B&R 8EI034HCSS0.XXXX-1
ACOPOS P3 servo drive, 3x 200-480 VAC, 34 A, SafeMOTION, 1 axis, AS, cold plate or pass-through mounting
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
Servo amplifiers, motors, encoders and cables are matched sets. If this part is no longer available in its original form, the manufacturer's newer generation usually will not pair with the rest of the axis, so an upgrade normally covers the drive, motor and cables together. Send us the nameplate details and we will confirm availability of an exact spare or scope a compatible upgrade.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
General information
| Support / Dynamic node allocation (DNA) | Yes |
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | In preparation |
| Certifications / UL | cULus E225616 Power conversion equipment |
| Slots for plug-in modules | 1 |
Mains connection
| Terminal connection cross section / Flexible and fine-stranded wires / With wire end sleeve | 0.75 to 16 mm² |
| Terminal connection cross section / Approbation data / UL/C-UL-US | 20 to 4 AWG |
| Terminal connection cross section / Approbation data / CSA | 20 to 4 AWG |
| Network configurations | TT, TN, TN-S, TN-C-S, IT |
| Mains input voltage | 3x 200 VAC to 480 VAC ±10% |
| Frequency | 50 / 60 Hz ±4% |
| Installed load | Max. 26.4 kVA |
| Inrush current | Max. 100 A |
| Switch-on interval | 120 s |
| Integrated line filter per EN 61800-3, category C3 | No |
| Power dissipation at device nominal power without braking resistor | [81 W + 9.7 V * I + 8.4 W/kW * Pout + 0.25 Ω * I²BR + PVSLOT] * 1.1 |
| Power dissipation remaining in the control cabinet | Pv_inside = 0.510 * Pv + 1.624 * (T_amb – T_inside) |
| Max. line length | 3 m |
DC bus connection
| Reduction of continuous power depending on mains input voltage / Mains input voltage <3x 400 VAC | 14 kW * (Mains input voltage [V] / 400 V) |
| Terminal connection cross sections / Flexible and fine-stranded wires / With wire end sleeves | 0.75 to 16 mm² |
| Terminal connection cross sections / Approbation data / UL/C-UL-US | 20 to 4 AWG |
| Terminal connection cross sections / Approbation data / CSA | 20 to 4 AWG |
| Continuous power | 14 kW |
| DC bus capacitance | 1680 µF |
| Max. line length | 3 m |
24 VDC power supply
| Terminal connection cross sections / Flexible and fine-stranded wires / With wire end sleeves | 0.25 to 4 mm² |
| Terminal connection cross sections / Approbation data / UL/C-UL-US | 24 to 8 AWG |
| Terminal connection cross sections / Approbation data / CSA | 24 to 8 AWG |
| Input voltage | 24 VDC ±25% |
| Input capacitance | 5500 μF |
| Current consumption | 2 A + Current for motor holding brake |
| Max. line length | 30 m |
Motor connection
| Accuracy of the safe current / Safety function SLT / SIL 2 / PL d / Cat. 3 | Hardware upgrade 1.10.2.x: 9.098 A Hardware upgrade 1.10.3.0 or later: 7.614 A |
| Accuracy of the safe current / Safety function SLT / SIL 2 / PL d / Cat. 2 | 3.804 A |
| Accuracy of the safe current / Safety function SBT / SIL 2 / PL d / Cat. 3 | Hardware upgrade 1.10.2.x: 7.732 A Hardware upgrade 1.10.3.0 or later: 6.196 A |
| Accuracy of the safe current / Safety function SBT / SIL 2 / PL d / Cat. 2 | 2.666 A |
| Reduction of continuous current depending on ambient temperature / Mains input voltage: 400 VAC / Switching frequency 5 kHz | In preparation |
| Reduction of continuous current depending on ambient temperature / Mains input voltage: 400 VAC / Switching frequency 10 kHz | In preparation |
| Reduction of continuous current depending on ambient temperature / Mains input voltage: 400 VAC / Switching frequency 20 kHz | In preparation |
