B&R 5LS182.8
POWERLINK V2 for real-time Ethernet communication Integrated hub for economical wiring Configurable ring redundancy Poll response chaining Logic scanner, PCIe half-size module, 1 POWERLINK interface, managing or controlled node, integrated 2-port hub, ring redundancy function, PRC function, 1 MB SRAM (Automation Runtime)
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
Short description
| Communication module | 1x POWERLINK V2 managing or controlled node |
General information
| System requirements / Automation Runtime | Starting with 4.45 and 4.51 |
| Diagnostics / Bus function | Yes, using LED status indicator and software |
| Diagnostics / Station status | Yes, using LED status indicator and software |
| Electrical isolation / PC - IFx | Yes |
| Certifications / CE | Yes |
| Certifications / CRA (Cyber Resilience Act) | In preparation |
| Certifications / UL | cULus E115267 Industrial control equipment |
| B&R ID code | 0xEAFC |
| Status indicators | Status of the POWERLINK station, network activity, link |
| Power consumption | 1.7 W |
Controller
| SRAM | 1 MB |
Interfaces
| Transfer / Physical layer | ANSI/IEEE 802.3 |
| Transfer / Half-duplex | Yes |
| Transfer / Full-duplex | No |
| Transfer / Autonegotiation | Yes |
| Transfer / Auto-MDI/MDIX | Yes |
| Fieldbus | POWERLINK V2 managing or controlled node |
| Type | Type 4 |
| Execution | 2x shielded RJ45 (hub) |
| Line length | Max. 100 m between 2 stations (segment length) |
| Transfer rate | 100 Mbit/s |
| Hub propagation delay | <1 µs |
Operating conditions
| Degree of protection per EN 60529 | IP20 in installed state |
Ambient conditions
| Temperature / Operation | 0 to 55°C |
| Temperature / Storage | -40 to 85°C |
| Temperature / Transport | -40 to 85°C |
| Relative humidity / Operation | 0 to 95%, non-condensing |
| Relative humidity / Storage | 0 to 95%, non-condensing |
| Relative humidity / Transport | 0 to 95%, non-condensing |
Mechanical properties
| Installation in / B&R Automation PC | Yes |
| Slot | Standard PCIe half-size module, Plug and Play |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
3D CAD models
ECAD / EPLAN
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.