IAC

B&R 3IF782.9-1

POWERLINK for real-time Ethernet communication RS485 on multipoint connector aPCI interface module, 1 POWERLINK interface, managing or controlled node, 1 RS485 interface on terminal block, order 1x terminal block TB704 separately!

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
Communication module1x RS485, 1x POWERLINK (V1/V2) managing or controlled node
General information
Diagnostics / Bus function (IF2)Yes, using LED status indicator and software
Diagnostics / Data transfer (IF1)Yes, using LED status indicators
Diagnostics / Station status (IF2)Yes, using LED status indicator and software
Power consumption / 3.3 VDC2.5 W
Power consumption / 5 VDC0.3 W
Power consumption / Total2.8 W
Electrical isolation / IF1 - IF2Yes
Electrical isolation / PLC - IFxYes
Certifications / CEYes
Certifications / UKCAYes
Certifications / ULcULus E115267 Industrial control equipment
Certifications / KCYes
Status indicatorsTransmitting/Receiving data for IF1 Status of POWERLINK station, network activity, link/collision for IF2
Interfaces
Interface IF1 / SignalRS485
Interface IF1 / Variant4-pin male multipoint connector
Interface IF1 / Max. distance1200 m
Interface IF1 / Transfer rateMax. 115.2 kbit/s
Interface IF2 / Transfer / Physical layer100BASE-TX
Interface IF2 / Transfer / Half-duplexYes
Interface IF2 / Transfer / Full-duplexNo
Interface IF2 / Transfer / AutonegotiationYes
Interface IF2 / Transfer / Auto-MDI/MDIXYes
Interface IF2 / FieldbusPOWERLINK (V1/V2) managing or controlled node
Interface IF2 / TypeType 3
Interface IF2 / Variant1x shielded RJ45 port
Interface IF2 / Line lengthMax. 100 m between two stations (segment length)
Interface IF2 / Transfer rate100 Mbit/s
Operating conditions
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation0 to 60°C
Temperature / Storage-25 to 70°C
Relative humidity / Operation5 to 95%, non-condensing
Mechanical properties
NoteOrder 1x terminal block TB704 separately.
SlotSlot, e.g. in the CP360