B&R 8CVE28000HC00.00-1
Remote power distribution up to 30 kW using up to four hybrid cable outlets Safeguards the DC bus Diagnostics for all connections Integrated connections for local I/O nodes ACOPOSremote/ACOPOSmotor connection box, AS, IP65, cold plate mounting, 4x connection for hybrid cable, 2x 24 VDC Out
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
Servo amplifiers, motors, encoders and cables are matched sets. If this part is no longer available in its original form, the manufacturer's newer generation usually will not pair with the rest of the axis, so an upgrade normally covers the drive, motor and cables together. Send us the nameplate details and we will confirm availability of an exact spare or scope a compatible upgrade.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
General information
| Support / Dynamic node allocation (DNA) | Yes |
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | Not applicable |
| Certifications / Functional safety | Yes |
| Certifications / UL | cULus E225616 Power conversion equipment |
| B&R ID code | 0xB41D |
| Status indicators | Safety status, interface status |
| Cooling and mounting type | Cold plate mounting |
DC bus connection
| Voltage / Nominal | 750 VDC |
| Execution / DC+, DC-, PE | Cage clamp terminal block |
| Execution / Shield connection | Yes (via cable gland) |
| Terminal connection cross sections / Flexible and fine-stranded wires / With wire end sleeves | 0.25 to 10 mm² |
| Terminal connection cross sections / Approbation data / UL/C-UL-US | 24 to 8 |
| Terminal connection cross sections / Approbation data / CSA | 24 to 8 |
| Terminal cross sections (cable diameter) | 14 to 21 mm (M32 cable grommet) |
| Max. line length | 30 m |
24 VDC power supply
| Execution / 24 VDC, COM, PE | Cage clamp terminal block |
| Execution / Shield connection | No |
| Terminal connection cross sections / Flexible and fine-stranded wires / With wire end sleeves | 0.25 to 10 mm² |
| Terminal connection cross sections / Approbation data / UL/C-UL-US | 24 to 8 |
| Terminal connection cross sections / Approbation data / CSA | 24 to 8 |
| Quantity | 2 |
| Input voltage | 24 VDC -25% / +20% |
| Max. power consumption | In preparation |
| Terminal cross sections (cable diameter) | 14 to 21 mm (M32 cable grommet) |
| Max. line length | 30 m |
Hybrid cable outlets
| DC+ and DC- fuse protection / Rated current of fuse depending on ambient temperature / 40°C | In preparation |
| DC+ and DC- fuse protection / Rated current of fuse depending on ambient temperature / 60°C | 20 A |
| DC+ and DC- fuse protection / Type | Melting fuse conforming to UL/CSA, ø 10 x 38 mm |
| DC+ and DC- fuse protection / Tripping characteristic | Fast-acting |
| 24 VDC fuse protection / Rated current of fuse depending on ambient temperature / 40°C | In preparation |
| 24 VDC fuse protection / Rated current of fuse depending on ambient temperature / 60°C | 15 A |
| 24 VDC fuse protection / Type | Blade fuses conforming to UL/CSA |
| 24 VDC fuse protection / Tripping characteristic | Fast-acting |
| Continuous power depending on rated current of fuse / DC+ and DC- / 20 A | 10.1 kW |
| Continuous power depending on rated current of fuse / 24 VDC / 15 A | 240 W |
| Continuous current depending on rated current of fuse / DC+ and DC- / 20 A | 13.5 Aeff |
| Continuous current depending on rated current of fuse / 24 VDC / 15 A | 10.1 A |
| Reduction of continuous power depending on installation elevation / Starting at 500 m above sea level | 10% per 1,000 m |
| Power dissipation with continuous power / DC+ and DC- / 20 A | In preparation |
