B&R 8BVI0660HWS0.008-1
ACOPOSmulti inverter module, 66 A, AS, wall mounting
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
Servo amplifiers, motors, encoders and cables are matched sets. If this part is no longer available in its original form, the manufacturer's newer generation usually will not pair with the rest of the axis, so an upgrade normally covers the drive, motor and cables together. Send us the nameplate details and we will confirm availability of an exact spare or scope a compatible upgrade.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
General information
| Support / Dynamic node allocation (DNA) | Yes |
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | Evaluation ongoing |
| Certifications / Functional safety | Yes |
| Certifications / UL | cULus E225616 Power conversion equipment |
| B&R ID code | 0x2C22 |
| Cooling and mounting type | Wall mounting |
| Slots for plug-in modules | 2 |
DC bus connection
| Voltage / Nominal | 750 VDC |
| Power dissipation depending on switching frequency / Switching frequency 5 kHz | In preparation |
| Power dissipation depending on switching frequency / Switching frequency 10 kHz | In preparation |
| Power dissipation depending on switching frequency / Switching frequency 20 kHz | In preparation |
| Continuous power consumption | 48.8 kW |
| DC bus capacitance | 1980 µF |
| Variant | ACOPOSmulti backplane |
24 VDC power supply
| Input voltage | 25 VDC ±1.6% |
| Input capacitance | 32.9 µF |
| Max. power consumption | 27 W + PSLOT1 + PSLOT2 + P24 V Out + PHoldingBrake |
| Variant | ACOPOSmulti backplane |
24 VDC output
| Output voltage / DC bus voltage (UDC): 260 to 315 VDC | 25 VDC * (UDC/315) |
| Output voltage / DC bus voltage (UDC): 315 to 800 VDC | 24 VDC ±6% |
| Quantity | 2 |
| Fuse protection | 250 mA (slow-blow) electronic, automatic reset |
Motor connection
| Reduction of continuous current depending on switching frequency / Switching frequency 5 kHz | 1.4 A/K (starting at 41°C) |
| Reduction of continuous current depending on switching frequency / Switching frequency 10 kHz | 0.92 A/K (starting at -5°C) |
| Reduction of continuous current depending on switching frequency / Switching frequency 20 kHz | 0.56 A/K (starting at -90°C) |
| Reduction of continuous current depending on installation elevation / Starting at 500 m above sea level | 6.6 Aeff per 1000 m |
| Protective measures / Overload protection | Yes |
| Protective measures / Short-circuit and ground fault protection | Yes |
| Variant / U, V, W, PE | M8 threaded bolts |
| Variant / Shield connection | Yes |
| Connection cross section range / Flexible and fine-stranded wires | --- |
| Max. motor line length depending on switching frequency / Switching frequency 5 kHz | 25 m |
| Max. motor line length depending on switching frequency / Switching frequency 10 kHz | 25 m |
| Max. motor line length depending on switching frequency / Switching frequency 20 kHz | 25 m |
| Quantity | 1 |
| Continuous power per motor connection | 48 kW |
| Continuous current per motor connection | 66 Aeff |
| Peak current | 132 Aeff |
| Nominal switching frequency | 5 kHz |
| Possible switching frequencies | 5 / 10 / 20 kHz |
| Insulation stress of the connected motor per IEC TS 60034-25:2004 | Limit value curve A |
| Max. output frequency | 598 Hz |
| Terminal cable cross section dimension of shield connection | 12 to 50 mm |
Motor holding brake connection
| Protective measures / Overload and short-circuit protection | Yes |
| Protective measures / Open-circuit monitoring | Yes |
| Protective measures / Undervoltage monitoring | Yes |
| Quantity | 1 |
