B&R 5LS189.6
Logic scanner POWERLINK, PCI half-size module, 1 POWERLINK interface, managing or controlled node, 1 X2X Link master interface, electrically isolated, 1 MB SRAM (Automation Runtime), order 2x terminal blocks TB704 separately!
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
Short description
| Communication module | 1x X2X Link master, 1x Ethernet POWERLINK managing or controlled node |
General information
| Diagnostics / Bus function (IF2) | Yes, using LED status indicator and software |
| Diagnostics / Data transfer (IF1) | Yes, using software |
| Diagnostics / Station status (IF2) | Yes, using LED status indicator and software |
| Electrical isolation / IF1 - IF2 | Yes |
| Electrical isolation / PC - IFx | Yes |
| Certifications / CE | Yes |
| Certifications / UL | cULus E115267 Industrial control equipment |
| Ready relay | Normally open and normally closed contact, max. 30 VDC, max. 10 A |
| Status indicators | Status of the POWERLINK station, network activity, link/collision for IF2 |
| Power consumption | 4.0 W |
Controller
| SRAM | 1 MB, battery-backed |
Interfaces
| Interface IF1 / Type | X2X Link master |
| Interface IF1 / Variant | 4-pin male multipoint connector |
| Interface IF2 / Fieldbus | Ethernet POWERLINK |
| Interface IF2 / Type | 100BASE-T (ANSI/IEEE 802.3) |
| Interface IF2 / Variant | Shielded RJ45 port |
| Interface IF2 / Line length | Max. 100 m between two stations (segment length) |
| Interface IF2 / Transfer rate | 100 Mbit/s |
Operating conditions
| Degree of protection per EN 60529 | IP20 in installed state |
Ambient conditions
| Temperature / Operation | 0 to 55°C |
| Temperature / Storage | -25 to 70°C |
| Relative humidity / Operation | 0 to 95% |
Mechanical properties
| Installation in / B&R Automation PC APC6xx | Yes |
| Installation in / B&R Panel PC | Yes |
| Installation in / Desktop PC | Yes |
| Note | Order 2x TB704 terminal blocks separately Lithium battery included in delivery |
| Slot | Standard PCI half-size module, Plug & Play |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
ECAD / EPLAN
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.