IAC

Yaskawa 05P00620-0058

A1000 - Load Reactors

240V, 3-Phase Input, 3% Reactors | 480V, 3-Phase Input, 3% Reactors

Lifecycle & replacement

Lifecycle status not published

Yaskawa's published discontinuation lists (checked 2026-09-01) do not assign a lifecycle status to this part number.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Checked against: Yaskawa America Support By Product - Inverter Drives; Yaskawa America Support By Product - Servo Amplifiers; Yaskawa America Support By Product - Servomotors; Yaskawa America Support By Product - Machine Controllers; Yaskawa America Support By Product - PLC Controllers; Yaskawa America Support By Product - Spindle Drives; Yaskawa America Support By Product - Spindle Motors; Yaskawa product page carrying the verbatim definition of Legacy.

Technical specifications

200-240V, 3% Line/Load Reactors
Rated Input Voltage200-240V, 3-Phase
Nominal HP25
Nominal 3% Impedance - Reactor Rated Current (A)80
Nominal 3% Impedance - Inductance (μH)200
Nominal 3% Impedance - Weight (lb)43
Drive Model Number - Normal DutyCIMR-AU2A0069
Drive Model Number - Heavy DutyCIMR-AU2A0081
200-240V, 3% Line/Load Reactors [A1000 - Load Reactors]
Rated Input Voltage200-240V, 3-Phase
Nominal HP30
Nominal 3% Impedance - Reactor Rated Current (A)80
Nominal 3% Impedance - Inductance (μH)200
Nominal 3% Impedance - Weight (lb)43
Drive Model Number - Normal DutyCIMR-AU2A0081
200-240V, 3% Line/Load Reactors [A1000 - Load Reactors] (2)
Rated Input Voltage200-240V, 3-Phase
Nominal HP30
Nominal 3% Impedance - Reactor Rated Current (A)80
Nominal 3% Impedance - Inductance (μH)200
Nominal 3% Impedance - Weight (lb)43
Drive Model Number - Heavy DutyCIMR-AU2A0110 1
200-240V, 5% Line/Load Reactors
Rated Input Voltage200-240V, 3-Phase
Nominal HP30
Nominal 5% Impedance - Reactor Rated Current (A)80
Nominal 5% Impedance - Inductance (μH)200
Nominal 5% Impedance - Weight (lb)43
Drive Model Number - Heavy DutyCIMR-AU2A0110 1
380-480V, 3% Line/Load Reactors
Rated Input Voltage380-480V, 3-Phase
Nominal HP50
Nominal 3% Impedance - Reactor Rated Current (A)80
Nominal 3% Impedance - Inductance (μH)200
Nominal 3% Impedance - Weight (lb)43
Drive Model Number - Normal DutyCIMR-AU4A0072 1
Drive Model Number - Heavy DutyCIMR-AU4A0088 1
380-480V, 3% Line/Load Reactors [A1000 - Load Reactors]
Rated Input Voltage380-480V, 3-Phase
Nominal HP60
Nominal 3% Impedance - Reactor Rated Current (A)80
Nominal 3% Impedance - Inductance (μH)200
Nominal 3% Impedance - Weight (lb)43
Drive Model Number - Normal DutyCIMR-AU4A0088 1
Drive Model Number - Heavy DutyCIMR-AU4A0088 1
500-600V, 3% Line/Load Reactors
Rated Input Voltage500-600V, 3-Phase
Nominal HP60
Nominal 3% Impedance - Reactor Rated Current (A)80
Nominal 3% Impedance - Inductance (μH)200
Nominal 3% Impedance - Weight (lb)43
Drive Model Number - Normal DutyCIMR-AU5A0062 1
Drive Model Number - Heavy DutyCIMR-AU5A0077 1
500-600V, 3% Line/Load Reactors [A1000 - Load Reactors]
Rated Input Voltage500-600V, 3-Phase
Nominal HP75
Nominal 3% Impedance - Reactor Rated Current (A)80
Nominal 3% Impedance - Inductance (μH)200
Nominal 3% Impedance - Weight (lb)43
Drive Model Number - Normal DutyCIMR-AU5A0077 1
Drive Model Number - Heavy DutyCIMR-AU5A0099 1
240V, 3-Phase Input, 3% AC Output Reactors
Nominal HP20
Catalog CodeFP65U2059
Part Number - Open Type05P00620-0143
G7 Reactor Options
Rated Output Current (Amps)66
3% Enclosed Reactor - Dimensions (in) - H13
3% Enclosed Reactor - Dimensions (in) - L13
3% Enclosed Reactor - Dimensions (in) - W13
5% Enclosed Reactor - Dimensions (in) - H13
5% Enclosed Reactor - Dimensions (in) - L13
5% Enclosed Reactor - Dimensions (in) - W13
Drive Model Number CIMR-G7U20151
5% Enclosed Reactor - Part Number 05P00620-05P00620-0059
240V, 3-Phase Input, 3% AC Output Reactors [GA500 - AC Output Reactors]
Nominal HP25
Catalog Code - Normal DutyGA50U2070
Catalog Code - Heavy DutyGA50U2082
Part Number - Open Type05P00620-0143
240V, 3-Phase Input, 3% AC Output Reactors [GA501 - AC Output Reactors]
Nominal HP25
Catalog Code - Normal DutyGA51U2070
Catalog Code - Heavy DutyGA51U2082
Part Number - Open Type05P00620-0143
230V, 3% AC Output Reactors
Nominal HP20
Catalog Code - Normal DutyGA80U2056...
