Servo amplifiers, motors, encoders and cables are matched sets. If this part is no longer available in its original form, the manufacturer's newer generation usually will not pair with the rest of the axis, so an upgrade normally covers the drive, motor and cables together. Send us the nameplate details and we will confirm availability of an exact spare or scope a compatible upgrade.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
General information
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | Not applicable |
| Certifications / UL | cULus E225616 Power conversion equipment |
| Certifications / KC | Yes |
| Cooling and mounting type | Wall mounting |
DC bus connection
| Voltage / Nominal | 750 VDC |
| Continuous power depending on fuse / 10 A | 6 kW |
| Continuous power depending on fuse / 20 A | 12 kW |
| Continuous power depending on fuse / 50 A | 30 kW |
| Continuous current depending on fuse / 10 A | 8 Aeff |
| Continuous current depending on fuse / 20 A | 16 Aeff |
| Continuous current depending on fuse / 50 A | 40 Aeff |
| Reduction of continuous power depending on installation elevation / Starting at 500 m above sea level | 10% per 1000 m |
| Peak current depending on fuse / 10 A | 20 A |
| Peak current depending on fuse / 20 A | 40 A |
| Peak current depending on fuse / 50 A | 100 A |
| Reduction of continuous power at ambient temperatures starting at 40°C | 1.25% per °Kelvin |
| Reduction of continuous power depending on cooling method | No reduction |
| Power dissipation with continuous power | 200 W |
| Variant | ACOPOSmulti backplane |
24 VDC power supply
| Continuous power depending on fuse / 12 A | 240 W |
| Continuous power depending on fuse / 20 A | 400 W |
| Continuous power depending on fuse / 30 A | 600 W |
| Input voltage | 25 VDC ±1.6% |
| Max. power consumption | 5 W |
| Reduction of continuous power at ambient temperatures starting at 40°C | 1.25% per °Kelvin |
| Variant | ACOPOSmulti backplane |
DC bus cable outlet
| Fuse protection / Type | 2x melting fuse ø 14 x 51 mm |
| Fuse protection / Tripping characteristic | Ultra fast-acting |
| Fuse protection / Rated current | 10 / 20 / 50 A |
| Protective measures / Fuse-dependent overload protection / 10 A | No (overload indicated via LED, dry alarm contacts present) |
| Protective measures / Fuse-dependent overload protection / 20 A | No (overload indicated via LED, dry alarm contacts present) |
| Protective measures / Fuse-dependent overload protection / 50 A | No (overload indicated via LED, dry alarm contacts present) |
| Protective measures / Short-circuit and ground fault protection | Yes |
| Variant / DC+, DC-, PE | Connector |
| Variant / Shield connection | Yes |
| Terminal connection cross section / Flexible and fine-stranded wires / With wire end sleeve | 0.5 to 16 mm² |
| Terminal connection cross section / Approbation data / UL/C-UL-US | 20 to 6 AWG |
| Terminal connection cross section / Approbation data / CSA | 20 to 6 AWG |
| Quantity | 2 |
| Max. line length between two expansion modules | 5 m |
| Terminal cable cross section dimension of shield connection | 12 to 22 mm |
24 VDC auxiliary supply cable outlet
| Output voltage / DC bus voltage (UDC): 260 to 315 VDC | 25 VDC * (DC bus voltage / 315) |
| Output voltage / DC bus voltage (UDC): 315 to 800 VDC | 24 VDC ±6% |
| Fuse protection / Type | Melting fuse ø 10 x 38 mm |
| Fuse protection / Tripping characteristic | Fast-acting |
| Fuse protection / Rated current | 12 / 30 A |
| Protective measures / Overload protection | Yes |
| Protective measures / Short-circuit proof | Yes |
| Variant / 24 VDC, COM | Connector |
| Variant / Shield connection | No |
| Terminal connection cross section / Flexible and fine-stranded wires / With wire end sleeve | 0.25 to 6 mm² |
| Terminal connection cross section / Approbation data / UL/C-UL-US | 22 to 10 AWG |
| Terminal connection cross section / Approbation data / CSA | 22 to 10 AWG |
| Quantity | 2 |
| Max. line length between two expansion modules | 5 m |
Alarm contacts
| Type / Alarm contact 1 | Normally closed contact |
| Type / Alarm contact 2 | Normally open contact |
| Electrical isolation / Alarm contact - ACOPOSmulti module | Yes |
| Electrical isolation / Alarm contact - Alarm contact | Yes |
| Protection / Overload-proof | No |
| Protection / Short-circuit proof | No |
| Quantity | 2 |
| Nominal voltage | 30 VDC |
| Maximum current | 1 A |
| Switching delay | 3 ms |
| Max. number of switching cycles | 100,000 |
Operating conditions
| Permissible mounting orientations / Hanging vertically | Yes |
| Permissible mounting orientations / Horizontal, face up | Yes |
| Permissible mounting orientations / Standing horizontally | No |
| Installation elevation above sea level / Nominal | 0 to 500 m |
| Installation elevation above sea level / Maximum | 4000 m |
| Pollution degree per EN 61800-5-1 | 2 (non-conductive pollution) |
| Overvoltage category per EN 61800-5-1 | III |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature / Operation / Nominal | 5 to 40°C |
| Temperature / Operation / Maximum | 55°C |
| Temperature / Storage | -25 to 55°C |
| Temperature / Transport | -25 to 70°C |
| Relative humidity / Operation | 5 to 85% |
| Relative humidity / Storage | 5 to 95% |
| Relative humidity / Transport | Max. 95% at 40°C |
Mechanical properties
| Dimensions / Depth / Wall mounting | 263 mm |
| Dimensions / Width | 53 mm |
| Dimensions / Height | 317 mm |
| Weight | Approx. 3.1 kg |
| Module width | 1 |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
Manuals
3D CAD models
ECAD / EPLAN
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.