B&R 8CVI045S1HCS0.00-1

Uncontrolled and safe stops integrated SinCos encoder connection Integrated connections for local I/O nodes Simplified wiring ACOPOSremote ACOPOSmulti65 inverter module, 4.5 A, AS, IP65, 1x SinCos encoder interface, cold plate mounting

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

Replacing or upgrading a servo component?

Servo amplifiers, motors, encoders and cables are matched sets. If this part is no longer available in its original form, the manufacturer's newer generation usually will not pair with the rest of the axis, so an upgrade normally covers the drive, motor and cables together. Send us the nameplate details and we will confirm availability of an exact spare or scope a compatible upgrade.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

General information
Current-carrying capacity of 15-pin TYCO connector / Power contactsMax. 20 A at 40°C
Support / Dynamic node allocation (DNA)Yes
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / Functional safetyYes
Certifications / ULcULus E225616 Power conversion equipment
Certifications / KCYes
Module typeACOPOSremote module
B&R ID code0xB5CB
Cooling and mounting typeCold plate mounting
DC bus connection
Voltage / Nominal750 VDC
Power dissipation depending on switching frequency / Switching frequency 5 kHz[0.16 * IM² + 5.6 * IM + 55 + (Pout/750)² * 0.25] W
Power dissipation depending on switching frequency / Switching frequency 10 kHz[0.49 * IM² + 4.7 * IM + 95 + (Pout/750)² * 0.25] W
Power dissipation depending on switching frequency / Switching frequency 20 kHz[0.87 * IM² + 10 * IM + 200 + (Pout/750)² * 0.25] W
Line length / Maximum30 m
Continuous power consumptionIn preparation
DC bus capacitance35 µF
Variant15-pin male TYCO connector
24 VDC power supply
Line length / Maximum30 m
Input voltage24 VDC +20% / -25%
Input capacitanceIn preparation
Max. power consumption10 W + P24 V out + PHolding brake + PTrigger
Variant15-pin male TYCO connector
24 VDC output
Variant / 24 VDC, COMM8 connector
Quantity1
Output voltageDepends on the 24 VDC power supply
Continuous currentMax. 8 A (max. 4 A per pin)
Fuse protectionElectronic (per pin)
Motor connection
Reduction of continuous current depending on switching frequency / Switching frequency 5 kHzNo reduction
Reduction of continuous current depending on switching frequency / Switching frequency 10 kHzNo reduction
Reduction of continuous current depending on switching frequency / Switching frequency 20 kHzNo reduction
Reduction of continuous current depending on installation elevation / Starting at 500 m above sea level0.45 A per 1,000 m
Protective measures / Overload protectionYes
Protective measures / Short-circuit and ground fault protectionYes
Variant / U, V, W, PE8-pin speedtec connector, size 1
Variant / Shield connectionYes (via connector housing)
Max. motor line length depending on switching frequency / Switching frequency 5 kHz10 m
Max. motor line length depending on switching frequency / Switching frequency 10 kHz5 m
Max. motor line length depending on switching frequency / Switching frequency 20 kHz5 m
Quantity1
Continuous power per motor connection1.5 kW
Continuous current per motor connection4.5 Aeff
Peak current13.5 Aeff
Nominal switching frequency5 kHz
Possible switching frequencies5 / 10 / 20 kHz
Insulation stress of the connected motor per IEC TS 60034-25:2004Limit value curve A
Max. output frequency598 Hz
Motor holding brake connection
Protective measures / Overload and short-circuit protectionYes
Protective measures / Open-circuit monitoringYes
Protective measures / Undervoltage monitoringYes
Quantity1
Output voltage24 VDC +5.8% / -0%
Continuous current per connection1.1 A
Max. internal resistanceIn preparation
Extinction potentialApprox. 30 V
Max. extinction energy per switching operation1.5 Ws
Max. switching frequency0.5 Hz
Response threshold for open-circuit monitoringApprox. 0.25 A
Response threshold for undervoltage monitoring24 VDC +0% / -4%
Fieldbus
TypePOWERLINK (V1/V2) 100BASE-T (ANSI/IEE 802.3)
VariantInternal 3-port hub, 2x male 15-pin TYCO connector, 1x M12 connector
Line lengthMax. 100 m between two stations (segment length)
Transfer rate100 Mbit/s
Encoder inputs
Electrical isolation / Encoder - ACOPOSremoteNo
