IAC

B&R 8BCM0020.15250-0

UL/CSA listed Can be used in cable drag chains Assembled specifically for motor cables 8BCMxxxx.1523A-0 with standard size 1.5 connector speedtec - Innovative connector system for secure connections Cable extension for 10 mm² motor cables with speedtec/standard connector size 1.5, length 20 m, can be used in cable drag chains

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

General information
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)Not applicable
Certifications / ULcULus E225616 Power conversion equipment
Cable cross section4x 10 mm² + (2x 0.75 mm²)C + (2x 1.5 mm²)C
DurabilityOil resistance per HD 22.10 appendix A DIN EN 60811-404
Cable construction
Power lines / Quantity4
Power lines / Wire insulationPP
Power lines / Wire colorsBlack, brown, blue, yellow/green
Power lines / VariantTinned copper stranded wire
Power lines / Cross section10 mm²
Power lines / ShieldNo
Power lines / StrandingNo
Signal line / Quantity4
Signal line / Wire insulationPP
Signal line / Wire colorsWhite, white/red, white/blue, white/green
Signal line / VariantTinned copper stranded wire
Signal line / Cross section2x 0.75 mm² + 2x 1.5 mm²
Signal line / ShieldIndividually shielded in pairs, tinned copper braiding, optical coverage >85% and foil shield
Signal line / StrandingWhite with white/red and white/blue with white/green
Outer jacket / MaterialTPU
Outer jacket / ColorOrange, similar to RAL 2003 flat
Cable strandingWith filler elements and foil shield
Cable shieldTinned copper braiding, optical coverage >85% and foil shield
Connector
Type8-pin female speedtec motor connector, size 1.5
Mating cycles<500
Contacts8 (4 power and 4 signal contacts)
Additional connectors8-pin male coupling Mating cycles: <500 Contacts: 8 Degree of protection per EN 60529: IP66/67 when connected
Degree of protection per EN 60529IP66/67 when connected
Electrical properties
Test voltage / Wire - Wire4 kV
Test voltage / Wire - Shield4 kV
Conductor resistance / Power lines≤2 Ω/km
Conductor resistance / Signal line0.75 mm²: ≤26.7 Ω/km, 1.5 mm²: ≤13.7 Ω/km
Current-carrying capacity per DIN VDE 0298 part 4, table 11 / Wall mounting64.6 A
Current-carrying capacity per DIN VDE 0298 part 4, table 11 / Installed in conduit or cable duct54.6 A
Current-carrying capacity per DIN VDE 0298 part 4, table 11 / Installed in cable tray68.3 A
Operating voltageMax. 1000 VAC (UL)
Insulation resistance≥500 MΩ*km
Ambient conditions
Temperature / Moving-20°C to +80°C
Temperature / Static-20°C to +90°C
Mechanical properties
Dimensions / Length20 m
Dimensions / Diameter20.1 mm ±0.4 mm
Bend radius / Single bend>62 mm
Bend radius / Moving>154 mm
Drag chain data / AccelerationMax. 50 m/s² (depends on the length of the travel path)
Drag chain data / Flex cycles≥5,000,000
Drag chain data / VelocityMax. 300 m/min
Weight10.8 kg

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.