B&R 4PPC70.0573-21W
Power Panel C70, 5.7", landscape format, fieldbus interfaces: 2x CAN bus. CPU and memory: Intel Atom 333 MHz (compatible), 256 MB DDRAM, 32 kB FRAM, 2 GB onboard flash drive. Display and touch screen: 5.7", 640 x 480 (VGA) resolution, analog resistive touch screen, landscape format, aluminum white pinstripe. Interfaces: 1x POWERLINK, 1x Ethernet 10/100 Mbit/s, 1x X2X Link, 2x USB 2.0, 2x CAN bus.
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
General information
| System requirements / Automation Studio | 4.1.4.375 and later |
| System requirements / Automation Runtime | K4.08 and later |
| System requirements / Support for X20SLX modules | Rev. B4 and later |
| Support / Controller redundancy | No |
| Support / ACOPOS support | Yes |
| Support / Visual Components support | Yes |
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | Non-compliant |
| Certifications / UL | cULus E115267 Industrial control equipment |
| B&R ID code | 0xE55E |
| Cooling | Fanless |
| Power button | No |
| Reset button | Yes |
| Status indicators | Supply voltage OK, operating state, module status, POWERLINK, Ethernet, CAN Rx/Tx |
| Buzzer | Yes |
Controller
| Processor / L1 cache / Data code | 24 kB |
| Processor / L1 cache / Program code | 32 kB |
| Processor / Type | Atom E620T |
| Processor / Clock frequency | 333 MHz (compatible) |
| Processor / L2 cache | 512 kB |
| Application memory / Writable data amount / Guaranteed | 40 TB |
| Application memory / Writable data amount / Results for 5 years | 21.9 GB/day |
| Application memory / Type | 2 GB eMMC flash memory |
| Application memory / Data retention | 10 years |
| Application memory / Guaranteed erase/write cycles | 20,000 |
| Application memory / Error-correcting code (ECC) | Yes |
| Application memory / Storage health data support | Yes, starting with AR 4.90 and hardware revision F0 |
| Bootloader | Automation Runtime AR 4.08 |
| Real-time clock | Nonvolatile, resolution 1 s, -10 to 10 ppm accuracy at 25°C |
| Floating point unit (FPU) | Yes |
| Mode/Node switches | No |
| Remanent variables | 32 kB FRAM, retention >10 years |
| DRAM | 256 MB |
| Shortest task class cycle time | 0.4 ms |
| Typical instruction cycle time | 0.01 µs |
| Temperature cutoff | Yes, at >88°C |
Display
| Viewing angles / Horizontal | Direction L / Direction R = Typ. 80° |
| Viewing angles / Vertical | Direction U / Direction D = Typ. 70° |
| Backlight / Type | LED |
| Backlight / Brightness | Typ. 400 cd/m² |
| Backlight / Half-brightness time | 50,000 h |
| Touch screen / Type | AMT |
| Touch screen / Technology | Analog resistive |
| Touch screen / Controller | B&R, serial, 12-bit |
| Touch screen / Transmittance | 80% ±3% |
| Type | TFT color |
| Diagonal | 5.7" |
| Colors | 262,144 (RGB, 6 bits per channel) |
| Resolution | VGA, 640 x 480 pixels |
| Contrast | Typ. 850:1 |
| Screen rotation | Yes, using Visual Components |
Interfaces
| Interface IF1 / Transfer / Physical layer | 100BASE-TX |
| Interface IF1 / Transfer / Half-duplex | Yes |
| Interface IF1 / Transfer / Full-duplex | POWERLINK mode: No / Ethernet mode: Yes |
| Interface IF1 / Transfer / Autonegotiation | Yes |
| Interface IF1 / Transfer / Auto-MDI/MDIX | Yes |
| Interface IF1 / Fieldbus | POWERLINK V2 managing or controlled node |
| Interface IF1 / Type | Type 4 |
| Interface IF1 / Variant | 1x RJ45 shielded |
