IAC

B&R 8B0C0320HW00.B00-1

ACOPOSmulti auxiliary supply module, 35 A, AS, wall mounting, 42...58 VOut

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

Replacing or upgrading a servo component?

Servo amplifiers, motors, encoders and cables are matched sets. If this part is no longer available in its original form, the manufacturer's newer generation usually will not pair with the rest of the axis, so an upgrade normally covers the drive, motor and cables together. Send us the nameplate details and we will confirm availability of an exact spare or scope a compatible upgrade.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

General information
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / ULcULus E225616 Power conversion equipment
Cooling and mounting typeWall mounting
DC bus connection
Voltage / Nominal750 VDC
Voltage / Operating range in continuous operation260 to 800 VDC
Voltage / Full continuous power550 to 800 VDC
Continuous power consumptionMax. 2120 W
Power dissipation with continuous power15 W (0% continuous power) 30 W (50% continuous power) 90 W (100% continuous power)
DC bus capacitance1.2 µF
VariantACOPOSmulti backplane
24 VDC output
Output voltage / DC bus voltage (UDC): 260 to 315 VDC25 VDC * (UDC/315)
Output voltage / DC bus voltage (UDC): 315 to 800 VDC24 VDC ±6%
Variant / 24 VDC, COMConnector
Quantity1
Fuse protection250 mA (slow-blow) electronic, automatic reset
24 VDC internal system power supply
Input voltage25 VDC ±1.6%
Input capacitance47 µF
Max. power consumption7 W + P 24 VDC Out
VariantACOPOSmulti backplane
58 VDC output
Output voltage / Nominal58 VDC
Output voltage / Workspace42 to 58 VDC
Output voltage / Residual rippleTyp. 200 mVSS
Output voltage / Input stabilityTyp. <50 mV (dynamic)
Output voltage / Load stability250 mVSS (dynamic)
Reduction of continuous current / Depending on ambient temperature0.2 A/K (starting at 40°C)
Reduction of continuous current / Depending on installation elevation3.5 A per 1000 m (starting at 500 m above sea level)
Reduction of continuous current / Depending on the input voltage0.0732 A/V * (550 V - Input voltage)
Reduction of continuous current / Depending on cooling typeNo reduction
Reduction of peak current / Depending on the input voltage0,136 A/V * (600 V - Input voltage)
Protective measures / No-load proofYes
Protective measures / Overload-proofYes
Protective measures / Short-circuit proofYes
Protective measures / Feedback protectionYes <63 V
Protective measures / Overtemperature protectionYes
Protective measures / Output/Input isolationPELV
Quantity1
Continuous power(Output voltage / 58 VDC) * 2030 W
Continuous current±35 A
Peak current±60 A (max. 2 s)
Startup delayMax. 8 s
Startup timeTyp. 300 ms
VariantConnector
Shield connectionYes
ConnectionParallel connection on output: Not permitted Serial connection on output: Not permitted
Max. cable length30 m
Fieldbus
TypePOWERLINK V2 controlled node (CN)
Variant2x RJ45, shielded, 2-port hub
Line lengthMax. 100 m between 2 stations (segment length)
Transfer rate100 Mbit/s
Digital inputs
Input voltage / Nominal24 VDC
Input voltage / Maximum30 VDC
Switching delay / Rising edge52 ±0.5 µs (digitally filtered)
Switching delay / Falling edge53 ±0.5 µs (digitally filtered)
Quantity1
Modulation compared to ground potential±38 VDC
CircuitSink
Input current at nominal voltageTyp. 10 mA
Switching thresholdLOW: <5 VDC HIGH: >15 VDC
Electrical isolationYes
ShieldingNo
Max. cable length30 m
Signal loop through
Quantity2 pairs
VoltageMax. 30 VDC
CurrentMax. 100 mA
Electrical isolationYes
Loop through for STOYes
ShieldingNo
VariantPair1_1, Pair1_2, Pair2_1, Pair2_2
Max. cable length30 m
Battery voltage measurement
Input voltage / Maximum10 V
Measurement / Load pulse3 mA
Measurement / Pulse durationMax. 500 ms
Measurement / Threshold value for undervoltage warning5.2 V
Quantity1
Electrical isolationYes
Idle currentMax. 10 µA
VariantConnector
ShieldingNo
Max. cable length30 m
Support
Motion system / mapp Motion5.13.1 and higher
Motion system / ACP10/ARNC0All versions
Operating conditions
Permissible mounting orientations / Hanging verticallyYes
Permissible mounting orientations / Horizontal, face upYes
Permissible mounting orientations / Standing horizontallyNo
Installation elevation above sea level / Nominal0 to 500 m
Installation elevation above sea level / Maximum4000 m
Pollution degree per EN 61800-5-12 (non-conductive pollution)
Overvoltage category per EN 61800-5-1III
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Nominal5 to 40°C
Temperature / Operation / Maximum55°C
Temperature / Storage-25 to 55°C
Temperature / Transport-25 to 70°C
Relative humidity / Operation5 to 85%
Relative humidity / Storage5 to 95%
Relative humidity / TransportMax. 95% at 40°C
Mechanical properties
Dimensions / Depth / Wall mounting263 mm
Dimensions / Width53.5 mm
Dimensions / Height317 mm
Weight3.2 kg
Module width1

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.