| Power dissipation with continuous power / 24 VDC / 15 A | In preparation |
| Protective measures / Overload protection / DC+ and DC- | No (overload status can be retrieved via fieldbus) |
| Protective measures / Overload protection / 24 VDC | No (overload status can be retrieved via fieldbus) |
| Protective measures / Short-circuit and ground fault protection / DC+ and DC- | Yes |
| Protective measures / Short-circuit and ground fault protection / 24 VDC | Yes |
| Quantity | 4 (each with DC bus, 24 VDC, 2x enable, POWERLINK) |
| Continuous current of enable outputs | Max. 500 mA |
| Max. line length | 30 m |
| Execution | 15-pin male TYCO connector |
24 VDC output
| Fuse protection per pin / Rated current of fuse depending on ambient temperature / 40°C | 5 A |
| Fuse protection per pin / Rated current of fuse depending on ambient temperature / 60°C | 7.5 A |
| Fuse protection per pin / Type | Blade fuses conforming to UL/CSA |
| Fuse protection per pin / Tripping characteristic | Fast-acting |
| Protective measures / Overload-proof | No (overload status can be retrieved via fieldbus) |
| Protective measures / Short-circuit proof | Yes |
| Execution / 24 VDC, COM | Female M8 connector |
| Quantity | 2 |
| Output voltage | Depends on the 24 VDC power supply |
| Continuous current | Max. 8 A (max. 4 A per pin) |
Fieldbus
| Type | POWERLINK (V1/V2) 100BASE-T (ANSI/IEE 802.3) |
| Execution | 1x internal 4-port hub, 1x internal 5-port hub; 4x 19-pin hybrid connector, 4x M12 female connector |
| Line length | Max. 100 m between two stations (segment length) |
| Transfer rate | 100 Mbit/s |
Enable inputs
| Input voltage / Nominal | 24 VDC |
| Input voltage / Maximum | 30 VDC |
| Terminal connection cross sections / Flexible and fine-stranded wires / With plastic wire end sleeves | 0.25 to 1.5 mm² |
| Terminal connection cross sections / Approbation data / UL/C-UL-US | 26 to 12 |
| Terminal connection cross sections / Approbation data / CSA | - |
| Quantity | 2 |
| Permissible input current | Max. 2 A |
| Execution | Cage clamp terminal block |
| Terminal cross sections (cable diameter) | 5 to 9 mm (M16 cable grommet) |
| Max. line length | 30 m |
Operating conditions
| Permissible mounting orientations / Hanging vertically | Yes |
| Permissible mounting orientations / Horizontal, face up | Yes |
| Permissible mounting orientations / Standing horizontally | Yes |
| Installation elevation above sea level / Nominal | 0 to 500 m |
| Installation elevation above sea level / Maximum | 4000 m |
| Pollution degree per EN 61800-5-1 | 2 (non-conductive pollution) |
| Overvoltage category per EN 61800-5-1 | III |
| Degree of protection per EN 60529 | IP65 |
Ambient conditions
| Temperature / Operation / Nominal | 5 to 40°C |
| Temperature / Operation / Maximum | 60°C |
| Temperature / Storage | -25 to 55°C |
| Temperature / Transport | -25 to 70°C |
| Relative humidity / Operation | 5 to 85%, non-condensing |
| Relative humidity / Storage | 5 to 95%, non-condensing |
| Relative humidity / Transport | Max. 95% at 40°C |
Mechanical properties
| Dimensions / Width | 293 mm |
| Dimensions / Height | 328 mm |
| Dimensions / Depth | 80 mm |
| Weight | 7 kg |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
3D CAD models
Certificates
- E225616 UL Certificate of Compliance ACOPOSremote
- EU Declaration FS Servos ACOPOSremote
- EU Declaration Servos ACOPOSremote
- TÜV-certificate - function "Safe Pulse Disabling" für ACOPOSremote(de)
- TÜV-certificate - function "Safe Pulse Disabling" für ACOPOSremote(en)
- UK Declaration FS Servos ACOPOSremote
- UK Declaration Servos ACOPOSremote
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.