IAC

B&R 8BVE0500HW00.000-1

For distributing the DC bus power supply and 24 VDC auxiliary supply to multiple mounting plates For setting up decentralized units in the ACOPOSmulti drive system Output for overload protection ACOPOSmulti expansion module 40 A, AS, wall mounting

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

Replacing or upgrading a servo component?

Servo amplifiers, motors, encoders and cables are matched sets. If this part is no longer available in its original form, the manufacturer's newer generation usually will not pair with the rest of the axis, so an upgrade normally covers the drive, motor and cables together. Send us the nameplate details and we will confirm availability of an exact spare or scope a compatible upgrade.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

General information
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)Not applicable
Certifications / ULcULus E225616 Power conversion equipment
Certifications / KCYes
Cooling and mounting typeWall mounting
DC bus connection
Voltage / Nominal750 VDC
Continuous power depending on fuse / 10 A6 kW
Continuous power depending on fuse / 20 A12 kW
Continuous power depending on fuse / 50 A30 kW
Continuous current depending on fuse / 10 A8 Aeff
Continuous current depending on fuse / 20 A16 Aeff
Continuous current depending on fuse / 50 A40 Aeff
Reduction of continuous power depending on installation elevation / Starting at 500 m above sea level10% per 1000 m
Peak current depending on fuse / 10 A20 A
Peak current depending on fuse / 20 A40 A
Peak current depending on fuse / 50 A100 A
Reduction of continuous power at ambient temperatures starting at 40°C1.25% per °Kelvin
Reduction of continuous power depending on cooling methodNo reduction
Power dissipation with continuous power200 W
VariantACOPOSmulti backplane
24 VDC power supply
Continuous power depending on fuse / 12 A240 W
Continuous power depending on fuse / 20 A400 W
Continuous power depending on fuse / 30 A600 W
Input voltage25 VDC ±1.6%
Max. power consumption5 W
Reduction of continuous power at ambient temperatures starting at 40°C1.25% per °Kelvin
VariantACOPOSmulti backplane
DC bus cable outlet
Fuse protection / Type2x melting fuse ø 14 x 51 mm
Fuse protection / Tripping characteristicUltra fast-acting
Fuse protection / Rated current10 / 20 / 50 A
Protective measures / Fuse-dependent overload protection / 10 ANo (overload indicated via LED, dry alarm contacts present)
Protective measures / Fuse-dependent overload protection / 20 ANo (overload indicated via LED, dry alarm contacts present)
Protective measures / Fuse-dependent overload protection / 50 ANo (overload indicated via LED, dry alarm contacts present)
Protective measures / Short-circuit and ground fault protectionYes
Variant / DC+, DC-, PEConnector
Variant / Shield connectionYes
Terminal connection cross section / Flexible and fine-stranded wires / With wire end sleeve0.5 to 16 mm²
Terminal connection cross section / Approbation data / UL/C-UL-US20 to 6 AWG
Terminal connection cross section / Approbation data / CSA20 to 6 AWG
Quantity2
Max. line length between two expansion modules5 m
Terminal cable cross section dimension of shield connection12 to 22 mm
24 VDC auxiliary supply cable outlet
Output voltage / DC bus voltage (UDC): 260 to 315 VDC25 VDC * (DC bus voltage / 315)
Output voltage / DC bus voltage (UDC): 315 to 800 VDC24 VDC ±6%
Fuse protection / TypeMelting fuse ø 10 x 38 mm
Fuse protection / Tripping characteristicFast-acting
Fuse protection / Rated current12 / 30 A
Protective measures / Overload protectionYes
Protective measures / Short-circuit proofYes
Variant / 24 VDC, COMConnector
Variant / Shield connectionNo
Terminal connection cross section / Flexible and fine-stranded wires / With wire end sleeve0.25 to 6 mm²
Terminal connection cross section / Approbation data / UL/C-UL-US22 to 10 AWG
Terminal connection cross section / Approbation data / CSA22 to 10 AWG
Quantity2
Max. line length between two expansion modules5 m
Alarm contacts
Type / Alarm contact 1Normally closed contact
Type / Alarm contact 2Normally open contact
Electrical isolation / Alarm contact - ACOPOSmulti moduleYes
Electrical isolation / Alarm contact - Alarm contactYes
Protection / Overload-proofNo
Protection / Short-circuit proofNo
Quantity2
Nominal voltage30 VDC
Maximum current1 A
Switching delay3 ms
Max. number of switching cycles100,000
Operating conditions
Permissible mounting orientations / Hanging verticallyYes
Permissible mounting orientations / Horizontal, face upYes
Permissible mounting orientations / Standing horizontallyNo
Installation elevation above sea level / Nominal0 to 500 m
Installation elevation above sea level / Maximum4000 m
Pollution degree per EN 61800-5-12 (non-conductive pollution)
Overvoltage category per EN 61800-5-1III
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Nominal5 to 40°C
Temperature / Operation / Maximum55°C
Temperature / Storage-25 to 55°C
Temperature / Transport-25 to 70°C
Relative humidity / Operation5 to 85%
Relative humidity / Storage5 to 95%
Relative humidity / TransportMax. 95% at 40°C
Mechanical properties
Dimensions / Depth / Wall mounting263 mm
Dimensions / Width53 mm
Dimensions / Height317 mm
WeightApprox. 3.1 kg
Module width1

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.