| Reduction of continuous current depending on ambient temperature / Mains input voltage: 480 VAC / Switching frequency 5 kHz | In preparation |
| Reduction of continuous current depending on ambient temperature / Mains input voltage: 480 VAC / Switching frequency 10 kHz | In preparation |
| Reduction of continuous current depending on ambient temperature / Mains input voltage: 480 VAC / Switching frequency 20 kHz | In preparation |
| Reduction of continuous current depending on installation elevation / Starting at 500 m above sea level | 3.4 Aeff per 1000 m |
| Protective measures / Overload protection | Yes |
| Protective measures / Short-circuit and ground fault protection | Yes |
| Variant / U, V, W, PE | Connector |
| Variant / Shield connection | Yes Clamping range of the grounding clamp: 17 to 30 mm |
| Terminal connection cross section / Flexible and fine-stranded wires / With wire end sleeve | 0.75 to 16 mm² |
| Terminal connection cross section / Approbation data / UL/C-UL-US | 20 to 4 AWG |
| Terminal connection cross section / Approbation data / CSA | 20 to 4 AWG |
| Max. motor line length depending on switching frequency / Switching frequency 5 kHz | 75 m |
| Max. motor line length depending on switching frequency / Switching frequency 10 kHz | 35 m |
| Max. motor line length depending on switching frequency / Switching frequency 20 kHz | 20 m |
| Quantity | 1 |
| Continuous power per motor connection | 14 kW |
| Continuous current per motor connection | 34 Aeff |
| Peak current per motor connection | 85 Aeff |
| Peak power output | 35 kW |
| Nominal switching frequency | 5 kHz |
| Possible switching frequencies | 2.5 / 5 / 10 / 20 kHz |
| Insulation stress of the connected motor per IEC TS 60034-25:2004 | Limit value curve A |
| Max. output frequency | 598 Hz |
Motor holding brake connection
| Terminal connection cross section / Flexible and fine-stranded wires / With wire end sleeve | 0.75 to 16 mm² |
| Terminal connection cross section / Approbation data / UL/C-UL-US | 20 to 4 AWG |
| Terminal connection cross section / Approbation data / CSA | 20 to 4 AWG |
| Protective measures / Overload and short-circuit protection | Yes |
| Protective measures / Open-circuit monitoring | Yes |
| Protective measures / Undervoltage monitoring | Yes |
| Quantity | 1 |
| Output voltage | Depends on the input voltage on connector X2 |
| Continuous current per connection | 6.5 A |
| Max. internal resistance | 0.25 Ω |
| Extinction potential | Approx. 30 V |
| Max. extinction energy per switching operation | 15 Ws |
| Max. switching frequency | 0.5 Hz |
| Response threshold for open-circuit monitoring | Approx. 120 mA |
| Response threshold for undervoltage monitoring | Approx. 23 V |
| Max. breaking current SBC | 200 mA |
| Max. line length | 75 m |
Braking resistor
| Protective measures / Overload protection | No |
| Protective measures / Short-circuit and ground fault protection | Short-circuit protection: Yes Ground fault protection: No |
| Peak power output | 45 kW |
| Continuous power | 4 kW |
| Minimum braking resistance (ext.) | 13 Ω |
| Max. line length | 3 m |
Fieldbus
| Type | POWERLINK V2 controlled node (CN) |
| Variant | 2x RJ45, shielded, 2-port hub |
| Line length | Max. 100 m between 2 stations (segment length) |
| Transfer rate | 100 Mbit/s |
Encoder interfaces
| Electrical isolation / Encoder - ACOPOS P3 | No |
| Encoder power supply / Protective measures / Short-circuit proof | Yes |
| Encoder power supply / Protective measures / Overload-proof | Yes |
