Siemens 6SL3220-2YD36-0UB0

SINAMICS G120X Power Converter

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for Siemens part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Official description

SINAMICS G120XA Rated power 37kW 3AC 380V -20% to 440V +10% unfiltered 110% 60s per 600s with integrated BOP-2 Integrated Fieldbus: MODBUS RTU, BACnet MS/TP, USS 6DI, 4DQ, 2AI, 2AQ, 1Mot_t Protection: IP20 Frame Size: FSD 472x200x239 (HxWxD)

Source: Siemens catalog short-text.

Specifications

designationSINAMICS G120XA infrastructure converter 37 kW, 380-440 V, FSD (template: dots = operator panel 1/2/3, comm B/F; without line filter)
ratedPowerKw37
ratedOutputCurrentA68
maxOutputCurrentA75
frameSizeFSD
inputVoltage380-440 V 3 AC
environmentalClass3C2
seriesG120XA
degreeOfProtectionIP20
filterClassnone

Source: Siemens catalog (family ordering-data row).

Fault codes for this drive converter (603)

  • A01006Firmware update for DRIVE-CLiQ component required
  • A01007POWER ON for DRIVE-CLiQ component required
  • A01009CU: Control module overtemperature
  • A01016Firmware changed
  • A01017Component lists changed
  • A01019Writing to the removable data medium unsuccessful
  • A01020Writing to RAM disk unsuccessful
  • A01021Removable data medium as USB data storage medium from the PC used
  • A01028Configuration error
  • A01035ACX: Parameter back-up file corrupted
  • A01045Configuring data invalid
  • A01049It is not possible to write to file
  • A01064(F) CU: Internal error (CRC)
  • A01066Buffer memory: 70% fill level reached or exceeded
  • A01067Buffer memory: 100 % fill level reached
  • A01069Parameter backup and device incompatible
  • A01073(N) POWER ON required for backup copy on memory card
  • A01251CU: CU-EEPROM incorrect read-write data
  • A01304(F) Firmware version of DRIVE-CLiQ component is not up-to-date
  • A01306Firmware of the DRIVE-CLiQ component being updated
  • A01314Topology: Component must not be present
  • A01315Drive object not ready for operation
  • A01316Drive object inactive and again ready for operation
  • A01317(N) Deactivated component again present
  • A01318BICO: Deactivated interconnections present
  • A01319Inserted component not initialized
  • A01321Topology: Drive object number does not exist in configuration
  • A01322Topology: Drive object number present twice in configuration
  • A01323Topology: More than two partial lists created
  • A01324Topology: Dummy drive object number incorrectly created
  • A01382Topology: Sensor Module incorrectly inserted
  • A01383Topology: Terminal Module incorrectly inserted
  • A01384Topology: DRIVE-CLiQ Hub Module incorrectly inserted
  • A01385Topology: Controller Extension incorrectly inserted
  • A01386Topology: DRIVE-CLiQ component incorrectly inserted
  • A01389Topology: Motor with DRIVE-CLiQ incorrectly inserted
  • A01416Topology: Component additionally inserted
  • A01420DRIVE-CLiQ component different
  • A01425Topology: Serial number different
  • A01428Topology: Incorrect connection used
  • A01481(N) Topology: power unit not inserted
  • A01482DRIVE-CLiQ component Sensor Module missing
  • A01483Topology: Terminal Module not inserted
  • A01484Topology: DRIVE-CLiQ Hub Module not inserted
  • A01485Topology: Controller Extension not inserted
  • A01486Topology: DRIVE-CLiQ component not inserted
  • A01487Topology: Option slot component not inserted
  • A01489Topology: Motor with DRIVE-CLiQ not inserted
  • A01507(F, N) BICO: Interconnections to inactive objects present
  • A01508BICO: Interconnections to inactive objects exceeded
  • A01514(F) BICO: Error when writing during a reconnect
  • A01590(F) Drive: Motor maintenance interval expired
  • A01654SI P1 (CU): Deviating PROFIsafe configuration
  • A01666SI Motion P1 (CU): Steady-state (static) 1 signal at the F-DI for safe acknowledgment
  • A01669SI Motion: Unfavorable combination of motor and power unit
  • A01678SI: Test stop for STO via terminals required at the PM
  • A01693SI P1 (CU): Safety parameter setting changed, POWER ON required
  • A01696SI Motion: Test stop for the motion monitoring functions selected when booting
  • A01697SI Motion: Test stop for motion monitoring functions required
  • A01698SI P1 (CU): Commissioning mode active

See all 603 SINAMICS G120 Converter (CU250S-2) fault codes →