Encoder power supply / Protective measures / Overload-proofYes
Encoder power supply / Protective measures / Short-circuit proofYes
Encoder power supply / Output voltage5 V ±5%
Encoder power supply / Load capacity300 mA
Encoder power supply / Sense lines2, compensation of max. 2 x 0.7 V
Sine/Cosine inputs / Signal transmissionDifferential signals, symmetrical
Sine/Cosine inputs / Signal frequency (-3 dB)DC up to 300 kHz
Sine/Cosine inputs / Signal frequency (-5 dB)DC up to 400 kHz
Sine/Cosine inputs / Differential voltage0.5 to 1.25 Vss
Sine/Cosine inputs / Common-mode voltageMax. ±7 V
Sine/Cosine inputs / Terminating resistor120 Ω
Sine/Cosine inputs / ADC resolution12-bit
Reference input / Signal transmissionDifferential signal, symmetrical
Reference input / Differential voltage for low≤-0.2 V
Reference input / Differential voltage for high≥0.2 V
Reference input / Common-mode voltageMax. ±7 V
Reference input / Terminating resistor120 Ω
Position / Resolution @ 1 VSSNumber of encoder lines * 5700
Position / Accuracy-
Position / Noise-
Limit switch inputs / Electrical isolation / Input - ACOPOSremoteNo
Limit switch inputs / Electrical isolation / Input - InputNo
Limit switch inputs / Input voltage / Minimum-12 V
Limit switch inputs / Input voltage / Nominal5 V
Limit switch inputs / Input voltage / Maximum20 V
Limit switch inputs / Switching threshold / Low<0.8 V
Limit switch inputs / Switching threshold / High>2 V
Limit switch inputs / Quantity2
Limit switch inputs / CircuitSource
Limit switch inputs / Input resistance1470 Ω
Limit switch inputs / Switching delayMax. 100 µs
Quantity1
TypeSinCos
Module-side connection15-pin female springtec connector
Status indicatorsUP/DN LEDs
Encoder monitoringYes
Max. encoder cable length10 m
Enable inputs
Electrical isolation / Input - Inverter moduleYes
Electrical isolation / Input - InputYes
Input voltage / Nominal24 VDC
Input voltage / Maximum30 VDC
Switching threshold / Low<5 V
Switching threshold / High>15 V
Switching delay at nominal input voltage / Enable 1 → 0, PWM offMax. 20.5 ms
Switching delay at nominal input voltage / Enable 0 → 1, ready for PWMMax. 100 µs
Quantity2
CircuitSink
Input current at nominal voltageApprox. 30 mA
Modulation compared to ground potentialMax. ±38 V
OSSD signal connectionsPermitted Max. test pulse length: 500 µs
Variant15-pin male TYCO connector
Trigger inputs
Electrical isolation / Input - Inverter moduleNo
Electrical isolation / Input - InputNo
Input voltage / Nominal24 VDC
Input voltage / Maximum30 VDC
Switching threshold / Low<5 V
Switching threshold / High>15 V
Switching delay / Rising edgeIn preparation
Switching delay / Falling edgeIn preparation
Sensor/Actuator power supply / Voltage24 VDC
Sensor/Actuator power supply / Summation currentMax. 250 mA
Quantity2
CircuitSink
Input current at nominal voltageIn preparation
Modulation compared to ground potentialIn preparation
Max. line length30 m
VariantM8 connector
Temperature sensor connection
Quantity1
Resistance range500 Ω to 5 kΩ
Support
Software / ACP10V2.35.1 and higher
Electrical properties
Energy efficiency (IE classification) / Power dissipation relative to continuous apparent powerIE2 (10,25) 2.2% IE2 (50,25) 2.2% IE2 (10,50) 2.4% IE2 (50,50) 2.4% IE2 (90,50) 2.4% IE2 (10,100) 2.9% IE2 (50,100) 2.9% IE2 (90,100) 2.9%
Energy efficiency (IE classification) / Nominal losses in standby mode6.5 W
Discharge capacitance0.1 µF
Operating conditions
Permissible mounting orientations / Hanging verticallyYes
Permissible mounting orientations / Horizontal, face upYes
Permissible mounting orientations / Standing horizontallyYes
Installation elevation above sea level / Nominal0 to 500 m
Installation elevation above sea level / Maximum4000 m
Pollution degree per EN 61800-5-12 (non-conductive pollution)
Overvoltage category per EN 61800-5-1III
Degree of protection per EN 60529IP65
Ambient conditions
Temperature / Operation / Nominal5 to 40°C
Temperature / Operation / Maximum60°C
Temperature / Storage-25 to 55°C
Temperature / Transport-25 to 70°C
Relative humidity / Operation5 to 85%, non-condensing
Relative humidity / Storage5 to 95%, non-condensing
Relative humidity / TransportMax. 95% at 40°C
Mechanical properties
Dimensions / Width137 mm
Dimensions / Height287.2 mm
Dimensions / Depth131 mm
Weight4.8 kg