B&R 7XV116.50-51
Remote valve terminal connection, 16 digital outputs, 0.1 A, 24 VDC, for 25-pin DSUB multipin connector, GND pin 22, 23, 24, 25, X2X Link, electrically isolated, IP67 protection
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
General information
| Diagnostics / Power supply | 24 VDC OUT: Yes, using LED and software 24 VDC X2X: Yes, using software |
| Diagnostics / X2X Link | Yes, using software |
| Diagnostics / Overload | Yes, using LED and software (outputs) |
| Power consumption / Internal I/O | Max. 1.5 W (without load) |
| Power consumption / X2X Link power supply | Max. 0.75 W |
| Electrical isolation / Digital outputs - 24 VDC X2X, OUT power supply | No |
| Electrical isolation / X2X Link - 24 VDC X2X, OUT power supply | Yes |
| Electrical isolation / X2X Link - Digital outputs | Yes |
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | In preparation |
| Certifications / ATEX | Zone 2, II 3G Ex nA IIA T5 Gc IP67, Ta = 0 - Max. 60°C TÜV 05 ATEX 7201X |
| Certifications / UL | cULus E115267 Industrial control equipment |
| B&R ID code | 0x1CEC |
| Status LED | Yes (color / blink code) 24 VDC OUT power supply (DCOK LED) = Yes (color / blink code) |
| Status indicators | Operating status and power supply |
| Remote valve terminal connection for 25-pin DSUB multi-pin connection | 16 valves |
Circuit
| Bus connection | M12 |
| GND pin | 22, 23, 24, 25 |
| Power supply | M8 |
Interfaces
| User interface / Execution | M12 |
| User interface / Type | X2X Link slave |
Digital outputs
| Switching delay / 0 → 1 | Typ. 100 μs / max. 150 μs |
| Switching delay / 1 → 0 | Typ. 125 μs / max. 200 μs |
| Switching voltage | 24 VDC ±25% |
| Total nominal current | 1.6 A |
| Output circuit | Source |
| Output protection | Protected against short circuit, overload and overtemperature |
| Type | High-side driver (source) |
| Max. output current | 0.1 A |
| Max. switching frequency | 100 Hz |
Operating conditions
| Mounting orientation / Horizontal | Yes |
| Mounting orientation / Vertical | Yes |
| Degree of protection per EN 60529 | IP67 |
Ambient conditions
| Temperature / Operation | 0 to 55°C |
| Temperature / Storage | -20 to 70°C |
| Temperature / Transport | -20 to 70°C |
| Relative humidity / Operation | 5 to 95%, non-condensing |
| Relative humidity / Storage | 5 to 95%, non-condensing |
| Relative humidity / Transport | 5 to 95%, non-condensing |
Mechanical properties
| Note | Order male/female M12/M8 connectors separately |
| Installation | 25-pin DSUB, screw mounting, 4-40 UNC |
| Weight | 125 g |
| Module dimensions including mounting plates | 62 x 70 x 30 mm (H x W x D) |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Manuals
3D CAD models
Certificates
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.