B&R 8B0P0440HW00.001-1
Wide input voltage range Integrated connection for external braking resistor Passive motor short circuit brake ACOPOSmulti power supply module passive, 44 A, AS, wall mounting, passive motor short circuit brake
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
Servo amplifiers, motors, encoders and cables are matched sets. If this part is no longer available in its original form, the manufacturer's newer generation usually will not pair with the rest of the axis, so an upgrade normally covers the drive, motor and cables together. Send us the nameplate details and we will confirm availability of an exact spare or scope a compatible upgrade.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
General information
| Support / Dynamic node allocation (DNA) | Yes |
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | In preparation |
| Certifications / UL | cULus E225616 Power conversion equipment |
| Certifications / KC | Yes |
| Note | Integrated passive motor short circuit brake |
| B&R ID code | 0xA989 |
| Cooling and mounting type | Wall mounting |
Mains connection
| Max. chargeable DC bus capacitance depending on mains voltage / 400 VAC | 14.4 mF |
| Max. chargeable DC bus capacitance depending on mains voltage / 480 VAC | 10 mF |
| Variant / L1, L2, L3, PE | Connector |
| Variant / PE | M5 threaded bolt |
| Variant / Shield connection | Yes |
| Terminal connection cross section / Flexible and fine-stranded wires / With wire end sleeve | 0.5 to 16 mm² |
| Terminal connection cross section / Approbation data / UL/C-UL-US | 20 to 6 AWG |
| Terminal connection cross section / Approbation data / CSA | 20 to 6 AWG |
| Network configurations | TT, TN-S, TN-C-S |
| Mains input voltage | 3x 380 to 3x 500 VAC ±10% |
| Frequency | 50 / 60 Hz ±4% |
| Installed load | Max. 30.4 kVA |
| Power dissipation with continuous power | Approx. 300 W |
| Inrush current at 400 VAC | 10 A |
| Switch-on interval | >120 s |
| Integrated line filter per EN 61800-3, category C3 | No |
| Integrated regeneration choke | No |
| Regenerative | No |
| Power factor correction (PFC) | No |
| Line fuse | Max. 132 A (gG fuses per IEC 60269-1 or Class CC, J, T) Max. 110 A (circuit breaker per EN 60947-2 or UL 489) |
| Terminal cable cross section dimension of shield connection | 23 to 35 mm |
DC bus connection
| Voltage / Nominal | 537 to 707 VDC |
| Reduction of continuous power depending on mains input voltage / Mains input voltage <3x 400 VAC | 40 W/V * (400 V - Mains input voltage) |
| Reduction of continuous power depending on installation elevation / Starting at 500 m above sea level | 1.6 kW per 1000 m |
| Protective measures / Overload protection | Yes |
| Protective measures / Short-circuit and ground fault protection | No |
| Continuous power | 16 kW |
| Reduction of continuous power depending on cooling method | In preparation |
| Peak power output (supply) | 48 kW |
| Power dissipation with continuous power | In preparation |
| DC bus capacitance | 1320 µF |
| Variant | ACOPOSmulti backplane |
24 VDC power supply
| Input voltage | 25 VDC ±1.6% |
| Input capacitance | 23.5 µF |
| Max. power consumption | 12 W |
| Variant | ACOPOSmulti backplane |
Motor holding brake connection
| Terminal connection cross section / Flexible and fine-stranded wires / With wire end sleeve | 0.5 to 6 mm² |
| Terminal connection cross section / Approbation data / UL/C-UL-US | 20 to 6 AWG |
| Terminal connection cross section / Approbation data / CSA | 20 to 6 AWG |
Braking resistor
| Variant / RB+, RB-, PE | Connector |
| Variant / Shield connection | Yes |
| Protective measures / Overload protection | Yes |
| Protective measures / Short-circuit and ground fault protection | Yes (with RB+ by externally replaceable melting fuse) |
| Peak power output | 65 kW (max. 1 s) |
| Continuous power | 3 kW |
| Min. braking resistance | 7.5 Ω |
| Rated current of built-in fuse | 30 A (fast-acting) |
| Terminal cable cross section dimension of shield connection | 23 to 35 mm |
Electrical properties
| Energy efficiency (IE classification) / Power dissipation relative to continuous apparent power | IE2 (10;25) 0.2% IE2 (50;25) 0.3% IE2 (10;50) 0.2% IE2 (50;50) 0.3% IE2 (90;50) 0.6% IE2 (10;100) 0.3% IE2 (50;100) 0.6% IE2 (90;100) 1.3% |
| Energy efficiency (IE classification) / Nominal losses in standby mode | 6 W |
| Discharge capacitance | 0.9 µF |
Operating conditions
| Permissible mounting orientations / Hanging vertically | Yes |
| Permissible mounting orientations / Horizontal, face up | Yes |
| Permissible mounting orientations / Standing horizontally | No |
| Installation elevation above sea level / Nominal | 0 to 500 m |
| Installation elevation above sea level / Maximum | 4000 m |
| Pollution degree per EN 61800-5-1 | 2 (non-conductive pollution) |
| Overvoltage category per EN 61800-5-1 | III |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature / Operation / Nominal | 5 to 40°C |
| Temperature / Operation / Maximum | 55°C |
| Temperature / Storage | -25 to 55°C |
| Temperature / Transport | -25 to 70°C |
| Relative humidity / Operation | 5 to 85% |
| Relative humidity / Storage | 5 to 95% |
| Relative humidity / Transport | Max. 95% at 40°C |
Mechanical properties
| Dimensions / Depth / Wall mounting | 263 mm |
| Dimensions / Width | 106.5 mm |
| Dimensions / Height | 317 mm |
| Weight | Approx. 6.1 kg |
| Module width | 2 |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
Manuals
3D CAD models
ECAD / EPLAN
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.