B&R 8EI2X2MWD10.C700-1
ACOPOS P3 servo drive, 3x 200-230 VAC, 1x 110-230 VAC, 2.2 A, 1 digital multi-standard encoder interface per axis, 2 axes, wall mounting, 8EAC0122.003-1, two-row connector set, cover, integrated braking resistor
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
Servo amplifiers, motors, encoders and cables are matched sets. If this part is no longer available in its original form, the manufacturer's newer generation usually will not pair with the rest of the axis, so an upgrade normally covers the drive, motor and cables together. Send us the nameplate details and we will confirm availability of an exact spare or scope a compatible upgrade.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
General information
| Support / Dynamic node allocation (DNA) | Yes |
| Slots for plug-in modules | 1 |
Mains connection
| Network configurations | TN-S, TN-C-S with grounded neutral |
| Mains input voltage | 1x 110 VAC to 230 VAC ±10% 3x 200 VAC to 230 VAC ±10% |
| Frequency | 50 / 60 Hz ±4% |
| Installed load | Max. 2.5 kVA |
| Inrush current | Max. 22 A |
| Switch-on interval | Typ. 60 s |
| Integrated line filter per EN 61800-3, category C3 | No |
| Power dissipation at device nominal power without braking resistor | [(35 + 10 * PAVG [kW] + 5.8 * (IAX1 [A] + IAX2 [A]) + 0.25 * (IBR1² [A] + IBR2² [A]) + PVSLOT) * 1.1] [W] |
DC bus connection
| DC bus capacitance | 1880 µF |
24 VDC power supply
| Input voltage | 24 VDC ±25% |
| Input capacitance | 5507 µF |
| Current consumption | 1.2 A + Current for motor holding brake |
Motor connection
| Reduction of continuous current depending on switching frequency / Switching frequency 5 kHz | No reduction |
| Reduction of continuous current depending on switching frequency / Switching frequency 10 kHz | No reduction |
| Reduction of continuous current depending on switching frequency / Switching frequency 20 kHz | No reduction |
| Reduction of continuous current depending on installation elevation / Starting at 500 m above sea level | 0.22 Aeff per 1000 m |
| Protective measures / Overload protection | Yes |
| Protective measures / Short-circuit and ground fault protection | Yes |
| Variant / U, V, W, PE | Connector |
| Variant / Shield connection | Yes |
| Terminal connection cross section / Flexible and fine-stranded wires / With wire end sleeve | 1.5 to 6 mm² |
| Terminal connection cross section / Approbation data / UL/C-UL-US | 24 to 8 AWG |
| Terminal connection cross section / Approbation data / CSA | 24 to 8 AWG |
| Max. motor line length depending on switching frequency / Switching frequency 5 kHz | 75 m |
| Max. motor line length depending on switching frequency / Switching frequency 10 kHz | 37.5 m |
| Max. motor line length depending on switching frequency / Switching frequency 20 kHz | 18.75 m |
| Quantity | 2 |
| Continuous power per motor connection | 0.5 / 0.5 kW |
| Continuous current per motor connection | 2.2 / 2.2 Aeff |
| Peak current per motor connection | 6 / 6 Aeff |
| Peak power output | 1.25 kW |
| Nominal switching frequency | 5 kHz |
| Possible switching frequencies | 5 / 10 / 20 kHz |
| Insulation stress of the connected motor per IEC TS 60034-25:2004 | Limit value curve A |
| Max. output frequency | 598 Hz |
Motor holding brake connection
| Protective measures / Overload and short-circuit protection | Yes |
| Protective measures / Open-circuit monitoring | Yes |
| Protective measures / Undervoltage monitoring | Yes |
| Quantity | 2 |
| Output voltage | Depends on the input voltage on connector X2 |
| Continuous current per connection | 1.3 A |
| Max. internal resistance | 0.25 Ω |
| Extinction potential | Approx. 30 V |
| Max. extinction energy per switching operation | 1.5 Ws |
| Max. switching frequency | 0.5 Hz |
| Response threshold for open-circuit monitoring | Approx. 30 mA |
Braking resistor
| Peak power int./ext. | 1.5 kW / 11 kW |
| Continuous power int./ext. | 150 W / 970 W |
| Minimum braking resistance (ext.) | 12 Ω |
Enable inputs
| Electrical isolation / Input - ACOPOS P3 | Yes |
| Electrical isolation / Input - Input | Yes |
| Input voltage / Nominal | 24 VDC |
| Input voltage / Maximum | 30 VDC |
| Switching threshold / Low | <5 V |
| Switching threshold / High | >15 V |
| Switching delay at nominal input voltage / Enable 1 → 0, PWM off | 2 ms |
| Switching delay at nominal input voltage / Enable 0 → 1, ready for PWM | 0.3 ms |
| Quantity | 2 |
| Circuit | Sink |
| Input current at nominal voltage | Approx. 9 mA |
| Modulation compared to ground potential | Max. ±38 V |
| OSSD signal connections | 0.5 ms |
Encoder interfaces
| Electrical isolation / Encoder - ACOPOS P3 | No |
| Encoder power supply / Protective measures / Short-circuit proof | Yes |
| Encoder power supply / Protective measures / Overload-proof | Yes |
| Encoder power supply / Output voltage | Typ. 11.4 V |
| Encoder power supply / Load capacity | 300 mA |
| Synchronous serial interface / Signal transmission | RS485 |
| Synchronous serial interface / Data transfer rate | 6.25 Mbit/s |
| Quantity | 2 |
| Type | EnDat 2.2 |
| Connections | 8-pin female Mini I/O connector |
| Status indicators | None |
| Encoder monitoring | No |
| Max. encoder cable length | 100 m Depends on the cross section of the power supply wires in the encoder cable |
| Max. power consumption per encoder interface | PENCODER [W] = U24V [V] * (IENCODER [A] * 0.7) + 0.5 W |
Trigger inputs
| Electrical isolation / Input - ACOPOS P3 | Yes |
| Electrical isolation / Input - Input | Yes |
| Input voltage / Nominal | 24 VDC |
| Input voltage / Maximum | 30 VDC |
| Switching threshold / Low | <5 V |
| Switching threshold / High | >15 V |
| Switching delay / Rising edge | <2 µs |
| Switching delay / Falling edge | <1 µs |
| Quantity | 2 |
| Circuit | Sink |
| Input current at nominal voltage | Approx. 4 mA |
| Modulation compared to ground potential | Max. ±38 V |
Temperature sensor connection
| Quantity | 2 |
| Resistance range | 500 Ω to 5 kΩ |
Support
| Software / ACP10 | V3.12.1 |
Operating conditions
| Permissible mounting orientations / Hanging vertically | Yes |
| Permissible mounting orientations / Standing horizontally | In preparation |
| Installation elevation above sea level / Nominal | 0 to 500 m |
| Installation elevation above sea level / Maximum | 4000 m |
| Pollution degree per EN 61800-5-1 | 2 (non-conductive pollution) |
| Overvoltage category per EN 61800-5-1 | III |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature / Operation / Nominal | 5 to 40°C |
| Temperature / Operation / Maximum | 55°C |
| Temperature / Storage | -25 to 55°C |
| Temperature / Transport | -25 to 70°C |
| Relative humidity / Operation | 5 to 85%, non-condensing |
| Relative humidity / Storage | 5 to 95% |
| Relative humidity / Transport | 95% at 40°C |
Mechanical properties
| Dimensions / Depth / Wall mounting | 258.5 mm (with 8EXA front cover: 261 mm) |
| Dimensions / Width | 66 mm |
| Dimensions / Height | 374 mm |
| Weight | 4 kg |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Manuals
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.