B&R 8CVI045S1HCS0.00-1
Uncontrolled and safe stops integrated SinCos encoder connection Integrated connections for local I/O nodes Simplified wiring ACOPOSremote ACOPOSmulti65 inverter module, 4.5 A, AS, IP65, 1x SinCos encoder interface, cold plate mounting
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
Servo amplifiers, motors, encoders and cables are matched sets. If this part is no longer available in its original form, the manufacturer's newer generation usually will not pair with the rest of the axis, so an upgrade normally covers the drive, motor and cables together. Send us the nameplate details and we will confirm availability of an exact spare or scope a compatible upgrade.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
General information
| Current-carrying capacity of 15-pin TYCO connector / Power contacts | Max. 20 A at 40°C |
| Support / Dynamic node allocation (DNA) | Yes |
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | In preparation |
| Certifications / Functional safety | Yes |
| Certifications / UL | cULus E225616 Power conversion equipment |
| Certifications / KC | Yes |
| Module type | ACOPOSremote module |
| B&R ID code | 0xB5CB |
| Cooling and mounting type | Cold plate mounting |
DC bus connection
| Voltage / Nominal | 750 VDC |
| Power dissipation depending on switching frequency / Switching frequency 5 kHz | [0.16 * IM² + 5.6 * IM + 55 + (Pout/750)² * 0.25] W |
| Power dissipation depending on switching frequency / Switching frequency 10 kHz | [0.49 * IM² + 4.7 * IM + 95 + (Pout/750)² * 0.25] W |
| Power dissipation depending on switching frequency / Switching frequency 20 kHz | [0.87 * IM² + 10 * IM + 200 + (Pout/750)² * 0.25] W |
| Line length / Maximum | 30 m |
| Continuous power consumption | In preparation |
| DC bus capacitance | 35 µF |
| Variant | 15-pin male TYCO connector |
24 VDC power supply
| Line length / Maximum | 30 m |
| Input voltage | 24 VDC +20% / -25% |
| Input capacitance | In preparation |
| Max. power consumption | 10 W + P24 V out + PHolding brake + PTrigger |
| Variant | 15-pin male TYCO connector |
24 VDC output
| Variant / 24 VDC, COM | M8 connector |
| Quantity | 1 |
| Output voltage | Depends on the 24 VDC power supply |
| Continuous current | Max. 8 A (max. 4 A per pin) |
| Fuse protection | Electronic (per pin) |
Motor connection
| Reduction of continuous current depending on switching frequency / Switching frequency 5 kHz | No reduction |
| Reduction of continuous current depending on switching frequency / Switching frequency 10 kHz | No reduction |
| Reduction of continuous current depending on switching frequency / Switching frequency 20 kHz | No reduction |
| Reduction of continuous current depending on installation elevation / Starting at 500 m above sea level | 0.45 A per 1,000 m |
| Protective measures / Overload protection | Yes |
| Protective measures / Short-circuit and ground fault protection | Yes |
| Variant / U, V, W, PE | 8-pin speedtec connector, size 1 |
| Variant / Shield connection | Yes (via connector housing) |
| Max. motor line length depending on switching frequency / Switching frequency 5 kHz | 10 m |
| Max. motor line length depending on switching frequency / Switching frequency 10 kHz | 5 m |
| Max. motor line length depending on switching frequency / Switching frequency 20 kHz | 5 m |
| Quantity | 1 |
| Continuous power per motor connection | 1.5 kW |
| Continuous current per motor connection | 4.5 Aeff |
| Peak current | 13.5 Aeff |
| Nominal switching frequency | 5 kHz |
| Possible switching frequencies | 5 / 10 / 20 kHz |
| Insulation stress of the connected motor per IEC TS 60034-25:2004 | Limit value curve A |
| Max. output frequency | 598 Hz |
Motor holding brake connection
| Protective measures / Overload and short-circuit protection | Yes |
| Protective measures / Open-circuit monitoring | Yes |
| Protective measures / Undervoltage monitoring | Yes |
| Quantity | 1 |
| Output voltage | 24 VDC +5.8% / -0% |
| Continuous current per connection | 1.1 A |
| Max. internal resistance | In preparation |
| Extinction potential | Approx. 30 V |
| Max. extinction energy per switching operation | 1.5 Ws |
| Max. switching frequency | 0.5 Hz |
| Response threshold for open-circuit monitoring | Approx. 0.25 A |
| Response threshold for undervoltage monitoring | 24 VDC +0% / -4% |
Fieldbus
| Type | POWERLINK (V1/V2) 100BASE-T (ANSI/IEE 802.3) |
| Variant | Internal 3-port hub, 2x male 15-pin TYCO connector, 1x M12 connector |
| Line length | Max. 100 m between two stations (segment length) |
| Transfer rate | 100 Mbit/s |
Encoder inputs
| Electrical isolation / Encoder - ACOPOSremote | No |
| Encoder power supply / Protective measures / Overload-proof | Yes |
| Encoder power supply / Protective measures / Short-circuit proof | Yes |
| Encoder power supply / Output voltage | 5 V ±5% |
| Encoder power supply / Load capacity | 300 mA |
| Encoder power supply / Sense lines | 2, compensation of max. 2 x 0.7 V |
