IAC

B&R 8B0F0160H000.000-1

Wide mains input voltage range Optimized for ACOPOSmulti 8B0P power supply modules and ACOPOS P3 Compliance with limit values per CISPR11, group 2, class A In order to conform to the EMC limit values, all 8BVI inverter modules in the drive system connected to the 8B0F line filter must be operated at the nominal switching frequency (5 kHz). The total length of all motor cables on each drive system (and for each 8B0F line filter) is not permitted to exceed 250 m. The cable length between the 8B0F line filter and the 8B0P power supply module is not permitted to exceed 5 m. The maximum permissible motor cable length per motor connection must also be taken into account (see 8BVI inverter modules). Line filter, passive, 16 A, 3x 528 VAC, 50/60 Hz, IP20

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

Replacing or upgrading a servo component?

Servo amplifiers, motors, encoders and cables are matched sets. If this part is no longer available in its original form, the manufacturer's newer generation usually will not pair with the rest of the axis, so an upgrade normally covers the drive, motor and cables together. Send us the nameplate details and we will confirm availability of an exact spare or scope a compatible upgrade.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

General information
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)Not applicable
Certifications / ULUL E225616 Power conversion equipment
Certifications / UL #2cULus E225616 Power conversion equipment
Cooling and mounting typeWall mounting
Mains connection
Reduction of continuous current depending on ambient temperature / Starting at 50°C0.164 A/K
Reduction of continuous current depending on installation elevation / Starting at 2000 m above sea level15 A up to 3000 m 14.2 A up to 4000 m
Variant / Shield connection / On mainsNo
Variant / Shield connection / On deviceNo
Variant / L1, L2, L3 and L1´, L2´, L3´Terminals
Variant / PEM5 threaded bolt
Terminal connection cross section / Flexible and fine-stranded wires / With wire end sleeve0.25 to 6 mm²
Terminal connection cross section / Approbation data / UL/C-UL-US28 to 8 AWG
Terminal connection cross section / Approbation data / CSA28 to 8 AWG
Permissible network configurationsTT, TN
Mains input voltageMax. 3x 528 VAC
FrequencyMax. 60 Hz
Continuous current16 Aeff
Peak current24 Aeff (<1 min), 1x/h
Power dissipation6.1 W
Line filter per EN 61800-3, category C3Yes
Electrical properties
Discharge capacitance0.4 µF
Leakage current33 mA
Operating conditions
Permissible mounting orientations / Hanging verticallyYes
Permissible mounting orientations / Horizontal, face upYes
Permissible mounting orientations / Standing horizontallyYes
Installation elevation above sea level / Nominal0 to 2000 m
Installation elevation above sea level / Maximum4000 m
Pollution degree per EN 61800-5-1PD 3 per EN 61800-5-1 and IEC 60664-1
Overvoltage category per IEC 60950III
Overvoltage category per EN 61800-5-1III per EN 60664-1
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Nominal5 to 40°C
Temperature / Operation / Maximum55°C
Temperature / Storage-25 to 55°C
Temperature / Transport-25 to 70°C
Relative humidity / Operation5 to 85%
Relative humidity / Storage5 to 95%
Relative humidity / TransportMax. 95% at 40°C
Mechanical properties
Dimensions / Width45 mm
Dimensions / Height263.8 mm
Dimensions / Depth70 mm
Vibration and shock3M4 per IEC 60721-3-3
Weight0.85 kg

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.