B&R 3DM476.6
2005 digital mixed module, 16 inputs, 24 VDC / 24 VAC, 1 ms, DC: Sink/Source, 4 electrically isolated input groups, 16 transistor outputs, 24 VDC, 0.4 A
Lifecycle & replacement
Lifecycle status not indexed
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
Short description
| I/O module | 16 digital inputs, 16 digital outputs |
General information
| Diagnostics / Outputs | Yes, using LED status indicator |
| Diagnostics / Operating state of outputs | Yes, using LED status indicator and software |
| Power consumption / Internal / 24 VDC | - |
| Power consumption / Internal / 5 VDC | 2.5 W |
| Power consumption / Internal / Total | 2.5 W |
| Power consumption / External 24 V (DO) | 2.0 W |
| Electrical isolation / Group isolation | Input group - Input group input group - Output group |
| Electrical isolation / Channel - Channel | No |
| Electrical isolation / Channel - PLC | Yes |
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / UL | cULus E115267 Industrial control equipment |
| Status indicators | I/O function per channel, operating state of the outputs |
Digital inputs
| Input filter / Hardware | ≤1 ms |
| Input filter / Software | - |
| Nominal voltage | 24 VDC |
| Input circuit | Sink or source |
Digital outputs
| Nominal voltage | 24 VDC |
| Nominal output current | 0.4 A |
| Total nominal current | 4.8 A |
| Output circuit | Source |
| Output protection | Thermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads, reverse polarity protection of the output power supply |
| Sensor power supply | External |
Operating conditions
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature / Operation | 0 to 60°C |
| Temperature / Storage | -25 to 70°C |
| Relative humidity / Operation | 5 to 95% |
Mechanical properties
| Dimensions / Width | System 2005 single-width |
| Can be installed on / Base unit | Yes |
| Can be installed on / Expansion unit | Yes |
| Note | The connection is made via DSUB connectors and ribbon cable. |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.