| Encoder power supply / Output voltage | Configurable Typ. 11.45 V ±0.1 V / 5.2 V ±0.1 V |
| Encoder power supply / Load capacity | Max. 300 mA |
| Encoder power supply / Sense lines | 2, compensation of max. 2x 0.7 V |
| Synchronous serial interface / Differential voltage / Minimum | 2.0 V |
| Synchronous serial interface / Differential voltage / Maximum | 6.0 V |
| Synchronous serial interface / Signal transmission | RS485 |
| Synchronous serial interface / Data transfer rate | Depends on the configured encoder type |
| Quantity | 1 |
| Type | Digital multi-encoder interface, configurable |
| Connections | 8-pin female Mini I/O connector |
| Status indicators | None |
| Max. encoder cable length | 75 m Depends on the cross section of the power supply wires in the encoder cable |
| Max. power consumption per encoder interface | PENCODER [W] = U24V [V] * (IENCODER [A] * 0.7) + 0.5 W |
Trigger inputs
| Electrical isolation / Input - ACOPOS P3 | Yes |
| Electrical isolation / Input - Input | Yes |
| Input voltage / Nominal | 24 VDC |
| Input voltage / Maximum | 30 VDC |
| Switching threshold / Low | <5 V |
| Switching threshold / High | >15 V |
| Switching delay / Rising edge | <51 µs |
| Switching delay / Falling edge | <52 µs |
| Terminal connection cross section / Flexible and fine-stranded wires / With wire end sleeve | 0.25 to 2.5 mm² |
| Terminal connection cross section / Approbation data / UL/C-UL-US | 26 to 12 AWG |
| Terminal connection cross section / Approbation data / CSA | 26 to 12 AWG |
| Quantity | 2 |
| Circuit | Sink |
| Input current at nominal voltage | 7 mA |
| Modulation compared to ground potential | Max. ±38 V |
| Max. line length | 100 m |
Temperature sensor connection
| Quantity | 1 |
| Resistance range | 500 Ω to 5 kΩ |
Support
| Motion system / mapp Motion | 5.05.0 and higher |
| Motion system / ACP10/ARNC0 | 5.03.0 and higher |
Electrical properties
| Energy efficiency (IE classification) / Power dissipation relative to continuous apparent power | IE2 (10,25) 1% IE2 (50,25) 1% IE2 (10,50) 1.2% IE2 (50,50) 1.3% IE2 (90,50) 1.4% IE2 (10,100) 1.9% IE2 (50,100) 2.1% IE2 (90,100) 2.4% |
| Energy efficiency (IE classification) / Nominal losses in standby mode | 15.8 W |
Operating conditions
| Permissible mounting orientations / Hanging vertically | Yes |
| Permissible mounting orientations / Horizontal, face up | No |
| Permissible mounting orientations / Standing horizontally | No |
| Installation elevation above sea level / Nominal | 0 to 500 m |
| Installation elevation above sea level / Maximum | 4000 m |
| Pollution degree per EN 61800-5-1 | 2 (non-conductive pollution) |
| Overvoltage category per EN 61800-5-1 | III |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature / Operation / Minimum | -25°C |
| Temperature / Operation / Nominal | 5 to 40°C |
| Temperature / Operation / Maximum | 55°C |
| Temperature / Storage | -25 to 55°C |
| Temperature / Transport | -25 to 70°C |
| Relative humidity / Operation | 5 to 85 %, non-condensing |
| Relative humidity / Storage | 5 to 95% |
| Relative humidity / Transport | 95% at 40°C |
Mechanical properties
| Dimensions / Depth / Cold plate | 281.5 mm (with 8EXA front cover: 284 mm) |
| Dimensions / Depth / Pass-through mounting | 277.5 mm (with 8EXA front cover: 280 mm) |
| Dimensions / Width | 133 mm |
| Dimensions / Height | 374 mm |
| Dimensions / Depth | 264.50 mm (with 8EXA front cover: 267 mm) |
| Weight | 9.4 kg |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
Manuals
3D CAD models
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.