B&R 8BVP0880HC00.008-3
ACOPOSmulti3 power supply module, 88 A, AS, cold plate or pass-through mounting, optimized for applications with decentralized, computationally intensive open-loop and closed-loop control requirements
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
Servo amplifiers, motors, encoders and cables are matched sets. If this part is no longer available in its original form, the manufacturer's newer generation usually will not pair with the rest of the axis, so an upgrade normally covers the drive, motor and cables together. Send us the nameplate details and we will confirm availability of an exact spare or scope a compatible upgrade.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
General information
| System requirements / Automation Studio | 4.6.1.x or later |
| Support / Dynamic node allocation (DNA) | Yes |
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | In preparation |
| Certifications / UL | cULus E225616 Power conversion equipment |
| Certifications / KC | Yes |
| B&R ID code | 0x2EE7 |
| Cooling and mounting type | Cold plate or pass-through mounting |
| Slots for plug-in modules | 2 |
Mains connection
| Max. chargeable DC bus capacitance depending on mains voltage / 230 VAC | 34.8 mF |
| Max. chargeable DC bus capacitance depending on mains voltage / 400 VAC | 11.5 mF |
| Max. chargeable DC bus capacitance depending on mains voltage / 480 VAC | 8 mF |
| Variant / L1, L2, L3, PE | M8 threaded bolts |
| Variant / Shield connection | Yes |
| Connection cross section range / Flexible and fine-stranded wires | --- |
| Network configurations | TT, TN-S, TN-C-S |
| Mains input voltage | 3x 220 to 3x 480 VAC ±10% |
| Frequency | 50 / 60 Hz ±4% |
| Total harmonic distortion current (THDi) | <0.2% |
| Total harmonic distortion voltage (THDu) | <1% |
| Installed load | Max. 62 kW |
| Inrush current at 400 VAC | Max. 133 A |
| Switch-on interval | >300 s |
| Nominal switching frequency | 5 kHz |
| Possible switching frequencies | 5 / 10 kHz |
| Integrated line filter per EN 61800-3, category C3 | No |
| Integrated regeneration choke | No |
| Regenerative | Yes |
| Power factor correction (PFC) | Yes |
| Line fuse | Max. 264 A (gG fuses per IEC 60269-1 or Class CC, J, T) Max. 220 A (circuit breaker per EN 60947-2 or UL 489) |
| Terminal cable cross section dimension of shield connection | 32 to 50 mm |
DC bus connection
| Voltage / Nominal | 750 VDC |
| Reduction of continuous power depending on mains input voltage / Mains input voltage <3x 400 VAC | 150 W/V * (400 V - Mains input voltage) |
| Reduction of continuous power depending on DC bus voltage (UDC) / UDC <750 VDC | 0.08 kW/V |
| Reduction of continuous power depending on switching frequency and mounting type / Switching frequency 5 kHz / Cold plate mounting | 1.3 kW/K (starting at 58°C) |
| Reduction of continuous power depending on switching frequency and mounting type / Switching frequency 5 kHz / Pass-through mounting | In preparation |
| Reduction of continuous power depending on switching frequency and mounting type / Switching frequency 10 kHz / Cold plate mounting | 0.95 kW/K (starting at 27°C) |
| Reduction of continuous power depending on switching frequency and mounting type / Switching frequency 10 kHz / Pass-through mounting | In preparation |
| Reduction of continuous power depending on installation elevation / Starting at 500 m above sea level | 6 kW per 1000 m |
| Reduction of peak power depending on mains input voltage / Mains input voltage <3x 400 VAC | 300 W/V * (400 V - Mains input voltage) |
| Power dissipation depending on switching frequency / Switching frequency 5 kHz | In preparation |
| Power dissipation depending on switching frequency / Switching frequency 10 kHz | In preparation |
| Protective measures / Overload protection | Yes |
| Protective measures / Short-circuit and ground fault protection | No |
| Continuous power (supply and regeneration) | 60 kW |
| Peak power (supply and regeneration) | 120 kW |
| DC bus capacitance | 1650 µF |
| Variant | ACOPOSmulti backplane |
24 VDC power supply
| Input voltage | 25 VDC ±1.6% |
| Input capacitance | 4.7 µF |
| Max. power consumption | 27 W + PSLOT1 + PSLOT2 + P24 V Out + PFan8BVF... |
| Variant | ACOPOSmulti backplane |
24 VDC Out
| Output voltage / DC bus voltage (UDC): 260 to 315 VDC | 25 VDC * (UDC / 315) |
| Output voltage / DC bus voltage (UDC): 315 to 800 VDC | 24 VDC ±6% |
| Quantity | 2 |
| Fuse protection | 250 mA (slow-blow) electronic, automatic reset |
Filter fan connection
| Protective measures / Overload protection | No |
| Protective measures / Short-circuit proof | Yes |
| Protective measures / Open-circuit monitoring | No |
| Protective measures / Undervoltage monitoring | No |
| Output voltage | 24 V +5.8% / -0.1% |
| Continuous current | 4.2 A |
| Max. overcurrent limiting | 10 A |
Trigger inputs
| Electrical isolation / Input - Power supply module | Yes |
| Electrical isolation / Input - Input | Yes |
| Input voltage / Nominal | 24 VDC |
| Input voltage / Maximum | 30 VDC |
| Switching threshold / Low | <5 V |
| Switching threshold / High | >15 V |
| Switching delay / Rising edge | 52 μs ±0.5 μs (digitally filtered) |
| Switching delay / Falling edge | 53 μs ±0.5 μs (digitally filtered) |
| Quantity | 2 |
| Circuit | Sink |
| Input current at nominal voltage | Approx. 10 mA |
| Modulation compared to ground potential | Max. ±38 V |
Support
| Motion system / mapp Motion | 5.24.1 and higher |
| Motion system / ACP10/ARNC0 | 5.24.1 and higher |
Electrical properties
| Energy efficiency (IE classification) / Power dissipation relative to continuous apparent power | IE2 (10,25) 0.3% IE2 (50,25) 0.3% IE2 (10,50) 0.3% IE2 (50,50) 0.6% IE2 (90,50) 1.1% IE2 (10,100) 0.3% IE2 (50,100) 1.1% IE2 (90,100) 2.3% |
| Energy efficiency (IE classification) / Nominal losses in standby mode | 11.8 W |
| Discharge capacitance | 0.9 µF |
Operating conditions
| Permissible mounting orientations / Hanging vertically | Yes |
| Permissible mounting orientations / Horizontal, face up | Yes |
| Permissible mounting orientations / Standing horizontally | No |
| Installation elevation above sea level / Nominal | 0 to 500 m |
| Installation elevation above sea level / Maximum | 4000 m |
| Pollution degree per EN 61800-5-1 | 2 (non-conductive pollution) |
| Overvoltage category per EN 61800-5-1 | III |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature / Operation / Nominal | 5 to 40°C |
| Temperature / Operation / Maximum | 55°C |
| Temperature / Storage | -25 to 55°C |
| Temperature / Transport | -25 to 70°C |
| Relative humidity / Operation | 5 to 85% |
| Relative humidity / Storage | 5 to 95% |
| Relative humidity / Transport | Max. 95% at 40°C |
Mechanical properties
| Dimensions / Depth / Cold plate | 212 mm |
| Dimensions / Depth / Pass-through mounting | 209 mm |
| Dimensions / Width | 213.5 mm |
| Dimensions / Height | 317 mm |
| Weight | Approx. 8.4 kg |
| Module width | 4 |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
3D CAD models
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.