IAC

Siemens 1FK7044-4CF71-1RH0

SIMOTICS S 1FK7 High Dynamic Synchronous Servo Motor

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for Siemens part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

Replacing or upgrading a servo component?

Servo amplifiers, motors, encoders and cables are matched sets. If this part is no longer available in its original form, the manufacturer's newer generation usually will not pair with the rest of the axis, so an upgrade normally covers the drive, motor and cables together. Send us the nameplate details and we will confirm availability of an exact spare or scope a compatible upgrade.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Part number breakdown

Decoded from SIMOTICS S-1FK7 G2 synchronous motors Configuration Manual, Edition 02/2018 (6SN1197-0AD16-0BP5), 2.5 Selection based on the article number, p.28, 29, 30. Codes the document does not list are shown as not documented.

  • Frame size / shaft height (positions 5-6)
    04
    SH 48
    shaftHeightMm: 48
    Source: 6SN1197-0AD16-0BP5 p.28
  • Overall length (position 7)
    4
    Overall length code 4
    Source: 6SN1197-0AD16-0BP5 p.28
  • Feature (position 8)
    4
    High Dynamic
    Source: 6SN1197-0AD16-0BP5 p.28
  • Cooling (position 9)
    C
    Natural cooling
    Source: 6SN1197-0AD16-0BP5 p.28
  • Rated speed, 3 AC 380 V ... 480 V (position 10)
    F
    3,000 rpm
    ratedSpeedRpm: 3000
    Source: 6SN1197-0AD16-0BP5 p.28
  • DC-link voltage (position 11)
    7
    510 V ... 720 V
    Source: 6SN1197-0AD16-0BP5 p.28
  • Type of construction (position 12)
    1
    IM B5 with a KTY84-130 or Pt1000 temperature sensor (see Chapter "Thermal motor protection")
    Source: 6SN1197-0AD16-0BP5 p.28
  • Connector outlet direction (position 13)
    1
    Plug connector sizes 1 and 1.5; connector can be rotated
    Source: 6SN1197-0AD16-0BP5 p.28
  • Encoder (position 14)
    R
    AM20DQI (with DRIVE-CLiQ)
    Source: 6SN1197-0AD16-0BP5 p.28, 29
  • Shaft extension / accuracy / holding brake (position 15)
    H
    Plain shaft, tolerance N, with holding brake
    brake: holding brake
    Source: 6SN1197-0AD16-0BP5 p.29
  • Vibration severity grade / degree of protection (position 16)
    0
    Vibration severity grade A, IP64
    Source: 6SN1197-0AD16-0BP5 p.29

Official description

SIMOTICS S Synchronous motor 1FK7-HD PN=1.2kW; UDC=600V M0=4.5Nm (100K); NN=3000rpm; Naturally cooled FRAME SIZE IMB 5 (IM V1, IM V3) FLANGE 1 POWER CONNECTOR ROTATABLE ABSOLUTE ENCODER 20 BIT + 12 BIT MULTITURN WITH DRIVE-CLIQ INTERFACE (ENCODER AM20DQI) PLAIN SHAFT, TOLERANCE N; WITH HOLDING BRAKE Degree of protection IP64

Source: Siemens catalog short-text.

Specifications

designationSIMOTICS S-1FK7 High Dynamic synchronous motor 1FK7044 (natural cooling, 3000 rpm)
staticTorqueNm4.5
ratedTorqueNm3.7
ratedSpeedRpm3000
ratedCurrentA3.45
ratedPowerKw1.2
stallCurrentA4
efficiencyPct91
polePairs3
shaftHeightMm48
rotorInertiaKgcm21.26
weightKg7.4
dcLinkVoltage510 ... 720 V DC
coolingnatural cooling

Source: Siemens catalog nc-62.pdf (family ordering-data row).

Fault codes for this servo motor (937)

  • A01006Firmware update for DRIVE-CLiQ component required
  • A01007POWER ON for DRIVE-CLiQ component required
  • A01009CU: Control module overtemperature
  • A01013CU: Fan operating time reached or exceeded
  • A01016Firmware changed
  • A01017Component lists changed
  • A01020Writing to RAM disk unsuccessful
  • A01032ACX: all parameters must be saved
  • A01035ACX: Parameter back-up file corrupted
  • A01045CU: Configuring data invalid
  • A01049CU: It is not possible to write to file
  • A01064CU: Internal error (CRC)
  • A01069Parameter backup and device incompatible
  • A01073POWER ON required for backup copy on memory card
  • A01097NTP server cannot be accessed
  • A01099UTC synchronization tolerance violated
  • A01100CU: Memory card withdrawn
  • A01223CU: Sampling time inconsistent
  • A01224CU: Pulse frequency inconsistent
  • A01251CU: CU-EEPROM incorrect read-write data
  • A01256CU: Option Board EEPROM read-write data error
  • A01276Hardware description not fully compatible
  • A01302Error in the component trace
  • A01304(F) Firmware version of DRIVE-CLiQ component is not up-to-date
  • A01306Firmware of the DRIVE-CLiQ component being updated
  • A01314Topology: Component must not be present
  • A01317(N) Deactivated component again present
  • A01318BICO: Deactivated interconnections present
  • A01319Inserted component not initialized
  • A01320Topology: Drive object number does not exist in configuration
  • A01321Topology: Drive object number does not exist in configuration
  • A01322Topology: Drive object number present twice in configuration
  • A01323Topology: More than two partial lists created
  • A01324Topology: Dummy drive object number incorrectly created
  • A01381Topology: power unit incorrectly inserted
  • A01382Topology: Sensor Module incorrectly inserted
  • A01383Topology: Terminal Module incorrectly inserted
  • A01384Topology: DRIVE-CLiQ Hub Module incorrectly inserted
  • A01385Topology: Controller Extension incorrectly inserted
  • A01386Topology: DRIVE-CLiQ component incorrectly inserted
  • A01389Topology: Motor with DRIVE-CLiQ incorrectly inserted
  • A01416Topology: Component additionally inserted
  • A01420Topology: Component different
  • A01425Topology: Serial number different
  • A01428Topology: Incorrect connection used
  • A01481Topology: Motor Module not connected
  • A01482Topology: Sensor Module not connected
  • A01483Topology: Terminal Module not connected
  • A01484Topology: DRIVE-CLiQ Hub Module not connected
  • A01485Topology: Controller Extension not connected
  • A01486Topology: DRIVE-CLiQ component not connected
  • A01487Topology: Option slot component not inserted
  • A01489Topology: motor with DRIVE-CLiQ not connected
  • A01507BICO: Interconnections to inactive objects present
  • A01508BICO: Interconnections to inactive objects exceeded
  • A01514(F) BICO: Error when writing during a reconnect
  • A01590(F) Drive: Motor maintenance interval expired
  • A01691SI Motion: Ti and To unsuitable for DP cycle
  • A01693SI P1 (CU): Safety parameter setting changed, warm restart/POWER ON required
  • A01695SI Motion: Sensor Module was replaced

See all 937 SINAMICS S120 / S150 Drive System fault codes →

Reference manuals (hosted by IAC)

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs Siemens parts — new, refurbished, or exchange units with warranty.

Reference information compiled from official Siemens documentation; always confirm against the manual for your exact unit and firmware.