IAC

B&R 8BVI0014HCS0.000-3

ACOPOSmulti3 inverter module, 1.9 A, AS, cold plate or pass-through mounting, optimized for applications with decentralized, computationally intensive open-loop and closed-loop control requirements

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

Replacing or upgrading a servo component?

Servo amplifiers, motors, encoders and cables are matched sets. If this part is no longer available in its original form, the manufacturer's newer generation usually will not pair with the rest of the axis, so an upgrade normally covers the drive, motor and cables together. Send us the nameplate details and we will confirm availability of an exact spare or scope a compatible upgrade.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

General information
System requirements / Automation Studio4.6.1.x or later
Certification / CEYes
Certification / KCYes
Certification / FSCYes
B&R ID code0x2F4E
Cooling and mounting methodCold plate or pass-through mounting
Slots for plug-in modules2
DC bus connection
Voltage / Nominal750 VDC
Power loss depending on the switching frequency / Switching frequency 5 kHz[0.6 * IM² + 1.3 * IM + 60] W
Power loss depending on the switching frequency / Switching frequency 10 kHz[0.97 * IM² + 0.5 * IM + 110] W
Power loss depending on the switching frequency / Switching frequency 20 kHz[1.7 * IM² - 0.7 * IM + 225] W
Continuous power consumption1.46 kW
DC bus capacitance165 µF
DesignACOPOSmulti backplane
24 VDC supply
Input voltage25 VDC ±1.6%
Input capacitance23.5 µF
Max. power consumption12 W + PSLOT1 + PSLOT2 + P24 V Out + PHoldingBrake
DesignACOPOSmulti backplane
24 VDC output
Output voltage / DC bus voltage (UDC): 260 to 315 VDC25 VDC * (UDC/315)
Output voltage / DC bus voltage (UDC): 315 to 800 VDC24 VDC ±6%
Quantity2
Protection250 mA (slow-blow) electronic, automatic reset
Motor connection
Reduction of continuous current depending on the switching frequency and mounting method / Switching frequency 5 kHz / Cold plate mountingNo reduction
Reduction of continuous current depending on the switching frequency and mounting method / Switching frequency 5 kHz / Feed-through mountingNo reduction
Reduction of continuous current depending on the switching frequency and mounting method / Switching frequency 10 kHz / Cold plate mountingNo reduction
Reduction of continuous current depending on the switching frequency and mounting method / Switching frequency 10 kHz / Feed-through mountingNo reduction
Reduction of continuous current depending on the switching frequency and mounting method / Switching frequency 20 kHz / Cold plate mounting0.13 A/K (starting at 46°C)
Reduction of continuous current depending on the switching frequency and mounting method / Switching frequency 20 kHz / Feed-through mounting0.1 A/K (starting at 41°C)
Reduction of continuous current depending on the installation elevation / Starting at 500 m above sea level0.19 Aeff per 1000 m
Protective measures / Overload protectionYes
Protective measures / Short circuit and ground fault protectionYes
Design / U, V, W, PEConnector
Design / Shield connectionYes
Terminal connection cross section / Flexible and fine wire lines / With wire end sleeves0.25 to 6 mm²
Terminal connection cross section / Approbation data / UL/C-UL-US30 to 10 AWG
Terminal connection cross section / Approbation data / CSA28 to 10 AWG
Max. motor line length depending on the switching frequency / Switching frequency 5 kHz25 m
Max. motor line length depending on the switching frequency / Switching frequency 10 kHz25 m
Max. motor line length depending on the switching frequency / Switching frequency 20 kHz10 m
Quantity1
Continuous power per motor connection1.4 kW
Continuous current per motor connection1.9 Aeff
Peak current4.7 Aeff
Nominal switching frequency5 kHz
Possible switching frequencies5 / 10 / 20 kHz
Electrical stress of the connected motor in accordance with IEC TS 60034-25Limit value curve A
Max. output frequency598 Hz
Terminal cable cross section dimension of shield connection12 to 22 mm
Motor holding brake connection
Protective measures / Overload and short circuit protectionYes
Protective measures / Open line monitoringYes
Protective measures / Undervoltage monitoringYes
Quantity1
Output voltage24 VDC +5.8% / -0%
Continuous current1.1 A
Max. internal resistance0.5 Ω
Extinction potentialApprox. 30 V
Max. extinction energy per switching operation1.5 Ws
Max. switching frequency0.5 Hz
Response threshold for open line monitoringApprox. 0.25 A
Response threshold for undervoltage monitoring24 VDC +0% / -4%
Enable inputs
Electrical isolation / Input - Inverter moduleYes
Electrical isolation / Input - InputYes
Input voltage / Nominal24 VDC
Input voltage / Maximum30 VDC
Switching threshold / Low<5 V
Switching threshold / High>15 V
Switching delay at nominal input voltage / Enable 1 -> 0, PWM offMax. 20.5 ms
Switching delay at nominal input voltage / Enable 0 -> 1, ready for PWMMax. 100 µs
Quantity2
WiringSink
Input current at nominal voltageApprox. 30 mA
Modulation compared to ground potentialMax. ±38 V
OSSD signal connectionsPermitted Max. test pulse length: 500 µs
Trigger inputs
Electrical isolation / Input - Inverter moduleYes
Electrical isolation / Input - InputYes
Input voltage / Nominal24 VDC
Input voltage / Maximum30 VDC
Switching threshold / Low<5 V
Switching threshold / High>15 V
Switching delay / Rising edge52 µs ±0.5 µs (digitally filtered)
Switching delay / Falling edge53 µs ±0.5 µs (digitally filtered)
Quantity2
WiringSink
Input current at nominal voltageApprox. 10 mA
Modulation compared to ground potentialMax. ±38 V
Electrical characteristics
Discharge capacitance0.14 µF
Operating conditions
Permitted mounting orientations / Hanging verticallyYes
Permitted mounting orientations / Lying horizontallyYes
Permitted mounting orientations / Standing horizontallyNo
Installation at elevations above sea level / Nominal0 to 500 m
Installation at elevations above sea level / Maximum4000 m
Degree of pollution in accordance with EN 60664-12 (non-conductive pollution)
Overvoltage category in accordance with IEC 60364-4-443:1999III
EN 60529 protectionIP20
Environmental conditions
Temperature / Operation / Nominal5 to 40°C
Temperature / Operation / Maximum55°C
Temperature / Storage-25 to 55°C
Temperature / Transport-25 to 70°C
Relative humidity / Operation5 to 85%
Relative humidity / Storage5 to 95%
Relative humidity / TransportMax. 95% at 40°C
Mechanical characteristics
Dimensions / Depth / Cold plate212 mm
Dimensions / Depth / Feed-through mounting209 mm
Dimensions / Width53 mm
Dimensions / Height317 mm
WeightApprox. 2.1 kg
Module width1

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.