B&R 8B0P0110HW00.000-1
Passive power supply modules act as the central power supply for ACOPOSmulti drives and feed the DC bus. They are not subjected to a control loop and therefore cannot provide regeneration. The 8B0P0110HC00.000-1 passive power supply module has an integrated line filter and internal braking resistor. It is also possible to connect an optional external braking resistor. In addition, an interface for connecting 24 VDC is also available. This allows the internal 24 VDC supply to provide an ACOPOSmulti drive system with up to 90 watts of nominal power. This eliminates the need for an 8B0C auxiliary supply module in many applications. The system can start either from external 24 VDC or mains power. ACOPOSmulti power supply module, passive, 11 A, AS, wall mounting, 24 V In 1x, integrated line filter
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
Servo amplifiers, motors, encoders and cables are matched sets. If this part is no longer available in its original form, the manufacturer's newer generation usually will not pair with the rest of the axis, so an upgrade normally covers the drive, motor and cables together. Send us the nameplate details and we will confirm availability of an exact spare or scope a compatible upgrade.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
General information
| Support / Dynamic node allocation (DNA) | Yes |
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | In preparation |
| Certifications / UL | cULus E225616 Power conversion equipment |
| B&R ID code | 0xDDAD |
| Cooling and mounting type | Wall mounting |
Mains connection
| Max. chargeable DC bus capacitance depending on mains voltage / 230 VAC | 9 mF |
| Max. chargeable DC bus capacitance depending on mains voltage / 400 VAC | 3 mF |
| Max. chargeable DC bus capacitance depending on mains voltage / 480 VAC | 2 mF |
| Variant / L1, L2, L3, PE | Connector |
| Variant / PE | M5 threaded bolt |
| Variant / Shield connection | No |
| Terminal connection cross section / Flexible and fine-stranded wires / With wire end sleeve | 0.5 to 6 mm² |
| Terminal connection cross section / Approbation data / UL/C-UL-US | 20 to 6 AWG |
| Terminal connection cross section / Approbation data / CSA | 20 to 6 AWG |
| Network configurations | TT, TN-S, TN-C-S |
| Mains input voltage | 3x 208 to 3x 480 VAC ±10% |
| Frequency | 50 / 60 Hz ±4% |
| Installed load | Max. 6.7 kVA |
| Power dissipation with continuous power | [2.8 * P² + 0.5 * P + 10] W |
| Inrush current at 400 VAC | 2 A |
| Switch-on interval | >120 s |
| Integrated line filter per EN 61800-3, category C3 | Yes |
| Integrated regeneration choke | No |
| Regenerative | No |
| Power factor correction (PFC) | No |
| Line fuse | Max. 33 A (gG fuses per IEC 60269-1 or Class CC, J, T) Max. 27.5 A (circuit breaker per EN 60947-2 or UL 489) |
| Terminal cable cross section dimension of shield connection | 23 to 35 mm |
DC bus connection
| Voltage / Nominal | 294 to 679 VDC |
| Reduction of continuous power depending on mains input voltage / Mains input voltage <3x 400 VAC | 10 W/V * (400 V - Mains input voltage) |
| Reduction of continuous power depending on installation elevation / Starting at 500 m above sea level | 0.4 kW per 1000 m |
| Protective measures / Overload protection | Yes |
| Protective measures / Short-circuit and ground fault protection | No |
| Continuous power | 4 kW |
| Reduction of continuous power depending on cooling method | No reduction |
| Peak power output (supply) | 12 kW |
| DC bus capacitance | 330 µF |
| Variant | ACOPOSmulti backplane |
24 VDC power supply
| Input voltage | 25 VDC ±1.6% |
| Input capacitance | 23.5 µF |
| Max. power consumption | 12 W |
| Variant | ACOPOSmulti backplane |
24 VDC In
| Input voltage / Minimum | 18 VDC |
| Input voltage / Nominal | 24 VDC |
| Input voltage / Maximum | 30 VDC |
| Protective measures / No-load proof | Yes |
| Protective measures / Overload-proof | Yes |
| Protective measures / Short-circuit proof | Yes |
| Protective measures / Overtemperature protection | Yes |
| Variant / 24 VDC In, COM | Connector |
| Terminal connection cross section of input "24 VDC In" / Flexible and fine-stranded wires / With wire end sleeves | 0.2 to 2.5 mm² |
| Terminal connection cross section of input "24 VDC In" / Approbation data / UL/C-UL-US | 30 to 12 AWG |
| Terminal connection cross section of input "24 VDC In" / Approbation data / CSA | 22 to 12 AWG |
| 24 VDC internal system power supply | 25 VDC ±1.6% (regulated) |
| Switch-on threshold | 16 V |
| Max. continuous current | 4.0 A |
| Status indicators | 24 V LED |
| Undervoltage detection | Yes |
| Overvoltage detection | Yes |
Motor holding brake connection
| Terminal connection cross section / Flexible and fine-stranded wires / With wire end sleeve | 0.25 to 6 mm² |
| Terminal connection cross section / Approbation data / UL/C-UL-US | 24 to 8 AWG |
| Terminal connection cross section / Approbation data / CSA | 24 to 8 AWG |
Braking resistor
| Variant / RB+, RB-, PE | Connector |
| Variant / Shield connection | Yes |
| Protective measures / Overload protection | Yes |
| Protective measures / Short-circuit and ground fault protection | Yes (with RB+ by externally replaceable melting fuse) |
| Peak power int./ext. | 2 kW / 24 kW (max. 1 s) |
| Continuous power int./ext. | 150 W / 8 kW |
| Min. braking resistance | 25 Ω |
| Rated current of built-in fuse | 15 A (fast-acting) |
| Terminal cable cross section dimension of shield connection | 23 to 35 mm |
Electrical properties
| Energy efficiency (IE classification) / Power dissipation relative to continuous apparent power | IE2 (10;25) 0.6% IE2 (50;25) 0.7% IE2 (10;50) 0.6% IE2 (50;50) 0.7% IE2 (90;50) 0.9% IE2 (10;100) 0.7% IE2 (50;100) 0.9% IE2 (90;100) 1.5% |
| Energy efficiency (IE classification) / Nominal losses in standby mode | 6 W |
| Discharge capacitance | 0.4 µF |
Operating conditions
| Permissible mounting orientations / Hanging vertically | Yes |
| Permissible mounting orientations / Horizontal, face up | Yes |
| Permissible mounting orientations / Standing horizontally | No |
| Installation elevation above sea level / Nominal | 0 to 500 m |
| Installation elevation above sea level / Maximum | 4000 m |
| Pollution degree per EN 61800-5-1 | 2 (non-conductive pollution) |
| Overvoltage category per EN 61800-5-1 | III |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature / Operation / Nominal | 5 to 40°C |
| Temperature / Operation / Maximum | 55°C |
| Temperature / Storage | -25 to 55°C |
| Temperature / Transport | -25 to 70°C |
| Relative humidity / Operation | 5 to 85% |
| Relative humidity / Storage | 5 to 95% |
| Relative humidity / Transport | Max. 95% at 40°C |
Mechanical properties
| Dimensions / Depth / Wall mounting | 263 mm |
| Dimensions / Width | 53.5 mm |
| Dimensions / Height | 317 mm |
| Weight | 3.5 kg |
| Module width | 1 |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
Manuals
3D CAD models
ECAD / EPLAN
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.