B&R 8B0F0160H000.A00-1
Wide mains input voltage range Optimally suited for ACOPOSmulti 8B0P power supply modules Compliance with limit values per CISPR11, group 2, class A In order to conform to the EMC limit values, all 8BVI inverter modules in the drive system connected to the 8B0F line filter must be operated at the nominal switching frequency (5 kHz). The total length of all motor cables on each drive system (and for each 8B0F line filter) is not permitted to exceed 250 m. The cable length between the 8B0F line filter and the 8B0P power supply module is not permitted to exceed 5 m. The maximum permissible motor cable length per motor connection must also be taken into consideration (see 8BVI inverter modules). Line filter, passive, 16 A, 3x 480 VAC, 50/60 Hz, IP20
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
General information
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / UL | cULus E225616 Power conversion equipment |
| Cooling and mounting type | Wall mounting |
Mains connection
| Reduction of continuous current depending on ambient temperature / Starting at 50°C | 0.165 A/K |
| Reduction of continuous current depending on installation elevation / Starting at 1000 m above sea level | 0.8 Aeff per 1000 m |
| Variant / Shield connection / On mains | No |
| Variant / Shield connection / On device | No |
| Variant / L1, L2, L3 and L1´, L2´, L3´ | Terminals |
| Variant / PE | M5 threaded bolt |
| Terminal connection cross section / Flexible and fine-stranded wires / With wire end sleeve | Max. 4 mm² |
| Terminal connection cross section / Approbation data / UL/C-UL-US | 12 AWG |
| Terminal connection cross section / Approbation data / CSA | 12 AWG |
| Permissible network configurations | TT, TN |
| Mains input voltage | Max. 3x 480 VAC ±10% |
| Frequency | 0 to 60 Hz |
| Continuous current | 16 Aeff |
| Peak current | 24 Aeff (<1 min), 1x/h |
| Power dissipation | 6.1 W |
| Line filter per EN 61800-3, category C3 | Yes |
Electrical properties
| Discharge capacitance | 0.4 µF |
| Leakage current | 33 mA |
Operating conditions
| Permissible mounting orientations / Hanging vertically | Yes |
| Permissible mounting orientations / Horizontal, face up | Yes |
| Permissible mounting orientations / Standing horizontally | No |
| Installation elevation above sea level / Nominal | 0 to 1000 m |
| Installation elevation above sea level / Maximum | 4000 m |
| Pollution degree per EN 61800-5-1 | In preparation |
| Overvoltage category per IEC 60950 | II |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature / Operation / Nominal | 5 to 40°C |
| Temperature / Operation / Maximum | 55°C |
| Temperature / Storage | -25 to 55°C |
| Temperature / Transport | -25 to 70°C |
| Relative humidity / Operation | 5 to 85% |
| Relative humidity / Storage | 5 to 95% |
| Relative humidity / Transport | Max. 95% at 40°C |
Mechanical properties
| Dimensions / Width | 45 mm |
| Dimensions / Height | 250 mm |
| Dimensions / Depth | 70 mm |
| Weight | 0.8 kg |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
3D CAD models
ECAD / EPLAN
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.