IAC

B&R 8BVI0880HWS0.008-1

ACOPOSmulti inverter module, 88 A, AS, wall mounting

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

Replacing or upgrading a servo component?

Servo amplifiers, motors, encoders and cables are matched sets. If this part is no longer available in its original form, the manufacturer's newer generation usually will not pair with the rest of the axis, so an upgrade normally covers the drive, motor and cables together. Send us the nameplate details and we will confirm availability of an exact spare or scope a compatible upgrade.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

General information
Support / Dynamic node allocation (DNA)Yes
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)Evaluation ongoing
Certifications / Functional safetyYes
Certifications / ULcULus E225616 Power conversion equipment
B&R ID code0x2C1E
Cooling and mounting typeWall mounting
Slots for plug-in modules2
DC bus connection
Voltage / Nominal750 VDC
Power dissipation depending on switching frequency / Switching frequency 5 kHz1235 W
Power dissipation depending on switching frequency / Switching frequency 10 kHz2055 W
Power dissipation depending on switching frequency / Switching frequency 20 kHz3700 W
Continuous power consumption65 kW
DC bus capacitance1980 µF
VariantACOPOSmulti backplane
24 VDC power supply
Input voltage25 VDC ±1.6%
Input capacitance32.9 µF
Max. power consumption27 W + PSLOT1 + PSLOT2 + P24 V Out + PHoldingBrake
VariantACOPOSmulti backplane
24 VDC output
Output voltage / DC bus voltage (UDC): 260 to 315 VDC25 VDC * (UDC/315)
Output voltage / DC bus voltage (UDC): 315 to 800 VDC24 VDC ±6%
Quantity2
Fuse protection250 mA (slow-blow) electronic, automatic reset
Motor connection
Reduction of continuous current depending on switching frequency / Switching frequency 5 kHz1.4 A/K (starting at 41°C)
Reduction of continuous current depending on switching frequency / Switching frequency 10 kHz0.92 A/K (starting at -5°C)
Reduction of continuous current depending on switching frequency / Switching frequency 20 kHz0.56 A/K (starting at -90°C)
Reduction of continuous current depending on installation elevation / Starting at 500 m above sea level8.8 Aeff per 1000 m
Protective measures / Overload protectionYes
Protective measures / Short-circuit and ground fault protectionYes
Variant / U, V, W, PEM8 threaded bolts
Variant / Shield connectionYes
Connection cross section range / Flexible and fine-stranded wires---
Max. motor line length depending on switching frequency / Switching frequency 5 kHz25 m
Max. motor line length depending on switching frequency / Switching frequency 10 kHz25 m
Max. motor line length depending on switching frequency / Switching frequency 20 kHz25 m
Quantity1
Continuous power per motor connection64 kW
Continuous current per motor connection88 Aeff
Peak current176 Aeff
Nominal switching frequency5 kHz
Possible switching frequencies5 / 10 / 20 kHz
Insulation stress of the connected motor per IEC TS 60034-25:2004Limit value curve A
Max. output frequency598 Hz
Terminal cable cross section dimension of shield connection12 to 50 mm
Motor holding brake connection
Protective measures / Overload and short-circuit protectionYes
Protective measures / Open-circuit monitoringYes
Protective measures / Undervoltage monitoringYes
Quantity1
Output voltage24 VDC +5.8% / -0%
Continuous current per connection4.2 A
Max. internal resistance0.15 Ω
Extinction potentialApprox. 30 V
Max. extinction energy per switching operation3 Ws
Max. switching frequency0.5 Hz
Response threshold for open-circuit monitoringApprox. 0.5 A
Response threshold for undervoltage monitoring24 VDC +0% / -4%
Enable inputs
Electrical isolation / Input - Inverter moduleYes
Electrical isolation / Input - InputYes
Input voltage / Nominal24 VDC
Input voltage / Maximum30 VDC
Switching threshold / Low<5 V
Switching threshold / High>15 V
Switching delay at nominal input voltage / Enable 1 → 0, PWM offMax. 20.5 ms
Switching delay at nominal input voltage / Enable 0 → 1, ready for PWMMax. 100 µs
Quantity2
CircuitSink
Input current at nominal voltageApprox. 30 mA
Modulation compared to ground potentialMax. ±38 V
OSSD signal connectionsPermitted Max. test pulse length: 500 µs
Trigger inputs
Electrical isolation / Input - Inverter moduleYes
Electrical isolation / Input - InputYes
Input voltage / Nominal24 VDC
Input voltage / Maximum30 VDC
Switching threshold / Low<5 V
Switching threshold / High>15 V
Switching delay / Rising edge52 µs ±0.5 µs (digitally filtered)
Switching delay / Falling edge53 µs ±0.5 µs (digitally filtered)
Quantity2
CircuitSink
Input current at nominal voltageApprox. 10 mA
Modulation compared to ground potentialMax. ±38 V
Temperature sensor connection
Quantity1
Resistance range500 Ω to 5 kΩ
Electrical properties
Energy efficiency (IE classification) / Power dissipation relative to continuous apparent powerIE2 (10,25) 0.9% IE2 (50,25) 0.9% IE2 (10,50) 1.1% IE2 (50,50) 1.1% IE2 (90,50) 1.1% IE2 (10,100) 1.9% IE2 (50,100) 1.9% IE2 (90,100) 1.9%
Energy efficiency (IE classification) / Nominal losses in standby mode10.5 W
Discharge capacitance0.44 µF
Operating conditions
Permissible mounting orientations / Hanging verticallyYes
Permissible mounting orientations / Horizontal, face upYes
Permissible mounting orientations / Standing horizontallyNo
Installation elevation above sea level / Nominal0 to 500 m
Installation elevation above sea level / Maximum4000 m
Pollution degree per EN 61800-5-12 (non-conductive pollution)
Overvoltage category per EN 61800-5-1III
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Nominal5 to 40°C
Temperature / Operation / Maximum55°C
Temperature / Storage-25 to 55°C
Temperature / Transport-25 to 70°C
Relative humidity / Operation5 to 85%
Relative humidity / Storage5 to 95%
Relative humidity / TransportMax. 95% at 40°C
Mechanical properties
Dimensions / Depth / Wall mounting263 mm
Dimensions / Width213.5 mm
Dimensions / Height317 mm
WeightApprox. 10.9 kg
Module width4

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.