B&R 0ACS100A.90-1
Accelerometer, nominal sensitivity 100 mV/g, side exit
Lifecycle & replacement
Lifecycle status not indexed
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
Sensor properties
| Natural resonance (installed) | 30 kHz (nominal) |
| Sensitivity | 100 mV/g ±10% nominal 80 Hz at 22°C |
| Frequency response | 2 Hz (120 cpm) to 10 kHz (600 kcpm) ±5% 1.5 Hz (90 cpm) to 12 kHz (720 kcpm) ±10% 0.8 Hz (48 cpm) to 15 kHz (900 kcpm) ±3 dB |
| Isolation | Isolated base |
| Measurement range | ±50 g |
| Cross-sensitivity | <5% |
Electrical properties
| Electrical disturbances | Max. 0.1 mg |
| Broadband resolution | 0.2 mg (200 µg) over 1 Hz to 15 kHz |
| Spectral noise | 10 Hz to 10 µg/Hz 100 Hz to 4 µg/Hz 1 kHz to 3 µg/Hz |
| Current range | 0.5 to 8 mA |
| Bias voltage | 10 to 12 VDC |
| Settling time | 2 s |
| Output impedance | Max. 200 Ω |
| Housing isolation | >10⁸ Ω at 500 V |
Operating conditions
| Degree of protection per EN 60529 | IP67 |
Ambient conditions
| Temperature / Operation | -55 to 140°C |
| Max. shock resistance | 5000 g |
| Emitted interferences | EN 61000-6-4:2001 |
| Immunity to interference | EN 61000-6-2:1999 |
Mechanical properties
| Housing / Material | Stainless steel |
| Installation | M8 x 1.25 x 33 mm screw, included in delivery |
| Weight | 170 g |
| Measurement element | PZT piezoelectric crystal (lead zirconate titanate) |
| Measurement execution | Compressed |
| Tightening torque | 8 Nm |
| Connectors | M12 |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.