Servo amplifiers, motors, encoders and cables are matched sets. If this part is no longer available in its original form, the manufacturer's newer generation usually will not pair with the rest of the axis, so an upgrade normally covers the drive, motor and cables together. Send us the nameplate details and we will confirm availability of an exact spare or scope a compatible upgrade.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

General information
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / ULcULus E225616 Power conversion equipment
Certifications / KCYes
Cooling and mounting typeCold plate or pass-through mounting
DC bus connection
Voltage / Nominal750 VDC
Voltage / Workspace350 to 800 VDC
Continuous power consumptionMax. 880 W
Power dissipation with continuous power25 W (0% continuous power) 36 W (50% continuous power) 70 W (100% continuous power)
DC bus capacitance220 nF
VariantACOPOSmulti backplane
24 VDC internal system power supply
VariantACOPOSmulti backplane
42 VDC output
Output voltage / DC bus voltage (UDC): 260 to 315 VDC0 V
Output voltage / DC bus voltage (UDC): 315 to 800 VDC42 VDC
Reduction of continuous power depending on installation elevation / Starting at 500 m above sea level80 W per 1000 m
Continuous power800 W
Continuous current16 ADC
Reduction of continuous power at ambient temperatures starting at 40°CNo reduction
Reduction of continuous power depending on cooling methodNo reduction
Startup delayMax. 1 s
Startup timeApprox. 5 to 20 ms
Residual rippleTyp. 50 mVSS
42 VDC Out
Output voltage / DC bus voltage (UDC): 260 to 315 VDC0 V
Output voltage / DC bus voltage (UDC): 315 to 800 VDC42 VDC ±6%
Protective measures / No-load proofYes
Protective measures / Overload-proofYes
Protective measures / Short-circuit proofYes
Protective measures / Feedback protection42 VDC Out1: Max. 50 VDC (also when the power is switched off) 42 VDC Out2: Max. 50 VDC (also when the power is switched off)
Protective measures / Overtemperature protectionYes
Protective measures / Dielectric strength to ground±96 VDC
Protective measures / Output/Input isolationSELV / PELV requirements
Variant / 42 VDC, COMConnector
Terminal connection cross section of 42 VDC Out 1 output / Flexible and fine-stranded wires / With wire end sleeve0.25 to 6 mm²
Terminal connection cross section of 42 VDC Out 1 output / Approbation data / UL/C-UL-US22 to 10 AWG
Terminal connection cross section of 42 VDC Out 1 output / Approbation data / CSA22 to 10 AWG
Terminal connection cross section of 42 VDC Out 2 output / Flexible and fine-stranded wires / With wire end sleeve0.25 to 2.5 mm²
Terminal connection cross section of 42 VDC Out 2 output / Approbation data / UL/C-UL-US22 to 12 AWG
Terminal connection cross section of 42 VDC Out 2 output / Approbation data / CSA22 to 12 AWG
Peak current (<4 s) over total DC bus voltage operating range21 ADC
Protection of 42 VDC Out 1 output16 A (slow-blow) electronic, automatic reset
Protection of 42 VDC Out 2 output3 A (slow-blow) electronic, automatic reset
42 VDC Out 1 controller input
Electrical isolation / Input - 42 VDCYes
Input voltage / Nominal24 VDC
Input voltage / Maximum30 VDC
Switching threshold / Low (42 VDC Out 1 is switched on)<5 V
Switching threshold / High (42 VDC Out 1 is switched off)>15 V
Switching delay / ON (42 VDC Out 1 is switched on)Max. 25 ms
Switching delay / OFF (42 VDC Out 1 is switched off)Max. 0.25 ms
Terminal connection cross sections / Flexible and fine-stranded wires / With wire end sleeve0.25 to 2.5 mm²
Terminal connection cross sections / Approbation data / UL/C-UL-US22 to 12 AWG
Terminal connection cross sections / Approbation data / CSA22 to 12 AWG
CircuitSink
Modulation compared to ground potentialMax. ±50 V
Input current at nominal voltageApprox. 10 mA
VariantConnector
Operating conditions
Permissible mounting orientations / Hanging verticallyYes
Permissible mounting orientations / Horizontal, face upYes
Permissible mounting orientations / Standing horizontallyNo
Installation elevation above sea level / Nominal0 to 500 m
Installation elevation above sea level / Maximum4000 m
Pollution degree per EN 61800-5-12 (non-conductive pollution)
Overvoltage category per EN 61800-5-1III
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Nominal5 to 40°C
Temperature / Operation / Maximum55°C
Temperature / Storage-25 to 55°C
Temperature / Transport-25 to 70°C
Relative humidity / Operation5 to 85%
Relative humidity / Storage5 to 95%
Relative humidity / TransportMax. 95% at 40°C
Mechanical properties
Dimensions / Depth / Cold plate212 mm
Dimensions / Depth / Pass-through mounting209 mm
Dimensions / Width53 mm
Dimensions / Height317 mm
WeightApprox. 2.6 kg