B&R 8CCH0003.11110-0
Optimally suited for use with ACOPOSremote/ACOPOSmotor drive systems Hybrid connector system for secure connections Hybrid cable, length 3 m, 2x 2x 0.34 mm² + 4x 0.75 mm² + 5x 2.5 mm², 2x 15-pin female TYCO connector
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
General information
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / UL | cULus E225616 Power conversion equipment |
| Cable cross section | 5x 2.5 mm² + 4x 0.75 mm² + 2x 2x 0.34 mm² / 1.55- 100 LI |
| Durability | In preparation |
| Certification | UL AWM style 20234, 80°C, 1000 V and CSA C22.2 no. 210.2 I/II A/B, FT1 |
Cable construction
| Power lines / Quantity | 5 |
| Power lines / Wire insulation | Special thermoplastic material |
| Power lines / Wire colors | Black, red, green, white, yellow/green |
| Power lines / Variant | Tinned copper stranded wire |
| Power lines / Cross section | 2.5 mm² |
| Power lines / Shield | No |
| Power lines / Stranding | No |
| Signal line / Quantity | 4 |
| Signal line / Wire insulation | Special thermoplastic material |
| Signal line / Wire colors | Pink, blue, violet, gray |
| Signal line / Variant | Tinned copper stranded wire |
| Signal line / Cross section | 0.75 mm² |
| Signal line / Shield | Yes |
| Signal line / Stranding | Yes |
| Data lines / Quantity | 4 |
| Data lines / Wire insulation | Special thermoplastic material |
| Data lines / Wire colors | Orange, white, yellow, blue |
| Data lines / Variant | Tinned copper stranded wire |
| Data lines / Cross section | 0.34 mm² |
| Data lines / Shield | Yes |
| Data lines / Stranding | Yes |
| Outer jacket / Material | PUR |
| Outer jacket / Color | Orange, similar to RAL 2003 flat |
| Outer jacket / Labeling | In preparation |
| Cable stranding | With filler elements and foil shield |
| Cable shield | Tinned copper braiding, optical coverage >85% and foil shield |
Connector
| Type | 15-pin female TYCO connector |
| Mating cycles | Max. 20 |
| Contacts | 15 |
| Degree of protection per EN 60529 | IP65 |
Electrical properties
| Test voltage / Wire - Wire | 3 kV AC |
| Test voltage / Wire - Shield | 3 kV AC |
| Conductor resistance / Power lines | ≤0.02 Ω |
| Conductor resistance / Signal line | ≤0.08 Ω |
| Conductor resistance / Data lines | ≤0.17 Ω |
| Operating voltage | Power lines: ≤1000 V Signal lines: ≤1000 V Data lines: ≤100 V |
| Current-carrying capacity | 20 A |
| Insulation resistance | >166.67 GΩ |
Ambient conditions
| Temperature / Moving | -40 to 80°C |
| Temperature / Static | -40 to 80°C |
Mechanical properties
| Dimensions / Length | 3 m |
| Dimensions / Diameter | 14.6 mm ±0.4 mm |
| Bend radius / Single bend | >40 mm |
| Bend radius / Moving | ≥140 mm |
| Drag chain data / Acceleration | <4 m/s² |
| Drag chain data / Flex cycles | ≥5,000,000 |
| Drag chain data / Velocity | ≤4 m/s |
| Weight | 1.55 kg |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
3D CAD models
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.