IAC

B&R 5ACCIF01.FPCC-000

1x POWERLINK interface managing or controlled node 2x CAN bus master interfaces 1x X2X Link master interface 512 kB nvSRAM Compatible with APC2x00 / PPC2x00 Interface option 5ACCIF01.FPCC-000 is equipped with a POWERLINK interface, 2 CAN bus master interfaces and an X2X Link master interface. In addition, 512 kB nvSRAM is installed.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

General information
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / ULcULus E115267 Industrial control equipment
Certifications / HazLoccULus HazLoc E180196 Industrial control equipment for hazardous locations Class I, Division 2, Groups ABCD, T4
Certifications / DNVTemperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: A (0.7 g) EMC: B (bridge and open deck)
Certifications / CCSYes
Certifications / LRENV3
Certifications / KRYes
Certifications / ABSYes
Certifications / BVEC31B Temperature: 5 - 55°C Vibration: 0.7 g EMC: Bridge and open deck
LEDsL1, L2, L3
B&R ID code0xE9BD
Controller
nvSRAM / Size512 kB
nvSRAM / Data retention20 years
nvSRAM / Read/Write enduranceMin. 1,000,000
nvSRAM / Remanent variables in power failure mode256 kB (for e.g. Automation Runtime, see Automation Help)
Interfaces
POWERLINK / Quantity1
POWERLINK / TypeType 4
POWERLINK / ExecutionRJ45, shielded
POWERLINK / Transfer rate100 Mbit/s
POWERLINK / Transfer100BASE-TX
POWERLINK / Line lengthMax. 100 m between two stations (segment length)
CAN / Terminating resistor / TypeCan be switched on and off with slide switch
CAN / Terminating resistor / Default settingEach off
CAN / Quantity2
CAN / Execution10-pin, male
CAN / Transfer rateMax. 1 Mbit/s
X2X / TypeX2X Link master
X2X / Quantity1
X2X / Execution10-pin, male, galvanically isolated
Electrical properties
Power consumption2 W
Operating conditions
Pollution degree per EN 61131-2Pollution degree 2
Ambient conditions
Temperature / Operation-20 to 55°C
Temperature / Storage-20 to 60°C
Temperature / Transport-20 to 60°C
Relative humidity / Operation5 to 90%, non-condensing
Relative humidity / Storage5 to 95%, non-condensing
Relative humidity / Transport5 to 95%, non-condensing
Mechanical properties
Weight25 g

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.