IAC

B&R 4PPC50.0702-10B

Power Panel C50, 7.0", glass front, controller with mapp View HMI unit. CPU and memory of the controller: 766 MHz (ARM Cortex-A9), 512 MB DRAM, 64 kB FRAM, 2 GB onboard flash drive. CPU and memory of the terminal: 800 MHz (ARM Cortex-A9), 1 GB DRAM. Display and touch screen: 7.0", 800 x 480 (WVGA) resolution, projected capacitive touch screen, multi-touch support, glass front with black frame, landscape and portrait format configurable with software. Interfaces: 1x POWERLINK, 1x Ethernet 10/100 Mbit/s, 1x X2X Link, 2x USB 2.0.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

General information
System requirements / Automation Studio4.7.1
System requirements / Automation Runtime4.71
Support / mapp ViewYes
Support / Controller redundancyNo
Support / ACOPOS supportYes
Support / Visual Components supportYes
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / ULcULus E115267 Industrial control equipment
B&R ID code0xF5DD
CoolingPassive
Power buttonNo
Reset buttonYes
Status indicatorsOperating state, license violation, overtemperature shutdown, interface status
BuzzerYes
Controller
Processor / L1 cache / Data code32 kB
Processor / L1 cache / Program code32 kB
Processor / TypeARM Cortex-A9
Processor / Clock frequency2x 766 MHz
Processor / L2 cache512 kB
Application memory / Writable data amount / Guaranteed40 TB
Application memory / Writable data amount / Results for 5 years21.9 GB/day
Application memory / Type2 GB eMMC flash memory
Application memory / Data retention10 years
Application memory / Guaranteed erase/write cycles20,000
Application memory / Error-correcting code (ECC)Yes
Application memory / Storage health data supportYes, AR 4.90 and later
Real-time clockNonvolatile, resolution 1 s, -25 to 37 ppm accuracy at 25°C
Floating point unit (FPU)Yes
Mode/Node switchesNo
Remanent variables64 kB FRAM, retention >10 years
DRAM512 MB
Shortest task class cycle time0.4 ms
Typical instruction cycle time0.01 µs
Temperature cutoffYes
Terminal
Processor / L1 cache / Data code32 kB
Processor / L1 cache / Program code32 kB
Processor / TypeARM Cortex-A9
Processor / Clock frequency2x 800 MHz
Processor / L2 cache512 kB
Application memory / Writable data amount / Guaranteed40 TB
Application memory / Writable data amount / Results for 5 years21.9 GB/day
Application memory / Type2 GB eMMC flash memory
Application memory / Data retention10 years
Application memory / Guaranteed erase/write cycles20,000
Application memory / Error-correcting code (ECC)Yes
DRAM1 GB
Display
Viewing angles / HorizontalDirection L / Direction R = Typ. 70°
Viewing angles / VerticalRev. ≥ H3: Direction U / Direction D = Typ. 50° Rev. < H3: Direction U / Direction D = Typ. 60°
Backlight / TypeLED
Backlight / BrightnessTyp. 500 cd/m²
Backlight / Half-brightness time50,000 h
Touch screen / TypeMulti-touch
Touch screen / TechnologyPCT (projected capacitive touch)
Touch screen / SurfaceGlass, chemically hardened (6H)
TypeTFT color
Diagonal7.0"
Colors16.7 million (RGB, 8 bits per channel)
ResolutionWVGA, 800 x 480 pixels
ContrastRev. ≥ H3: Typ. 550:1 Rev. < H3: Typ. 600:1
Screen rotationYes
Interfaces
Interface IF1 / Transfer / Physical layer100BASE-TX
Interface IF1 / Transfer / Half-duplexYes
Interface IF1 / Transfer / Full-duplexPOWERLINK mode: No / Ethernet mode: Yes
Interface IF1 / Transfer / AutonegotiationYes
Interface IF1 / Transfer / Auto-MDI/MDIXYes
Interface IF1 / FieldbusPOWERLINK V2 managing or controlled node
Interface IF1 / TypeType 6
Interface IF1 / Variant1x RJ45 shielded
Interface IF1 / Line lengthMax. 100 m between 2 nodes (segment length)
Interface IF1 / Max. transfer rate100 Mbit/s
Interface IF2 / Transfer / Physical layer10BASE-T/100BASE-TX/1000BASE-T
Interface IF2 / Transfer / Half-duplexYes
Interface IF2 / Transfer / Full-duplexYes
Interface IF2 / Transfer / AutonegotiationYes
Interface IF2 / Transfer / Auto-MDI/MDIXYes
Interface IF2 / TypeEthernet
Interface IF2 / Variant1x RJ45 shielded
Interface IF2 / Line lengthMax. 100 m between 2 nodes (segment length)
Interface IF2 / Max. transfer rate10/100/1000 Mbit/s
Interface IF3 / TypeUSB 2.0
Interface IF3 / VariantType A
Interface IF3 / Current-carrying capacity0.5 A
Interface IF4 / TypeUSB 2.0
Interface IF4 / VariantType A
Interface IF4 / Current-carrying capacity0.5 A
Interface IF5 / FieldbusX2X Link master
Interface IF5 / Line lengthMax. 100 m between 2 nodes (segment length)
Electrical properties
Nominal voltage24 VDC -25% / +30%, PELV
Power consumptionMax. 21 W
Fuse3 A slow-blow, internal
Reverse polarity protectionYes
Electrical isolationPOWERLINK (IF1), Ethernet (IF2) and X2X Link (IF5) isolated from each other, from other interfaces and from the base device
Operating conditions
Permissible mounting orientations / Standard mounting orientationVertical
Permissible mounting orientations / Inclination±25°
Permissible mounting orientations / RotationIn 90° increments (portrait/landscape)
Installation elevation above sea level / 0 to 2000 mNo limitation
Installation elevation above sea level / >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529Front: IP55, Back: IP20
Ambient conditions
Temperature / Operation-20 to 60°C
Temperature / Storage-20 to 80°C
Temperature / Transport-20 to 80°C
Relative humiditySee temperature/humidity diagram.
Mechanical properties
Front / DesignBlack
Dimensions / Width197 mm
Dimensions / Height140 mm
Dimensions / Depth42.2 mm
Weight1.13 kg

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.