| Output voltage | 24 VDC +5.8% / -0% |
| Continuous current per connection | 4.2 A |
| Max. internal resistance | 0.15 Ω |
| Extinction potential | Approx. 30 V |
| Max. extinction energy per switching operation | 3 Ws |
| Max. switching frequency | 0.5 Hz |
| Response threshold for open-circuit monitoring | Approx. 0.5 A |
| Response threshold for undervoltage monitoring | 24 VDC +0% / -4% |
Enable inputs
| Electrical isolation / Input - Inverter module | Yes |
| Electrical isolation / Input - Input | Yes |
| Input voltage / Nominal | 24 VDC |
| Input voltage / Maximum | 30 VDC |
| Switching threshold / Low | <5 V |
| Switching threshold / High | >15 V |
| Switching delay at nominal input voltage / Enable 1 → 0, PWM off | Max. 20.5 ms |
| Switching delay at nominal input voltage / Enable 0 → 1, ready for PWM | Max. 100 µs |
| Quantity | 2 |
| Circuit | Sink |
| Input current at nominal voltage | Approx. 30 mA |
| Modulation compared to ground potential | Max. ±38 V |
| OSSD signal connections | Permitted Max. test pulse length: 500 µs |
Trigger inputs
| Electrical isolation / Input - Inverter module | Yes |
| Electrical isolation / Input - Input | Yes |
| Input voltage / Nominal | 24 VDC |
| Input voltage / Maximum | 30 VDC |
| Switching threshold / Low | <5 V |
| Switching threshold / High | >15 V |
| Switching delay / Rising edge | 52 µs ±0.5 µs (digitally filtered) |
| Switching delay / Falling edge | 53 µs ±0.5 µs (digitally filtered) |
| Quantity | 2 |
| Circuit | Sink |
| Input current at nominal voltage | Approx. 10 mA |
| Modulation compared to ground potential | Max. ±38 V |
Temperature sensor connection
| Quantity | 1 |
| Resistance range | 500 Ω to 5 kΩ |
Electrical properties
| Energy efficiency (IE classification) / Power dissipation relative to continuous apparent power | IE2 (10,25) 1% IE2 (50,25) 1% IE2 (10,50) 1.3% IE2 (50,50) 1.3% IE2 (90,50) 1.3% IE2 (10,100) 2% IE2 (50,100) 2.1% IE2 (90,100) 2.1% |
| Energy efficiency (IE classification) / Nominal losses in standby mode | 10.5 W |
| Discharge capacitance | 0.44 µF |
Operating conditions
| Permissible mounting orientations / Hanging vertically | Yes |
| Permissible mounting orientations / Horizontal, face up | Yes |
| Permissible mounting orientations / Standing horizontally | No |
| Installation elevation above sea level / Nominal | 0 to 500 m |
| Installation elevation above sea level / Maximum | 4000 m |
| Pollution degree per EN 61800-5-1 | 2 (non-conductive pollution) |
| Overvoltage category per EN 61800-5-1 | III |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature / Operation / Nominal | 5 to 40°C |
| Temperature / Operation / Maximum | 55°C |
| Temperature / Storage | -25 to 55°C |
| Temperature / Transport | -25 to 70°C |
| Relative humidity / Operation | 5 to 85% |
| Relative humidity / Storage | 5 to 95% |
| Relative humidity / Transport | Max. 95% at 40°C |
Mechanical properties
| Dimensions / Depth / Wall mounting | 263 mm |
| Dimensions / Width | 213.5 mm |
| Dimensions / Height | 317 mm |
| Weight | Approx. 10.85 kg |
| Module width | 4 |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
Manuals
3D CAD models
ECAD / EPLAN
Certificates
- E225616 UL Certificate of Compliance ACOPOSmulti (UL 61800-5-1)
- EU Declaration FS Servos ACOPOSmulti(en)
- EU Declaration FS Servos ACOPOSmulti
- EU Declaration Servos ACOPOSmulti
- TÜV-certificate - function "Safe Pulse Disabling" for ACOPOSmulti
- UK Declaration FS Servos ACOPOSmulti(en)
- UK Declaration FS Servos ACOPOSmulti
- UK Declaration Servos ACOPOSmulti
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.