IAC

B&R 8CM100.30-0

Motor cable, length 100 m, 4 x 0.75 mm² + 2 x 2 x 0.34 mm², not pre-assembled, UL/CSA listed

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

General information
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)Not applicable
Certifications / ULcULus E225616 Power conversion equipment
Cable cross section4x 0.75 mm² + 2x 2x 0.35 mm²
DurabilityOil resistance per VDE 0472 Part 803 as well as standard hydraulic oils
CertificationUL AWM style 20234, 80°C, 1000 V, E63216 and CSA AWM I/II A/B, 90°C, 1000 V, FT2 LL46064
Cable construction
Power lines / Quantity4
Power lines / Wire insulationSpecial thermoplastic material
Power lines / Wire colorsBlack, brown, blue, yellow/green
Power lines / VariantTinned copper stranded wire
Power lines / Cross section0.75 mm²
Power lines / ShieldNo
Power lines / StrandingNo
Signal line / Quantity4
Signal line / Wire insulationSpecial thermoplastic material
Signal line / Wire colorsWhite, white/red, white/blue, white/green
Signal line / VariantTinned copper stranded wire
Signal line / Cross section0.35 mm²
Signal line / ShieldIndividually shielded in pairs, tinned copper braiding, optical coverage >85% and foil shield
Signal line / StrandingWhite with white/red and white/blue with white/green
Outer jacket / MaterialPUR
Outer jacket / ColorOrange, similar to RAL 2003 flat
Outer jacket / LabelingBERNECKER + RAINER 4x0,75+2x2x0,35 FLEX UL AWM STYLE 20234 80°C 1000 V E63216 CSA AWM I/II A/B 90°C 1000 V FT2 LL46064
Cable strandingWith filler elements and foil shield
Cable shieldTinned copper braiding, optical coverage >85% and foil shield
Electrical properties
Test voltage / Wire - Wire3 kV
Test voltage / Wire - Shield3 kV
Conductor resistance / Power lines≤0.15 Ω
Conductor resistance / Signal line≤0.28 Ω
Current-carrying capacity per DIN VDE 0298 part 4, table 11 / Wall mounting13 A
Current-carrying capacity per DIN VDE 0298 part 4, table 11 / Installed in conduit or cable duct11.5 A
Current-carrying capacity per DIN VDE 0298 part 4, table 11 / Installed in cable tray13.5 A
Insulation resistance>40 GΩ
Ambient conditions
Temperature / Moving-10 to 80°C
Temperature / Static-40 to 90°C
Mechanical properties
Dimensions / Length100 m
Dimensions / Diameter10.9 mm ±0.4 mm
Bend radius / Single bend>34 mm
Bend radius / Moving≥85 mm
Weight17.6 kg

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.