IAC

B&R 3IF789.9

aPCI interface module, 1 POWERLINK interface, managing or controlled node, 1 X2X Link master interface, electrically isolated, order 1x terminal block TB704 separately!

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
Communication module1x X2X Link master, 1x Ethernet POWERLINK managing or controlled node
General information
LEDs / Quantity6
Diagnostics / Bus function (IF2)Yes, using LED status indicator and software
Diagnostics / Data transfer (IF1)Yes, using LED status indicator and software
Diagnostics / Station status (IF2)Yes, using LED status indicator and software
Power consumption / 3.3 VDC2.3 W
Power consumption / 5 VDC0.5 W
Power consumption / Total2.8 W
Electrical isolation / IF1 - IF2Yes
Electrical isolation / PLC - IFxYes
Certifications / CEYes
Certifications / UKCAYes
Certifications / ULcULus E115267 Industrial control equipment
Certifications / KCYes
LEDsX2X Link Rx/Tx, POWERLINK
B&R ID code0x13E2
Status indicatorsTransmitting/Receiving data for IF1 Status of POWERLINK station, network activity, link/collision for IF2
Interfaces
Interface IF1 / TypeX2X Link master
Interface IF1 / Variant4-pin male multipoint connector
Interface IF1 / Number of stationsMax. 253
Interface IF1 / Internal bus power supplyNo
Interface IF1 / Network topologyLine
Interface IF1 / Distance between 2 stationsMax. 100 m
Interface IF1 / Bus terminating resistorInternal
Interface IF2 / FieldbusEthernet POWERLINK
Interface IF2 / Type100BASE-T (ANSI/IEEE 802.3)
Interface IF2 / VariantShielded RJ45 port
Interface IF2 / Line lengthMax. 100 m between two stations (segment length)
Interface IF2 / Transfer rate100 Mbit/s
Interface IF2 / In/Out buffer20 kB
Operating conditions
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Horizontal mounting orientation0 to 60°C
Temperature / Operation / Vertical mounting orientation0 to 60°C
Temperature / Storage-25 to 70°C
Temperature / Transport-25 to 70°C
Relative humidity / Operation5 to 95%, non-condensing
Relative humidity / Storage5 to 95%, non-condensing
Relative humidity / Transport5 to 95%, non-condensing
Mechanical properties
NoteOrder 1x terminal block TB704 separately.
SlotSlot, e.g. in the CP360

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.