IAC

B&R 8CVE28000HC00.00-1

Remote power distribution up to 30 kW using up to four hybrid cable outlets Safeguards the DC bus Diagnostics for all connections Integrated connections for local I/O nodes ACOPOSremote/ACOPOSmotor connection box, AS, IP65, cold plate mounting, 4x connection for hybrid cable, 2x 24 VDC Out

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

Replacing or upgrading a servo component?

Servo amplifiers, motors, encoders and cables are matched sets. If this part is no longer available in its original form, the manufacturer's newer generation usually will not pair with the rest of the axis, so an upgrade normally covers the drive, motor and cables together. Send us the nameplate details and we will confirm availability of an exact spare or scope a compatible upgrade.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

General information
Support / Dynamic node allocation (DNA)Yes
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)Not applicable
Certifications / Functional safetyYes
Certifications / ULcULus E225616 Power conversion equipment
B&R ID code0xB41D
Status indicatorsSafety status, interface status
Cooling and mounting typeCold plate mounting
DC bus connection
Voltage / Nominal750 VDC
Execution / DC+, DC-, PECage clamp terminal block
Execution / Shield connectionYes (via cable gland)
Terminal connection cross sections / Flexible and fine-stranded wires / With wire end sleeves0.25 to 10 mm²
Terminal connection cross sections / Approbation data / UL/C-UL-US24 to 8
Terminal connection cross sections / Approbation data / CSA24 to 8
Terminal cross sections (cable diameter)14 to 21 mm (M32 cable grommet)
Max. line length30 m
24 VDC power supply
Execution / 24 VDC, COM, PECage clamp terminal block
Execution / Shield connectionNo
Terminal connection cross sections / Flexible and fine-stranded wires / With wire end sleeves0.25 to 10 mm²
Terminal connection cross sections / Approbation data / UL/C-UL-US24 to 8
Terminal connection cross sections / Approbation data / CSA24 to 8
Quantity2
Input voltage24 VDC -25% / +20%
Max. power consumptionIn preparation
Terminal cross sections (cable diameter)14 to 21 mm (M32 cable grommet)
Max. line length30 m
Hybrid cable outlets
DC+ and DC- fuse protection / Rated current of fuse depending on ambient temperature / 40°CIn preparation
DC+ and DC- fuse protection / Rated current of fuse depending on ambient temperature / 60°C20 A
DC+ and DC- fuse protection / TypeMelting fuse conforming to UL/CSA, ø 10 x 38 mm
DC+ and DC- fuse protection / Tripping characteristicFast-acting
24 VDC fuse protection / Rated current of fuse depending on ambient temperature / 40°CIn preparation
24 VDC fuse protection / Rated current of fuse depending on ambient temperature / 60°C15 A
24 VDC fuse protection / TypeBlade fuses conforming to UL/CSA
24 VDC fuse protection / Tripping characteristicFast-acting
Continuous power depending on rated current of fuse / DC+ and DC- / 20 A10.1 kW
Continuous power depending on rated current of fuse / 24 VDC / 15 A240 W
Continuous current depending on rated current of fuse / DC+ and DC- / 20 A13.5 Aeff
Continuous current depending on rated current of fuse / 24 VDC / 15 A10.1 A
Reduction of continuous power depending on installation elevation / Starting at 500 m above sea level10% per 1,000 m
Power dissipation with continuous power / DC+ and DC- / 20 AIn preparation
Power dissipation with continuous power / 24 VDC / 15 AIn preparation
Protective measures / Overload protection / DC+ and DC-No (overload status can be retrieved via fieldbus)
Protective measures / Overload protection / 24 VDCNo (overload status can be retrieved via fieldbus)
Protective measures / Short-circuit and ground fault protection / DC+ and DC-Yes
Protective measures / Short-circuit and ground fault protection / 24 VDCYes
Quantity4 (each with DC bus, 24 VDC, 2x enable, POWERLINK)
Continuous current of enable outputsMax. 500 mA
Max. line length30 m
Execution15-pin male TYCO connector
24 VDC output
Fuse protection per pin / Rated current of fuse depending on ambient temperature / 40°C5 A
Fuse protection per pin / Rated current of fuse depending on ambient temperature / 60°C7.5 A
Fuse protection per pin / TypeBlade fuses conforming to UL/CSA
Fuse protection per pin / Tripping characteristicFast-acting
Protective measures / Overload-proofNo (overload status can be retrieved via fieldbus)
Protective measures / Short-circuit proofYes
Execution / 24 VDC, COMFemale M8 connector
Quantity2
Output voltageDepends on the 24 VDC power supply
Continuous currentMax. 8 A (max. 4 A per pin)
Fieldbus
TypePOWERLINK (V1/V2) 100BASE-T (ANSI/IEE 802.3)
Execution1x internal 4-port hub, 1x internal 5-port hub; 4x 19-pin hybrid connector, 4x M12 female connector
Line lengthMax. 100 m between two stations (segment length)
Transfer rate100 Mbit/s
Enable inputs
Input voltage / Nominal24 VDC
Input voltage / Maximum30 VDC
Terminal connection cross sections / Flexible and fine-stranded wires / With plastic wire end sleeves0.25 to 1.5 mm²
Terminal connection cross sections / Approbation data / UL/C-UL-US26 to 12
Terminal connection cross sections / Approbation data / CSA-
Quantity2
Permissible input currentMax. 2 A
ExecutionCage clamp terminal block
Terminal cross sections (cable diameter)5 to 9 mm (M16 cable grommet)
Max. line length30 m
Operating conditions
Permissible mounting orientations / Hanging verticallyYes
Permissible mounting orientations / Horizontal, face upYes
Permissible mounting orientations / Standing horizontallyYes
Installation elevation above sea level / Nominal0 to 500 m
Installation elevation above sea level / Maximum4000 m
Pollution degree per EN 61800-5-12 (non-conductive pollution)
Overvoltage category per EN 61800-5-1III
Degree of protection per EN 60529IP65
Ambient conditions
Temperature / Operation / Nominal5 to 40°C
Temperature / Operation / Maximum60°C
Temperature / Storage-25 to 55°C
Temperature / Transport-25 to 70°C
Relative humidity / Operation5 to 85%, non-condensing
Relative humidity / Storage5 to 95%, non-condensing
Relative humidity / TransportMax. 95% at 40°C
Mechanical properties
Dimensions / Width293 mm
Dimensions / Height328 mm
Dimensions / Depth80 mm
Weight7 kg

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.