IAC

B&R 8EI8X8MWT10.0200-1

ACOPOS P3 servo drive, 3x 200-230 VAC, 1x 110-230 VAC, 8.8 A, 1 digital multi-standard encoder interface per axis, 3 axes, wall mounting, one-row connector set, cover

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

Replacing or upgrading a servo component?

Servo amplifiers, motors, encoders and cables are matched sets. If this part is no longer available in its original form, the manufacturer's newer generation usually will not pair with the rest of the axis, so an upgrade normally covers the drive, motor and cables together. Send us the nameplate details and we will confirm availability of an exact spare or scope a compatible upgrade.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

General information
Support / Dynamic node allocation (DNA)Yes
Slots for plug-in modules1
Mains connection
Network configurationsTN-S, TN-C-S with grounded neutral
Mains input voltage1x 110 VAC to 230 VAC ±10% 3x 200 VAC to 230 VAC ±10%
Frequency50 / 60 Hz ±4%
Installed loadMax. 5 kVA
Inrush currentMax. 22 A
Switch-on intervalTyp. 60 s
Integrated line filter per EN 61800-3, category C3No
Power dissipation at device nominal power without braking resistor[(40 + 10 * PAVG [kW] + 5.8 * (IAX1 [A] + IAX2 [A] + IAX3 [A]) + 0.25 * (IBR1² [A] + IBR2² [A] + IBR3² [A]) + PVSLOT) * 1.1] [W]
DC bus connection
DC bus capacitance1880 µF
24 VDC power supply
Input voltage24 VDC ±25%
Input capacitance5507 µF
Current consumption1.2 A + Current for motor holding brake
Motor connection
Reduction of continuous current depending on switching frequency / Switching frequency 5 kHz1.375 A/K (starting at 52.0°C)
Reduction of continuous current depending on switching frequency / Switching frequency 10 kHz0.393 A/K (starting at 45.5°C)
Reduction of continuous current depending on switching frequency / Switching frequency 20 kHz0.120 A/K (starting at 5.9°C)
Reduction of continuous current depending on installation elevation / Starting at 500 m above sea level0.88 Aeff per 1000 m
Protective measures / Overload protectionYes
Protective measures / Short-circuit and ground fault protectionYes
Variant / U, V, W, PEConnector
Variant / Shield connectionYes
Terminal connection cross section / Flexible and fine-stranded wires / With wire end sleeve1.5 to 6 mm²
Terminal connection cross section / Approbation data / UL/C-UL-US24 to 8 AWG
Terminal connection cross section / Approbation data / CSA24 to 8 AWG
Max. motor line length depending on switching frequency / Switching frequency 5 kHz75 m
Max. motor line length depending on switching frequency / Switching frequency 10 kHz37.5 m
Max. motor line length depending on switching frequency / Switching frequency 20 kHz18.75 m
Quantity3
Continuous power per motor connection2 / 2 / 2 kW
Continuous current per motor connection8.8 / 8.8 / 8.8 Aeff
Peak current per motor connection24 / 24 / 24 Aeff
Peak power output5 kW
Nominal switching frequency5 kHz
Possible switching frequencies5 / 10 / 20 kHz
Insulation stress of the connected motor per IEC TS 60034-25:2004Limit value curve A
Max. output frequency598 Hz
Motor holding brake connection
Protective measures / Overload and short-circuit protectionYes
Protective measures / Open-circuit monitoringYes
Protective measures / Undervoltage monitoringYes
Quantity3
Output voltageDepends on the input voltage on connector X2
Continuous current per connection1.3 A
Max. internal resistance0.25 Ω
Extinction potentialApprox. 30 V
Max. extinction energy per switching operation1.5 Ws
Max. switching frequency0.5 Hz
Response threshold for open-circuit monitoringApprox. 30 mA
Braking resistor
Peak power int./ext.1.5 kW / 11 kW
Continuous power int./ext.150 W / 970 W
Minimum braking resistance (ext.)12 Ω
Enable inputs
Electrical isolation / Input - ACOPOS P3Yes
Electrical isolation / Input - InputYes
Input voltage / Nominal24 VDC
Input voltage / Maximum30 VDC
Switching threshold / Low<5 V
Switching threshold / High>15 V
Switching delay at nominal input voltage / Enable 1 → 0, PWM off2 ms
Switching delay at nominal input voltage / Enable 0 → 1, ready for PWM0.3 ms
Quantity2
CircuitSink
Input current at nominal voltageApprox. 9 mA
Modulation compared to ground potentialMax. ±38 V
OSSD signal connections0.5 ms
Encoder interfaces
Electrical isolation / Encoder - ACOPOS P3No
Encoder power supply / Protective measures / Short-circuit proofYes
Encoder power supply / Protective measures / Overload-proofYes
Encoder power supply / Output voltageTyp. 11.4 V
Encoder power supply / Load capacity300 mA
Synchronous serial interface / Signal transmissionRS485
Synchronous serial interface / Data transfer rate6.25 Mbit/s
Quantity3
TypeEnDat 2.2
Connections8-pin female Mini I/O connector
Status indicatorsNone
Encoder monitoringNo
Max. encoder cable length100 m Depends on the cross section of the power supply wires in the encoder cable
Max. power consumption per encoder interfacePENCODER [W] = U24V [V] * (IENCODER [A] * 0.7) + 0.5 W
Trigger inputs
Electrical isolation / Input - ACOPOS P3Yes
Electrical isolation / Input - InputYes
Input voltage / Nominal24 VDC
Input voltage / Maximum30 VDC
Switching threshold / Low<5 V
Switching threshold / High>15 V
Switching delay / Rising edge<2 µs
Switching delay / Falling edge<1 µs
Quantity2
CircuitSink
Input current at nominal voltageApprox. 4 mA
Modulation compared to ground potentialMax. ±38 V
Temperature sensor connection
Quantity3
Resistance range500 Ω to 5 kΩ
Operating conditions
Permissible mounting orientations / Hanging verticallyYes
Permissible mounting orientations / Standing horizontallyIn preparation
Installation elevation above sea level / Nominal0 to 500 m
Installation elevation above sea level / Maximum4000 m
Pollution degree per EN 61800-5-12 (non-conductive pollution)
Overvoltage category per EN 61800-5-1III
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Nominal5 to 40°C
Temperature / Operation / Maximum55°C
Temperature / Storage-25 to 55°C
Temperature / Transport-25 to 70°C
Relative humidity / Operation5 to 85%, non-condensing
Relative humidity / Storage5 to 95%
Relative humidity / Transport95% at 40°C
Mechanical properties
Dimensions / Depth / Wall mounting258.5 mm (with 8EXA front cover: 261 mm)
Dimensions / Width66 mm
Dimensions / Height374 mm
Weight4 kg

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.