Servo amplifiers, motors, encoders and cables are matched sets. If this part is no longer available in its original form, the manufacturer's newer generation usually will not pair with the rest of the axis, so an upgrade normally covers the drive, motor and cables together. Send us the nameplate details and we will confirm availability of an exact spare or scope a compatible upgrade.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

General information
Support / Dynamic node allocation (DNA)Yes
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / ULcULus E225616 Power conversion equipment
Slots for plug-in modules1
Mains connection
Terminal connection cross section / Flexible and fine-stranded wires / With wire end sleeve0.75 to 16 mm²
Terminal connection cross section / Approbation data / UL/C-UL-US20 to 4 AWG
Terminal connection cross section / Approbation data / CSA20 to 4 AWG
Network configurationsTT, TN, TN-S, TN-C-S, IT
Mains input voltage3x 200 VAC to 480 VAC ±10%
Frequency50 / 60 Hz ±4%
Installed loadMax. 18.7 kVA
Inrush currentMax. 100 A
Switch-on interval120 s
Integrated line filter per EN 61800-3, category C3No
Power dissipation at device nominal power without braking resistor[81 W + 9.7 V * I + 8.4 W/kW * Pout + 0.25 Ω * I²BR + PVSLOT] * 1.1
Power dissipation remaining in the control cabinetPv_inside = 0.510 * Pv + 1.624 * (T_amb – T_inside)
Max. line length3 m
DC bus connection
Reduction of continuous power depending on mains input voltage / Mains input voltage <3x 400 VAC10 kW * (Mains input voltage [V] / 400 V)
Terminal connection cross sections / Flexible and fine-stranded wires / With wire end sleeves0.75 to 16 mm²
Terminal connection cross sections / Approbation data / UL/C-UL-US20 to 4 AWG
Terminal connection cross sections / Approbation data / CSA20 to 4 AWG
Continuous power10 kW
DC bus capacitance1680 µF
Max. line length3 m
24 VDC power supply
Terminal connection cross sections / Flexible and fine-stranded wires / With wire end sleeves0.25 to 4 mm²
Terminal connection cross sections / Approbation data / UL/C-UL-US24 to 8 AWG
Terminal connection cross sections / Approbation data / CSA24 to 8 AWG
Input voltage24 VDC ±25%
Input capacitance5500 μF
Current consumption2 A + Current for motor holding brake
Max. line length30 m
Motor connection
Accuracy of the safe current / Safety function SLT / SIL 2 / PL d / Cat. 3Hardware upgrade 1.10.2.x: 8.450 A Hardware upgrade 1.10.3.0 or later: 6.943 A
Accuracy of the safe current / Safety function SLT / SIL 2 / PL d / Cat. 23.301 A
Accuracy of the safe current / Safety function SBT / SIL 2 / PL d / Cat. 3Hardware upgrade 1.10.2.x: 7.489 A Hardware upgrade 1.10.3.0 or later: 5.944 A
Accuracy of the safe current / Safety function SBT / SIL 2 / PL d / Cat. 22.498 A
Reduction of continuous current depending on ambient temperature / Mains input voltage: 400 VAC / Switching frequency 5 kHzIn preparation
Reduction of continuous current depending on ambient temperature / Mains input voltage: 400 VAC / Switching frequency 10 kHzIn preparation
Reduction of continuous current depending on ambient temperature / Mains input voltage: 400 VAC / Switching frequency 20 kHzIn preparation
Reduction of continuous current depending on ambient temperature / Mains input voltage: 480 VAC / Switching frequency 5 kHzIn preparation
Reduction of continuous current depending on ambient temperature / Mains input voltage: 480 VAC / Switching frequency 10 kHzIn preparation
Reduction of continuous current depending on ambient temperature / Mains input voltage: 480 VAC / Switching frequency 20 kHzIn preparation
Reduction of continuous current depending on installation elevation / Starting at 500 m above sea level2.4 Aeff per 1000 m
Protective measures / Overload protectionYes
Protective measures / Short-circuit and ground fault protectionYes
Variant / U, V, W, PEConnector
Variant / Shield connectionYes Clamping range of the grounding clamp: 17 to 30 mm
Terminal connection cross section / Flexible and fine-stranded wires / With wire end sleeve0.75 to 16 mm²
Terminal connection cross section / Approbation data / UL/C-UL-US20 to 4 AWG
Terminal connection cross section / Approbation data / CSA20 to 4 AWG
Max. motor line length depending on switching frequency / Switching frequency 5 kHz75 m
Max. motor line length depending on switching frequency / Switching frequency 10 kHz35 m
Max. motor line length depending on switching frequency / Switching frequency 20 kHz20 m
Quantity1
Continuous power per motor connection10 kW
Continuous current per motor connection24 Aeff
Peak current per motor connection60 Aeff
Peak power output25 kW
Nominal switching frequency5 kHz
Possible switching frequencies2.5 / 5 / 10 / 20 kHz
