IAC

Siemens 6SL3320-1TG35-8AA0

SINAMICS S120 Single Motor Module (Chassis, Air-Cooled)

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for Siemens part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

Replacing or upgrading a servo component?

Servo amplifiers, motors, encoders and cables are matched sets. If this part is no longer available in its original form, the manufacturer's newer generation usually will not pair with the rest of the axis, so an upgrade normally covers the drive, motor and cables together. Send us the nameplate details and we will confirm availability of an exact spare or scope a compatible upgrade.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Official description

SINAMICS S120 Single Motor Module input: 675-1035 V DC output: 0-690 V 3AC, 575 A type rating: 560 kW built-in unit IP00 internal air cooling incl. DRIVE-CLiQ cable

Source: Siemens catalog short-text.

Fault codes for this power module (937)

  • A01006Firmware update for DRIVE-CLiQ component required
  • A01007POWER ON for DRIVE-CLiQ component required
  • A01009CU: Control module overtemperature
  • A01013CU: Fan operating time reached or exceeded
  • A01016Firmware changed
  • A01017Component lists changed
  • A01020Writing to RAM disk unsuccessful
  • A01032ACX: all parameters must be saved
  • A01035ACX: Parameter back-up file corrupted
  • A01045CU: Configuring data invalid
  • A01049CU: It is not possible to write to file
  • A01064CU: Internal error (CRC)
  • A01069Parameter backup and device incompatible
  • A01073POWER ON required for backup copy on memory card
  • A01097NTP server cannot be accessed
  • A01099UTC synchronization tolerance violated
  • A01100CU: Memory card withdrawn
  • A01223CU: Sampling time inconsistent
  • A01224CU: Pulse frequency inconsistent
  • A01251CU: CU-EEPROM incorrect read-write data
  • A01256CU: Option Board EEPROM read-write data error
  • A01276Hardware description not fully compatible
  • A01302Error in the component trace
  • A01304(F) Firmware version of DRIVE-CLiQ component is not up-to-date
  • A01306Firmware of the DRIVE-CLiQ component being updated
  • A01314Topology: Component must not be present
  • A01317(N) Deactivated component again present
  • A01318BICO: Deactivated interconnections present
  • A01319Inserted component not initialized
  • A01320Topology: Drive object number does not exist in configuration
  • A01321Topology: Drive object number does not exist in configuration
  • A01322Topology: Drive object number present twice in configuration
  • A01323Topology: More than two partial lists created
  • A01324Topology: Dummy drive object number incorrectly created
  • A01381Topology: power unit incorrectly inserted
  • A01382Topology: Sensor Module incorrectly inserted
  • A01383Topology: Terminal Module incorrectly inserted
  • A01384Topology: DRIVE-CLiQ Hub Module incorrectly inserted
  • A01385Topology: Controller Extension incorrectly inserted
  • A01386Topology: DRIVE-CLiQ component incorrectly inserted
  • A01389Topology: Motor with DRIVE-CLiQ incorrectly inserted
  • A01416Topology: Component additionally inserted
  • A01420Topology: Component different
  • A01425Topology: Serial number different
  • A01428Topology: Incorrect connection used
  • A01481Topology: Motor Module not connected
  • A01482Topology: Sensor Module not connected
  • A01483Topology: Terminal Module not connected
  • A01484Topology: DRIVE-CLiQ Hub Module not connected
  • A01485Topology: Controller Extension not connected
  • A01486Topology: DRIVE-CLiQ component not connected
  • A01487Topology: Option slot component not inserted
  • A01489Topology: motor with DRIVE-CLiQ not connected
  • A01507BICO: Interconnections to inactive objects present
  • A01508BICO: Interconnections to inactive objects exceeded
  • A01514(F) BICO: Error when writing during a reconnect
  • A01590(F) Drive: Motor maintenance interval expired
  • A01691SI Motion: Ti and To unsuitable for DP cycle
  • A01693SI P1 (CU): Safety parameter setting changed, warm restart/POWER ON required
  • A01695SI Motion: Sensor Module was replaced

See all 937 SINAMICS S120 / S150 Drive System fault codes →

Reference manuals (hosted by IAC)

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs Siemens parts — new, refurbished, or exchange units with warranty.

Reference information compiled from official Siemens documentation; always confirm against the manual for your exact unit and firmware.