% Impedance - Weight (lb) | 34 |
| Drive Model Number | CIMR-PU4A0038 |
P1000 Load Reactors [P1000 Load Reactors] (3)
| Nominal HP | 30 |
| Nominal 3% Impedance - Reactor Rated Current (A) | 35 |
| Nominal 3% Impedance - Inductance (μH) | 800 |
| Nominal 3% Impedance - Weight (lb) | 34 |
| Drive Model Number | CIMR-PU5A0032 |
V1000 Reactor Options
| 3% Enclosed Reactor - Dimensions (in.) - H | 13 |
| 3% Enclosed Reactor - Dimensions (in.) - L | 13 |
| 3% Enclosed Reactor - Dimensions (in.) - W | 13 |
| 5% Enclosed Reactor - Dimensions (in.) - H | 13 |
| 5% Enclosed Reactor - Dimensions (in.) - L | 13 |
| 5% Enclosed Reactor - Dimensions (in.) - W | 13 |
| Drive Model Number CIMR-VU | 2A0040_AA |
| 3% Enclosed Reactor - Part Number | 05P00620-0046 |
V1000 Reactor Options [V1000 Reactor Options]
| 3% Enclosed Reactor - Dimensions (in.) - H | 13 |
| 3% Enclosed Reactor - Dimensions (in.) - L | 13 |
| 3% Enclosed Reactor - Dimensions (in.) - W | 13 |
| 5% Enclosed Reactor - Dimensions (in.) - H | 13 |
| 5% Enclosed Reactor - Dimensions (in.) - L | 13 |
| 5% Enclosed Reactor - Dimensions (in.) - W | 13 |
| Drive Model Number CIMR-VU | 4A0023_AA |
| 5% Enclosed Reactor - Part Number | 05P00620-0048 |
V1000 Reactor Options [V1000 Reactor Options] (2)
| 3% Enclosed Reactor - Dimensions (in.) - H | 13 |
| 3% Enclosed Reactor - Dimensions (in.) - L | 13 |
| 3% Enclosed Reactor - Dimensions (in.) - W | 13 |
| 5% Enclosed Reactor - Dimensions (in.) - H | 13 |
| 5% Enclosed Reactor - Dimensions (in.) - L | 13 |
| 5% Enclosed Reactor - Dimensions (in.) - W | 13 |
| Drive Model Number CIMR-VU | 4A0031_AA |
| 5% Enclosed Reactor - Part Number | 05P00620-0048 |
Documentation & CAD
Files hosted by Yaskawa; links open the official document or download page. 3D CAD requires a free Yaskawa login.
Datasheets & catalogs
Manuals
- Tech Manual
- Arc Flash and PPE Manual Supplement
- Product Transition Guide A1000 to GA800
- Back-up Capacitor Unit for Momentary Power Loss - Option Installation Manual
- FP605 Installation & Primary Operation
- FP605 Installation & Primary Operation (TOEPYAISUP22)
- FP605 Installation & Primary Operation (EZZ024329)
- FP605 Drive AC Drive for Industrial Fan and Pump Applications Technical Reference
- FP605 Drive AC Drive for Industrial Fan and Pump Applications Technical Reference (TOEPYAISUP22)
- FP605 Drive AC Drive for Industrial Fan and Pump Applications Technical Reference (EZZ024352)
- FP605 with Main Switch Installation & Primary Operation
- FP605 Programming Manual
- + 128 more on the official site
2D drawings
ECAD / configuration files
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs Yaskawa parts — new, refurbished, or exchange units with warranty.
Specifications compiled from official Yaskawa product documentation. Always confirm against the datasheet for your exact unit and revision.