IAC

B&R 8BVI0220HWSS.000-4

ACOPOSmulti3 SafeMOTION EnDat 2.2 Gen2 inverter module, 22 A, AS, wall mounting, optimized for applications with decentralized, computationally intensive open-loop and closed-loop control requirements

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

Replacing or upgrading a servo component?

Servo amplifiers, motors, encoders and cables are matched sets. If this part is no longer available in its original form, the manufacturer's newer generation usually will not pair with the rest of the axis, so an upgrade normally covers the drive, motor and cables together. Send us the nameplate details and we will confirm availability of an exact spare or scope a compatible upgrade.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

General information
System requirements / Automation Studio4.6.1.x or later
System requirements / mapp Technology Packagemapp Safety 5.24.0 or later
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / Functional safetyYes (openSAFETY)
Certifications / ULcULus E225616 Power conversion equipment
Certifications / KCYes
B&R ID code0x2FD8
Cooling and mounting typeWall mounting
Slots for plug-in modules2
DC bus connection
Voltage / Nominal750 VDC
Power dissipation depending on switching frequency / Switching frequency 5 kHz[0.13 * IM² + 5.5 * IM + 40] W
Power dissipation depending on switching frequency / Switching frequency 10 kHz[0.43 * IM² + 3.7 * IM + 110] W
Power dissipation depending on switching frequency / Switching frequency 20 kHz[1.4 * IM² + 1.97 * IM + 230] W
Continuous power consumption16.2 kW
DC bus capacitance495 µF
VariantACOPOSmulti backplane
24 VDC power supply
Input voltage25 VDC ±1.6%
Input capacitance32.9 µF
Max. power consumption26 W + PSMC1 + PSLOT2 + P24 V Out + PHoldingBrake
VariantACOPOSmulti backplane
24 VDC output
Output voltage / DC bus voltage (UDC): 260 to 315 VDC25 VDC * (UDC/315)
Output voltage / DC bus voltage (UDC): 315 to 800 VDC24 VDC ±6%
Quantity2
Fuse protection250 mA (slow-blow) electronic, automatic reset
Motor connection
Reduction of continuous current depending on switching frequency / Switching frequency 5 kHzNo reduction
Reduction of continuous current depending on switching frequency / Switching frequency 10 kHz0.4 A/K (starting at 31°C)
Reduction of continuous current depending on switching frequency / Switching frequency 20 kHz0.31 A/K (starting at -16°C)
Reduction of continuous current depending on installation elevation / Starting at 500 m above sea level2.2 Aeff per 1000 m
Protective measures / Overload protectionYes
Protective measures / Short-circuit and ground fault protectionYes
Variant / U, V, W, PEConnector
Variant / Shield connectionYes
Terminal connection cross section / Flexible and fine-stranded wires / With wire end sleeve0.5 to 6 mm²
Terminal connection cross section / Approbation data / UL/C-UL-US20 to 8
Terminal connection cross section / Approbation data / CSA20 to 8
Max. motor line length depending on switching frequency / Switching frequency 5 kHz25 m
Max. motor line length depending on switching frequency / Switching frequency 10 kHz25 m
Max. motor line length depending on switching frequency / Switching frequency 20 kHz25 m
Quantity1
Continuous power per motor connection16 kW
Continuous current per motor connection22 Aeff
Peak current55 Aeff
Nominal switching frequency5 kHz
Possible switching frequencies5 / 10 / 20 kHz
Insulation stress of the connected motor per IEC TS 60034-25:2004Limit value curve A
Max. output frequency598 Hz
Terminal cable cross section dimension of shield connection12 to 22 mm
Motor holding brake connection
Protective measures / Overload and short-circuit protectionYes
Protective measures / Open-circuit monitoringYes
Protective measures / Undervoltage monitoringYes
Quantity1
Output voltage24 VDC +5.8% / -0.5%
Continuous current per connection4.2 A
Max. internal resistance0.15 Ω
Extinction potentialApprox. 30 V
Max. extinction energy per switching operation3 Ws
Max. switching frequency0.5 Hz
Response threshold for open-circuit monitoringApprox. 0.5 A
Response threshold for undervoltage monitoring24 VDC -2% / -4%
Encoder interfaces
Electrical isolation / Encoder - ACOPOSmultiNo
Encoder power supply / Protective measures / Short-circuit proofYes
Encoder power supply / Protective measures / Overload-proofYes
Encoder power supply / Output voltageTyp. 12.5 V
Encoder power supply / Load capacity350 mA
Synchronous serial interface / Signal transmissionRS485
Synchronous serial interface / Data transfer rate6.25 Mbit/s
Quantity1
TypeEnDat 2.2
Connections9-pin female DSUB connector
Status indicatorsUP/DN LEDs
Encoder monitoringYes
Max. encoder cable length100 m Depends on the cross section of the power supply wires in the encoder cable
Max. power consumption per encoder interfacePSMC[W] = 19 V * IEncoder[A]
Trigger inputs
Electrical isolation / Input - Inverter moduleYes
Electrical isolation / Input - InputYes
Input voltage / Nominal24 VDC
Input voltage / Maximum30 VDC
Switching threshold / Low<5 V
Switching threshold / High>15 V
Switching delay / Rising edge52 µs ±0.5 µs (digitally filtered)
Switching delay / Falling edge53 µs ±0.5 µs (digitally filtered)
Quantity2
CircuitSink
Input current at nominal voltageApprox. 10 mA
Modulation compared to ground potentialMax. ±38 V
Temperature sensor connection
Quantity1
Resistance range500 Ω to 5 kΩ
Support
Motion system / mapp Motion5.24.1 and higher
Motion system / ACP10/ARNC05.24.1 and higher
Electrical properties
Energy efficiency (IE classification) / Power dissipation relative to continuous apparent powerIE2 (10,25) 1.4% IE2 (50,25) 1.4% IE2 (10,50) 1.6% IE2 (50,50) 1.6% IE2 (90,50) 1.6% IE2 (10,100) 2.3% IE2 (50,100) 2.3% IE2 (90,100) 2.3%
Energy efficiency (IE classification) / Nominal losses in standby mode12.3 W
Discharge capacitance0.22 µF
Operating conditions
Permissible mounting orientations / Hanging verticallyYes
Permissible mounting orientations / Horizontal, face upYes
Permissible mounting orientations / Standing horizontallyNo
Installation elevation above sea level / Nominal0 to 500 m
Installation elevation above sea level / Maximum4000 m
Pollution degree per EN 61800-5-12 (non-conductive pollution)
Overvoltage category per EN 61800-5-1III
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Nominal5 to 40°C
Temperature / Operation / Maximum55°C
Temperature / Storage-25 to 55°C
Temperature / Transport-25 to 70°C
Relative humidity / Operation5 to 85%
Relative humidity / Storage5 to 95%
Relative humidity / TransportMax. 95% at 40°C
Mechanical properties
Dimensions / Depth / Wall mounting263 mm
Dimensions / Width106.5 mm
Dimensions / Height317 mm
WeightApprox. 5.2 kg
Module width2

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.