B&R 3IF789.9
aPCI interface module, 1 POWERLINK interface, managing or controlled node, 1 X2X Link master interface, electrically isolated, order 1x terminal block TB704 separately!
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
Short description
| Communication module | 1x X2X Link master, 1x Ethernet POWERLINK managing or controlled node |
General information
| LEDs / Quantity | 6 |
| Diagnostics / Bus function (IF2) | Yes, using LED status indicator and software |
| Diagnostics / Data transfer (IF1) | Yes, using LED status indicator and software |
| Diagnostics / Station status (IF2) | Yes, using LED status indicator and software |
| Power consumption / 3.3 VDC | 2.3 W |
| Power consumption / 5 VDC | 0.5 W |
| Power consumption / Total | 2.8 W |
| Electrical isolation / IF1 - IF2 | Yes |
| Electrical isolation / PLC - IFx | Yes |
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / UL | cULus E115267 Industrial control equipment |
| Certifications / KC | Yes |
| LEDs | X2X Link Rx/Tx, POWERLINK |
| B&R ID code | 0x13E2 |
| Status indicators | Transmitting/Receiving data for IF1 Status of POWERLINK station, network activity, link/collision for IF2 |
Interfaces
| Interface IF1 / Type | X2X Link master |
| Interface IF1 / Variant | 4-pin male multipoint connector |
| Interface IF1 / Number of stations | Max. 253 |
| Interface IF1 / Internal bus power supply | No |
| Interface IF1 / Network topology | Line |
| Interface IF1 / Distance between 2 stations | Max. 100 m |
| Interface IF1 / Bus terminating resistor | Internal |
| Interface IF2 / Fieldbus | Ethernet POWERLINK |
| Interface IF2 / Type | 100BASE-T (ANSI/IEEE 802.3) |
| Interface IF2 / Variant | Shielded RJ45 port |
| Interface IF2 / Line length | Max. 100 m between two stations (segment length) |
| Interface IF2 / Transfer rate | 100 Mbit/s |
| Interface IF2 / In/Out buffer | 20 kB |
Operating conditions
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature / Operation / Horizontal mounting orientation | 0 to 60°C |
| Temperature / Operation / Vertical mounting orientation | 0 to 60°C |
| Temperature / Storage | -25 to 70°C |
| Temperature / Transport | -25 to 70°C |
| Relative humidity / Operation | 5 to 95%, non-condensing |
| Relative humidity / Storage | 5 to 95%, non-condensing |
| Relative humidity / Transport | 5 to 95%, non-condensing |
Mechanical properties
| Note | Order 1x terminal block TB704 separately. |
| Slot | Slot, e.g. in the CP360 |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.