| Sine/Cosine inputs / Signal transmission | Differential signals, symmetrical |
| Sine/Cosine inputs / Signal frequency (-3 dB) | DC up to 300 kHz |
| Sine/Cosine inputs / Signal frequency (-5 dB) | DC up to 400 kHz |
| Sine/Cosine inputs / Differential voltage | 0.5 to 1.25 Vss |
| Sine/Cosine inputs / Common-mode voltage | Max. ±7 V |
| Sine/Cosine inputs / Terminating resistor | 120 Ω |
| Sine/Cosine inputs / ADC resolution | 12-bit |
| Reference input / Signal transmission | Differential signal, symmetrical |
| Reference input / Differential voltage for low | ≤-0.2 V |
| Reference input / Differential voltage for high | ≥0.2 V |
| Reference input / Common-mode voltage | Max. ±7 V |
| Reference input / Terminating resistor | 120 Ω |
| Position / Resolution @ 1 VSS | Number of encoder lines * 5700 |
| Position / Accuracy | - |
| Position / Noise | - |
| Limit switch inputs / Electrical isolation / Input - ACOPOSremote | No |
| Limit switch inputs / Electrical isolation / Input - Input | No |
| Limit switch inputs / Input voltage / Minimum | -12 V |
| Limit switch inputs / Input voltage / Nominal | 5 V |
| Limit switch inputs / Input voltage / Maximum | 20 V |
| Limit switch inputs / Switching threshold / Low | <0.8 V |
| Limit switch inputs / Switching threshold / High | >2 V |
| Limit switch inputs / Quantity | 2 |
| Limit switch inputs / Circuit | Source |
| Limit switch inputs / Input resistance | 1470 Ω |
| Limit switch inputs / Switching delay | Max. 100 µs |
| Quantity | 1 |
| Type | SinCos |
| Module-side connection | 15-pin female springtec connector |
| Status indicators | UP/DN LEDs |
| Encoder monitoring | Yes |
| Max. encoder cable length | 10 m |
Enable inputs
| Electrical isolation / Input - Inverter module | Yes |
| Electrical isolation / Input - Input | Yes |
| Input voltage / Nominal | 24 VDC |
| Input voltage / Maximum | 30 VDC |
| Switching threshold / Low | <5 V |
| Switching threshold / High | >15 V |
| Switching delay at nominal input voltage / Enable 1 → 0, PWM off | Max. 20.5 ms |
| Switching delay at nominal input voltage / Enable 0 → 1, ready for PWM | Max. 100 µs |
| Quantity | 2 |
| Circuit | Sink |
| Input current at nominal voltage | Approx. 30 mA |
| Modulation compared to ground potential | Max. ±38 V |
| OSSD signal connections | Permitted Max. test pulse length: 500 µs |
| Variant | 15-pin male TYCO connector |
Trigger inputs
| Electrical isolation / Input - Inverter module | No |
| Electrical isolation / Input - Input | No |
| Input voltage / Nominal | 24 VDC |
| Input voltage / Maximum | 30 VDC |
| Switching threshold / Low | <5 V |
| Switching threshold / High | >15 V |
| Switching delay / Rising edge | In preparation |
| Switching delay / Falling edge | In preparation |
| Sensor/Actuator power supply / Voltage | 24 VDC |
| Sensor/Actuator power supply / Summation current | Max. 250 mA |
| Quantity | 2 |
| Circuit | Sink |
| Input current at nominal voltage | In preparation |
| Modulation compared to ground potential | In preparation |
| Max. line length | 30 m |
| Variant | M8 connector |
Temperature sensor connection
| Quantity | 1 |
| Resistance range | 500 Ω to 5 kΩ |
Support
| Software / ACP10 | V2.35.1 and higher |
Electrical properties
| Energy efficiency (IE classification) / Power dissipation relative to continuous apparent power | IE2 (10,25) 2.2% IE2 (50,25) 2.2% IE2 (10,50) 2.4% IE2 (50,50) 2.4% IE2 (90,50) 2.4% IE2 (10,100) 2.9% IE2 (50,100) 2.9% IE2 (90,100) 2.9% |
| Energy efficiency (IE classification) / Nominal losses in standby mode | 6.5 W |
| Discharge capacitance | 0.1 µF |
Operating conditions
| Permissible mounting orientations / Hanging vertically | Yes |
| Permissible mounting orientations / Horizontal, face up | Yes |
| Permissible mounting orientations / Standing horizontally | Yes |
| Installation elevation above sea level / Nominal | 0 to 500 m |
| Installation elevation above sea level / Maximum | 4000 m |
| Pollution degree per EN 61800-5-1 | 2 (non-conductive pollution) |
| Overvoltage category per EN 61800-5-1 | III |
| Degree of protection per EN 60529 | IP65 |
Ambient conditions
| Temperature / Operation / Nominal | 5 to 40°C |
| Temperature / Operation / Maximum | 60°C |
| Temperature / Storage | -25 to 55°C |
| Temperature / Transport | -25 to 70°C |
| Relative humidity / Operation | 5 to 85%, non-condensing |
| Relative humidity / Storage | 5 to 95%, non-condensing |
| Relative humidity / Transport | Max. 95% at 40°C |
Mechanical properties
| Dimensions / Width | 137 mm |
| Dimensions / Height | 287.2 mm |
| Dimensions / Depth | 131 mm |
| Weight | 4.8 kg |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
3D CAD models
Certificates
- ACOPOSremote KC certificates
- E225616 UL Certificate of Compliance ACOPOSremote
- EU Declaration FS Servos ACOPOSremote
- EU Declaration Servos ACOPOSremote
- TÜV-certificate - function "Safe Pulse Disabling" für ACOPOSremote(de)
- TÜV-certificate - function "Safe Pulse Disabling" für ACOPOSremote(en)