B&R 8BCA01X5.1111A-0
UL/CSA listed Can be used in cable drag chains Assembled specifically for DC connection between ACOPOSmulti expansion modules 8BVE Integrated shield plates ACOPOSmulti expansion cable, length 1.5 m, 3x 1.5 mm², integrated shield plate, can be used in cable drag chains
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
Servo amplifiers, motors, encoders and cables are matched sets. If this part is no longer available in its original form, the manufacturer's newer generation usually will not pair with the rest of the axis, so an upgrade normally covers the drive, motor and cables together. Send us the nameplate details and we will confirm availability of an exact spare or scope a compatible upgrade.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
General information
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | Not applicable |
| Certifications / UL | cULus E225616 Power conversion equipment |
| Cable cross section | 3x 1.5 mm² |
| Durability | Oil resistance per HD 22.10 appendix A DIN EN 60811-404 |
Cable construction
| Power lines / Quantity | 3 |
| Power lines / Wire insulation | PP |
| Power lines / Wire colors | Black, brown, yellow/green |
| Power lines / Variant | Tinned copper stranded wire |
| Power lines / Cross section | 1.5 mm² |
| Power lines / Shield | No |
| Power lines / Stranding | No |
| Outer jacket / Material | TPU |
| Outer jacket / Color | Orange, similar to RAL 2003 flat |
| Cable stranding | With filler elements and foil shield |
| Cable shield | Tinned copper braiding, optical coverage >85% and foil shield |
Electrical properties
| Test voltage / Wire - Wire | 4 kV |
| Test voltage / Wire - Shield | 4 kV |
| Conductor resistance / Power lines | ≤13.7 Ω/km |
| Current-carrying capacity per DIN VDE 0298 part 4, table 11 / Wall mounting | 20 A |
| Current-carrying capacity per DIN VDE 0298 part 4, table 11 / Installed in conduit or cable duct | 17.8 A |
| Current-carrying capacity per DIN VDE 0298 part 4, table 11 / Installed in cable tray | 20.9 A |
| Operating voltage | Max. 1000 VAC (UL) |
| Insulation resistance | ≥500 MΩ*km |
Ambient conditions
| Temperature / Moving | -20°C to +80°C |
| Temperature / Static | -20°C to +90°C |
Mechanical properties
| Dimensions / Length | 1.5 m |
| Dimensions / Diameter | 12.2 mm ±0.3 mm |
| Bend radius / Single bend | >38 mm |
| Bend radius / Moving | >94 mm |
| Drag chain data / Acceleration | Max. 50 m/s² (depends on the length of the travel path) |
| Drag chain data / Flex cycles | ≥5,000,000 |
| Drag chain data / Velocity | Max. 300 m/min |
| Weight | 0.2 kg |
Documentation & CAD