IAC

B&R 8BVP0880HC00.008-3

ACOPOSmulti3 power supply module, 88 A, AS, cold plate or pass-through mounting, optimized for applications with decentralized, computationally intensive open-loop and closed-loop control requirements

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

Replacing or upgrading a servo component?

Servo amplifiers, motors, encoders and cables are matched sets. If this part is no longer available in its original form, the manufacturer's newer generation usually will not pair with the rest of the axis, so an upgrade normally covers the drive, motor and cables together. Send us the nameplate details and we will confirm availability of an exact spare or scope a compatible upgrade.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

General information
System requirements / Automation Studio4.6.1.x or later
Support / Dynamic node allocation (DNA)Yes
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / ULcULus E225616 Power conversion equipment
Certifications / KCYes
B&R ID code0x2EE7
Cooling and mounting typeCold plate or pass-through mounting
Slots for plug-in modules2
Mains connection
Max. chargeable DC bus capacitance depending on mains voltage / 230 VAC34.8 mF
Max. chargeable DC bus capacitance depending on mains voltage / 400 VAC11.5 mF
Max. chargeable DC bus capacitance depending on mains voltage / 480 VAC8 mF
Variant / L1, L2, L3, PEM8 threaded bolts
Variant / Shield connectionYes
Connection cross section range / Flexible and fine-stranded wires---
Network configurationsTT, TN-S, TN-C-S
Mains input voltage3x 220 to 3x 480 VAC ±10%
Frequency50 / 60 Hz ±4%
Total harmonic distortion current (THDi)<0.2%
Total harmonic distortion voltage (THDu)<1%
Installed loadMax. 62 kW
Inrush current at 400 VACMax. 133 A
Switch-on interval>300 s
Nominal switching frequency5 kHz
Possible switching frequencies5 / 10 kHz
Integrated line filter per EN 61800-3, category C3No
Integrated regeneration chokeNo
RegenerativeYes
Power factor correction (PFC)Yes
Line fuseMax. 264 A (gG fuses per IEC 60269-1 or Class CC, J, T) Max. 220 A (circuit breaker per EN 60947-2 or UL 489)
Terminal cable cross section dimension of shield connection32 to 50 mm
DC bus connection
Voltage / Nominal750 VDC
Reduction of continuous power depending on mains input voltage / Mains input voltage <3x 400 VAC150 W/V * (400 V - Mains input voltage)
Reduction of continuous power depending on DC bus voltage (UDC) / UDC <750 VDC0.08 kW/V
Reduction of continuous power depending on switching frequency and mounting type / Switching frequency 5 kHz / Cold plate mounting1.3 kW/K (starting at 58°C)
Reduction of continuous power depending on switching frequency and mounting type / Switching frequency 5 kHz / Pass-through mountingIn preparation
Reduction of continuous power depending on switching frequency and mounting type / Switching frequency 10 kHz / Cold plate mounting0.95 kW/K (starting at 27°C)
Reduction of continuous power depending on switching frequency and mounting type / Switching frequency 10 kHz / Pass-through mountingIn preparation
Reduction of continuous power depending on installation elevation / Starting at 500 m above sea level6 kW per 1000 m
Reduction of peak power depending on mains input voltage / Mains input voltage <3x 400 VAC300 W/V * (400 V - Mains input voltage)
Power dissipation depending on switching frequency / Switching frequency 5 kHzIn preparation
Power dissipation depending on switching frequency / Switching frequency 10 kHzIn preparation
Protective measures / Overload protectionYes
Protective measures / Short-circuit and ground fault protectionNo
Continuous power (supply and regeneration)60 kW
Peak power (supply and regeneration)120 kW
DC bus capacitance1650 µF
VariantACOPOSmulti backplane
24 VDC power supply
Input voltage25 VDC ±1.6%
Input capacitance4.7 µF
Max. power consumption27 W + PSLOT1 + PSLOT2 + P24 V Out + PFan8BVF...
VariantACOPOSmulti backplane
24 VDC Out
Output voltage / DC bus voltage (UDC): 260 to 315 VDC25 VDC * (UDC / 315)
Output voltage / DC bus voltage (UDC): 315 to 800 VDC24 VDC ±6%
Quantity2
Fuse protection250 mA (slow-blow) electronic, automatic reset
Filter fan connection
Protective measures / Overload protectionNo
Protective measures / Short-circuit proofYes
Protective measures / Open-circuit monitoringNo
Protective measures / Undervoltage monitoringNo
Output voltage24 V +5.8% / -0.1%
Continuous current4.2 A
Max. overcurrent limiting10 A
Trigger inputs
Electrical isolation / Input - Power supply moduleYes
Electrical isolation / Input - InputYes
Input voltage / Nominal24 VDC
Input voltage / Maximum30 VDC
Switching threshold / Low<5 V
Switching threshold / High>15 V
Switching delay / Rising edge52 μs ±0.5 μs (digitally filtered)
Switching delay / Falling edge53 μs ±0.5 μs (digitally filtered)
Quantity2
CircuitSink
Input current at nominal voltageApprox. 10 mA
Modulation compared to ground potentialMax. ±38 V
Support
Motion system / mapp Motion5.24.1 and higher
Motion system / ACP10/ARNC05.24.1 and higher
Electrical properties
Energy efficiency (IE classification) / Power dissipation relative to continuous apparent powerIE2 (10,25) 0.3% IE2 (50,25) 0.3% IE2 (10,50) 0.3% IE2 (50,50) 0.6% IE2 (90,50) 1.1% IE2 (10,100) 0.3% IE2 (50,100) 1.1% IE2 (90,100) 2.3%
Energy efficiency (IE classification) / Nominal losses in standby mode11.8 W
Discharge capacitance0.9 µF
Operating conditions
Permissible mounting orientations / Hanging verticallyYes
Permissible mounting orientations / Horizontal, face upYes
Permissible mounting orientations / Standing horizontallyNo
Installation elevation above sea level / Nominal0 to 500 m
Installation elevation above sea level / Maximum4000 m
Pollution degree per EN 61800-5-12 (non-conductive pollution)
Overvoltage category per EN 61800-5-1III
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Nominal5 to 40°C
Temperature / Operation / Maximum55°C
Temperature / Storage-25 to 55°C
Temperature / Transport-25 to 70°C
Relative humidity / Operation5 to 85%
Relative humidity / Storage5 to 95%
Relative humidity / TransportMax. 95% at 40°C
Mechanical properties
Dimensions / Depth / Cold plate212 mm
Dimensions / Depth / Pass-through mounting209 mm
Dimensions / Width213.5 mm
Dimensions / Height317 mm
WeightApprox. 8.4 kg
Module width4

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.