The SDL4 Converter makes operation via SDL4 with Automation Panels possible for B&R industrial PCs that are not equipped with an SDL4 interface or SDL4 slot. This makes it easy to upgrade systems to SDL4 as part of retrofit measures and conversions. When combined with an SDL4 interface integrated on a B&R industrial PC, two Automation Panels can be connected in dual-independent display mode.
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
General information
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | In preparation |
| Certifications / UL | cULus E115267 Industrial control equipment |
| LEDs | Status, SDL4 Out |
| B&R ID code | 0xF10C |
Interfaces
| USB / Quantity | 1 |
| USB / Type | USB 2.0 |
| USB / Variant | Type B |
| USB / Transfer rate | Low speed (1.5 Mbit/s), full speed (12 Mbit/s) to high speed (480 Mbit/s) |
| SDL/DVI-D interface / Variant | DVI-I |
| SDL/DVI-D interface / Type | SDL/DVI |
| SDL4 Out / Quantity | 1 |
| SDL4 Out / Variant | Female RJ45 connector, shielded |
| SDL4 Out / Type | SDL4 |
Electrical properties
| Nominal voltage | 24 VDC ±25%, SELV |
| Nominal current | Max. 0.3 A |
| Overvoltage category per EN 61131-2 | II |
| Galvanic isolation | Yes |
Operating conditions
| Pollution degree per EN 61131-2 | Pollution degree 2 |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature / Operation | 0 to 55°C |
| Temperature / Storage | -20 to 60°C |
| Temperature / Transport | -20 to 60°C |
| Relative humidity / Operation | 5 to 90%, non-condensing |
| Relative humidity / Storage | 5 to 95%, non-condensing |
| Relative humidity / Transport | 5 to 95%, non-condensing |
| Vibration / Operation (continuous) | 2 to 9 Hz: 1.75 mm amplitude / 9 to 200 Hz: 0.5 g peak |
| Vibration / Operation (occasional) | 2 to 9 Hz: 3.5 mm amplitude / 9 to 200 Hz: 1 g peak |
| Vibration / Storage | 2 to 8 Hz: 7.5 mm amplitude / 8 to 200 Hz: 2 g peak / 200 to 500 Hz: 4 g peak |
| Vibration / Transport | 2 to 8 Hz: 7.5 mm amplitude / 8 to 200 Hz: 2 g peak / 200 to 500 Hz: 4 g peak |
| Shock / Operation | 15 g peak, 11 ms |
| Shock / Storage | 30 g peak, 6 ms |
| Shock / Transport | 30 g peak, 6 ms |
| Elevation / Operation | Max. 3000 m |
Mechanical properties
| Housing / Material | Aluminum |
| Housing / Coating | White |
| Dimensions / Width | 40 mm |
| Dimensions / Height | 100 mm |
| Dimensions / Depth | 80 mm |
| Weight | Approx. 400 g |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Manuals
3D CAD models
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.