Products B&R 4PP015.0420-36 Power Panel, 24 VDC, 153 x 120 mm, LCD display, 4 x 20 characters, backlight, 16 keys, 300 kB SRAM, 1024 kB FlashPROM, 1 RS232 interface, 1 CAN bus interface network-capable, 8 digital inputs, 24 VDC, sink/source, 2 event counters or 1 incremental encoder or 2x gate/period measurement, 8 digital outputs, 24 VDC, 0.5 A source, 4 analog inputs, ±10 V, 12-bit, 2 of the analog inputs can be used as KTY10 or Pt1000 inputs, 4 analog outputs, ±10 V, 12-bit, IP65 protection (front), order 2x TB718 and 1x TB103 terminal blocks separately!
Lifecycle & replacement Lifecycle status not indexed
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications General information Battery / Type Renata 950 mAh Battery / Variant Lithium ion Diagnostics / I/O function Yes, using LEDs Diagnostics / Interface Yes, using LEDs Diagnostics / State Yes, using LED status indicator Certifications / CE Yes Certifications / UKCA Yes Certifications / CRA (Cyber Resilience Act) Evaluation ongoing Certifications / UL cULus E115267
Industrial control equipment Certifications / CE #2 Yes Status indicators I/O function per channel, status
Controller Real-time clock / Accuracy Resolution 1 s Standard memory / System PROM 448 kB FlashPROM Standard memory / User PROM 1024 kB FlashPROM Standard memory / User RAM 300 kB SRAM Voltage monitoring An NMI is triggered at a supply voltage of <15 VDC. System bus for expansions No Typical instruction cycle time 0.8 µs Watchdog Yes
Display Backlight / Type LED Type Monochrome LCD Resolution 4 x 20 characters Display character set English / Katakana
Interfaces Interface IF1 / Type RS232 Interface IF1 / Variant 9-pin male DSUB connector Interface IF1 / Electrical isolation No Interface IF1 / Max. baud rate 115.2 kbit/s Interface IF2 / Max. transfer rate / Bus length ≤60 m 500 kbit/s Interface IF2 / Max. transfer rate / Bus length ≤200 m 250 kbit/s Interface IF2 / Max. transfer rate / Bus length ≤1000 m 50 kbit/s Interface IF2 / Type CAN Interface IF2 / Variant 9-pin male DSUB connector Interface IF2 / Electrical isolation Yes Interface IF2 / Max. distance 1000 m
Digital inputs Input filter / Channel 1-3 <10 µs Input filter / Channel 4-16 <1 ms Input current at nominal voltage / Channel 1-3 Approx. 10 mA Input current at nominal voltage / Channel 4-16 Approx. 5 mA Electrical isolation / Group isolation No Electrical isolation / Channel - Bus Yes Electrical isolation / Channel - Channel No Additional functions / Channel 1-3 Counters Additional functions / Channel 4-16 - Quantity 8 Nominal voltage 24 VDC Input circuit Sink or source
Analog inputs Electrical isolation / Group isolation No Electrical isolation / Channel - Bus Yes Electrical isolation / Channel - Channel No Input filter / Hardware Cutoff frequency 10 kHz / slope 60 dB Input filter / Software - Quantity 4 differential inputs, 2 of which can be configured individually as temperature inputs Input ±10 V Digital converter resolution 12-bit Conversion time 150 µs for all channels Output format INT Input impedance in signal range 20 MΩ Input circuit IEC 61131-2
Temperature measurement Input filter / Hardware Cutoff frequency 10 kHz / slope 60 dB Input filter / Software - Sensor / Note Configurable per channel Sensor / KTY10-6 -50 to 125°C Sensor / Pt1000 -200 to 850°C Electrical isolation / Group isolation No Electrical isolation / Channel - Bus Yes Electrical isolation / Channel - Channel No Quantity Up to 2 (depends on the configuration) Output format INT Digital converter resolution 12-bit Input Resistance measurement in 2-wire method with constant current supply Input circuit IEC 61131-2 Conversion time 150 µs for all channels Resistance measurement range 0-4000 Ω
Digital outputs Electrical isolation / Group isolation No Electrical isolation / Channel - Bus No Electrical isolation / Channel - Channel No Quantity 8 Nominal voltage 24 VDC Nominal output current 0.5 A Total nominal current 4 A Output circuit Source Output protection Overload protection, short-circuit protection Internal protective circuit VDR
Analog outputs Electrical isolation / Group isolation No Electrical isolation / Channel - Bus Yes Electrical isolation / Channel - Channel No Quantity 4 Output ±10 V Digital converter resolution 12-bit Conversion time 150 µs for all channels Switch on/off behavior Internal enable relay for startup and errors Output protection Single-channel continuous short circuit protection Basic accuracy ±0.088% at 25°
Keys Function keys 10 with LED (yellow) Soft keys 3 System keys Cursor keys
Power supply unit Nominal voltage 24 VDC Power consumption Max. 6 W
Operating conditions Degree of protection per EN 60529 IP65 (front)
Ambient conditions Temperature / Operation 0 to 50°C Temperature / Storage -20 to 60°C Relative humidity / Operation 10 to 90% Relative humidity / Storage 5 to 95%
Mechanical properties Dimensions / Width 153 mm Dimensions / Height 120 mm Dimensions / Depth 46.1 mm Weight 0.5 kg