Catalog Code - Heavy DutyGA80U2070...
Part Number - Open Type05P00620-0143
230V, 3% AC Output Reactors [GA800 - AC Output Reactors]
Nominal HP25
Catalog Code - Normal DutyGA80U2070...
Catalog Code - Heavy DutyGA80U2082...
Part Number - Open Type05P00620-0143
230V, 3% AC Output Reactors [GA800 - AC Output Reactors] (2)
Nominal HP30
Catalog Code - Normal DutyGA80U2082...
Catalog Code - Heavy DutyGA80U2110…
Part Number - Open Type05P00620-0143
240V, 3-Phase Input, 3% AC Output Reactors [HV305 - AC Output Reactors]
Nominal HP25
Catalog Code - Normal DutyHV35U2070
Catalog Code - Heavy DutyHV35U2082
Part Number - Open Type05P00620-0143
iQpump1000 - Load Reactors
Nominal HP25
Nominal 3% Impedance - Reactor Rated Current (A)80
Nominal 3% Impedance - Inductance (μH)200
Nominal 3% Impedance - Weight (lb)43
Drive Model NumberCIMR-PW2A0069
iQpump1000 - Load Reactors [iQpump1000 - Load Reactors]
Nominal HP30
Nominal 3% Impedance - Reactor Rated Current (A)80
Nominal 3% Impedance - Inductance (μH)200
Nominal 3% Impedance - Weight (lb)43
Drive Model NumberCIMR-PW2A0081
iQpump1000 - Load Reactors [iQpump1000 - Load Reactors] (2)
Nominal HP50
Nominal 3% Impedance - Reactor Rated Current (A)80
Nominal 3% Impedance - Inductance (μH)200
Nominal 3% Impedance - Weight (lb)43
Drive Model NumberCIMR-PW4A0072 1
iQpump1000 - Load Reactors [iQpump1000 - Load Reactors] (3)
Nominal HP60
Nominal 3% Impedance - Reactor Rated Current (A)80
Nominal 3% Impedance - Inductance (μH)200
Nominal 3% Impedance - Weight (lb)43
Drive Model NumberCIMR-PW4A0088 1
iQpump1000 - Load Reactors [iQpump1000 - Load Reactors] (4)
Nominal HP60
Nominal 3% Impedance - Reactor Rated Current (A)80
Nominal 3% Impedance - Inductance (μH)200
Nominal 3% Impedance - Weight (lb)43
Drive Model NumberCIMR-PW5A0062 1
iQpump1000 - Load Reactors [iQpump1000 - Load Reactors] (5)
Nominal HP75
Nominal 3% Impedance - Reactor Rated Current (A)80
Nominal 3% Impedance - Inductance (μH)200
Nominal 3% Impedance - Weight (lb)43
Drive Model NumberCIMR-PW5A0077 1
240V, 3-Phase Input, 3% AC Output Reactors [iQpump605 - AC Output Reactors]
Nominal HP20
Catalog CodeWM65W2059
Part Number - Open Type05P00620-0143
P1000 Load Reactors
Nominal HP25
Nominal 3% Impedance - Reactor Rated Current (A)80
Nominal 3% Impedance - Inductance (μH)200
Nominal 3% Impedance - Weight (lb)43
Drive Model NumberCIMR-PU2A0069
P1000 Load Reactors [P1000 Load Reactors]
Nominal HP30
Nominal 3% Impedance - Reactor Rated Current (A)80
Nominal 3% Impedance - Inductance (μH)200
Nominal 3% Impedance - Weight (lb)43
Drive Model NumberCIMR-PU2A0081
P1000 Load Reactors [P1000 Load Reactors] (2)
Nominal HP50
Nominal 3% Impedance - Reactor Rated Current (A)80
Nominal 3% Impedance - Inductance (μH)200
Nominal 3% Impedance - Weight (lb)43
Drive Model NumberCIMR-PU4A0072
P1000 Load Reactors [P1000 Load Reactors] (3)
Nominal HP60
Nominal 3% Impedance - Reactor Rated Current (A)80
Nominal 3% Impedance - Inductance (μH)200
Nominal 3% Impedance - Weight (lb)43
Drive Model NumberCIMR-PU4A0088
P1000 Load Reactors [P1000 Load Reactors] (4)
Nominal HP60
Nominal 3% Impedance - Reactor Rated Current (A)80
Nominal 3% Impedance - Inductance (μH)200
Nominal 3% Impedance - Weight (lb)43
Drive Model NumberCIMR-PU5A0062
P1000 Load Reactors [P1000 Load Reactors] (5)
Nominal HP75
Nominal 3% Impedance - Reactor Rated Current (A)80
Nominal 3% Impedance - Inductance (μH)200
Nominal 3% Impedance - Weight (lb)43
Drive Model NumberCIMR-PU5A0077
V1000 Reactor Options
3% Enclosed Reactor - Dimensions (in.) - H13
3% Enclosed Reactor - Dimensions (in.) - L13
3% Enclosed Reactor - Dimensions (in.) - W13
5% Enclosed Reactor - Dimensions (in.) - H13
5% Enclosed Reactor - Dimensions (in.) - L13
5% Enclosed Reactor - Dimensions (in.) - W13
Drive Model Number CIMR-VU2A0069_AA
5% Enclosed Reactor - Part Number05P00620-0059

Documentation & CAD

Files hosted by Yaskawa; links open the official document or download page. 3D CAD requires a free Yaskawa login.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs Yaskawa parts — new, refurbished, or exchange units with warranty.

Specifications compiled from official Yaskawa product documentation. Always confirm against the datasheet for your exact unit and revision.