Insulation stress of the connected motor per IEC TS 60034-25:2004Limit value curve A
Max. output frequency598 Hz
Motor holding brake connection
Terminal connection cross section / Flexible and fine-stranded wires / With wire end sleeve0.75 to 16 mm²
Terminal connection cross section / Approbation data / UL/C-UL-US20 to 4 AWG
Terminal connection cross section / Approbation data / CSA20 to 4 AWG
Protective measures / Overload and short-circuit protectionYes
Protective measures / Open-circuit monitoringYes
Protective measures / Undervoltage monitoringYes
Quantity1
Output voltageDepends on the input voltage on connector X2
Continuous current per connection6.5 A
Max. internal resistance0.25 Ω
Extinction potentialApprox. 30 V
Max. extinction energy per switching operation15 Ws
Max. switching frequency0.5 Hz
Response threshold for open-circuit monitoringApprox. 120 mA
Response threshold for undervoltage monitoringApprox. 23 V
Max. breaking current SBC200 mA
Max. line length75 m
Braking resistor
Protective measures / Overload protectionNo
Protective measures / Short-circuit and ground fault protectionShort-circuit protection: Yes Ground fault protection: No
Peak power output45 kW
Continuous power4 kW
Minimum braking resistance (ext.)13 Ω
Max. line length3 m
Fieldbus
TypePOWERLINK V2 controlled node (CN)
Variant2x RJ45, shielded, 2-port hub
Line lengthMax. 100 m between 2 stations (segment length)
Transfer rate100 Mbit/s
Encoder interfaces
Electrical isolation / Encoder - ACOPOS P3No
Encoder power supply / Protective measures / Short-circuit proofYes
Encoder power supply / Protective measures / Overload-proofYes
Encoder power supply / Output voltageConfigurable Typ. 11.45 V ±0.1 V / 5.2 V ±0.1 V
Encoder power supply / Load capacityMax. 300 mA
Encoder power supply / Sense lines2, compensation of max. 2x 0.7 V
Synchronous serial interface / Differential voltage / Minimum2.0 V
Synchronous serial interface / Differential voltage / Maximum6.0 V
Synchronous serial interface / Signal transmissionRS485
Synchronous serial interface / Data transfer rateDepends on the configured encoder type
Quantity1
TypeDigital multi-encoder interface, configurable
Connections8-pin female Mini I/O connector
Status indicatorsNone
Max. encoder cable length75 m Depends on the cross section of the power supply wires in the encoder cable
Max. power consumption per encoder interfacePENCODER [W] = U24V [V] * (IENCODER [A] * 0.7) + 0.5 W
Trigger inputs
Electrical isolation / Input - ACOPOS P3Yes
Electrical isolation / Input - InputYes
Input voltage / Nominal24 VDC
Input voltage / Maximum30 VDC
Switching threshold / Low<5 V
Switching threshold / High>15 V
Switching delay / Rising edge<51 µs
Switching delay / Falling edge<52 µs
Terminal connection cross section / Flexible and fine-stranded wires / With wire end sleeve0.25 to 2.5 mm²
Terminal connection cross section / Approbation data / UL/C-UL-US26 to 12 AWG
Terminal connection cross section / Approbation data / CSA26 to 12 AWG
Quantity2
CircuitSink
Input current at nominal voltage7 mA
Modulation compared to ground potentialMax. ±38 V
Max. line length100 m
Temperature sensor connection
Quantity1
Resistance range500 Ω to 5 kΩ
Support
Motion system / mapp Motion5.05.0 and higher
Motion system / ACP10/ARNC05.03.0 and higher
Electrical properties
Energy efficiency (IE classification) / Power dissipation relative to continuous apparent powerIE2 (10,25) 1.2% IE2 (50,25) 1.2% IE2 (10,50) 1.4% IE2 (50,50) 1.4% IE2 (90,50) 1.5% IE2 (10,100) 2% IE2 (50,100) 2.2% IE2 (90,100) 2.4%
Energy efficiency (IE classification) / Nominal losses in standby mode15.8 W
Operating conditions
Permissible mounting orientations / Hanging verticallyYes
Permissible mounting orientations / Horizontal, face upNo
Permissible mounting orientations / Standing horizontallyNo
Installation elevation above sea level / Nominal0 to 500 m
Installation elevation above sea level / Maximum4000 m
Pollution degree per EN 61800-5-12 (non-conductive pollution)
Overvoltage category per EN 61800-5-1III
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Minimum-25°C
Temperature / Operation / Nominal5 to 40°C
Temperature / Operation / Maximum55°C
Temperature / Storage-25 to 55°C
Temperature / Transport-25 to 70°C
Relative humidity / Operation5 to 85 %, non-condensing
Relative humidity / Storage5 to 95%
Relative humidity / Transport95% at 40°C
Mechanical properties
Dimensions / Depth / Cold plate281.5 mm (with 8EXA front cover: 284 mm)
Dimensions / Depth / Pass-through mounting277.5 mm (with 8EXA front cover: 280 mm)
Dimensions / Width133 mm
Dimensions / Height374 mm
Dimensions / Depth264.50 mm (with 8EXA front cover: 267 mm)
Weight9.4 kg