| Interface IF1 / Line length | Max. 100 m between 2 nodes (segment length) |
| Interface IF1 / Max. transfer rate | 100 Mbit/s |
| Interface IF2 / Transfer / Physical layer | 10BASE-T/100BASE-TX |
| Interface IF2 / Transfer / Half-duplex | Yes |
| Interface IF2 / Transfer / Full-duplex | Yes |
| Interface IF2 / Transfer / Autonegotiation | Yes |
| Interface IF2 / Transfer / Auto-MDI/MDIX | Yes |
| Interface IF2 / Type | Ethernet |
| Interface IF2 / Variant | 1x RJ45 shielded |
| Interface IF2 / Line length | Max. 100 m between 2 nodes (segment length) |
| Interface IF2 / Max. transfer rate | 10/100 Mbit/s |
| Interface IF3 / Type | USB 2.0 |
| Interface IF3 / Variant | Type A |
| Interface IF3 / Current-carrying capacity | 0.49 A |
| Interface IF4 / Type | USB 2.0 |
| Interface IF4 / Variant | Type A |
| Interface IF4 / Current-carrying capacity | ≥Rev. E0: 0.20 A <Rev. E0: 0.10 A |
| Interface IF5 / Fieldbus | X2X Link master |
| Interface IF6 / Max. transfer rate / Bus length ≤25 m | 1 Mbit/s |
| Interface IF6 / Max. transfer rate / Bus length ≤60 m | 500 kbit/s |
| Interface IF6 / Max. transfer rate / Bus length ≤200 m | 250 kbit/s |
| Interface IF6 / Max. transfer rate / Bus length ≤1000 m | 50 kbit/s |
| Interface IF6 / Type | CAN bus |
| Interface IF6 / Variant | 3 pins of the 6-pin multipoint connector |
| Interface IF6 / Max. distance | 1000 m |
| Interface IF6 / Terminating resistor | Hardware revisions ≥G0: Integrated, can be switched on using software Hardware revision <G0: Must be wired externally |
| Interface IF7 / Max. transfer rate / Bus length ≤25 m | 1 Mbit/s |
| Interface IF7 / Max. transfer rate / Bus length ≤60 m | 500 kbit/s |
| Interface IF7 / Max. transfer rate / Bus length ≤200 m | 250 kbit/s |
| Interface IF7 / Max. transfer rate / Bus length ≤1000 m | 50 kbit/s |
| Interface IF7 / Type | CAN bus |
| Interface IF7 / Variant | 3 pins of the 6-pin multipoint connector |
| Interface IF7 / Max. distance | 1000 m |
| Interface IF7 / Terminating resistor | Hardware revisions ≥G0: Integrated, can be switched on using software Hardware revisions <G0: Must be wired externally |
Electrical properties
| Nominal voltage | 24 VDC -15% / +20% |
| Max. power consumption | 14.4 W |
| Reverse polarity protection | Yes |
| Electrical isolation | IF1, IF2 and IF5 isolated from each other, from other interfaces and from the base device |
Operating conditions
| Permissible mounting orientations / Standard mounting orientation | Vertical |
| Permissible mounting orientations / Inclination | ±25° |
| Permissible mounting orientations / Rotation | In 90° increments (portrait/landscape) |
| Installation elevation above sea level / 0 to 2000 m | No limitation |
| Installation elevation above sea level / >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | Front: IP65, Back: IP20 |
| Degree of protection per UL 50 | Front: Type 4X indoor use only |
Ambient conditions
| Temperature / Operation | 0 to 50°C |
| Temperature / Storage | -20 to 70°C |
| Temperature / Transport | -20 to 70°C |
| Relative humidity | See temperature/humidity diagram. |
Mechanical properties
| Front / Design | Aluminum white pinstripe |
| Dimensions / Width | 172 mm |
| Dimensions / Height | 140 mm |
| Dimensions / Depth | 51 mm |
| Weight | 0.6 kg |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Manuals
3D CAD models
ECAD / EPLAN
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.