B&R 8F1I01.AB2B.0000-1
ACOPOStrak curved segment A, suitable for diverters
Lifecycle & replacement
Lifecycle status not indexed
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
General information
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | In preparation |
| Certifications / UL | cULus E225616 Power conversion equipment |
Power connection
| Power supply | Power supply only in conjunction with 80PS080X3.10-01 and 8F1OA.01B.0000-1 or 8B0C0320Hx00.B00-1 |
| Input voltage | Max. 58 VDC |
| Input current | Max. 31 A |
| Power dissipation | Max. 30 W |
| Derating depending on installation elevation | In preparation |
| Switching frequency | 40 kHz |
| DC bus capacitance | 0.95 mF ±20% |
| Max. line length | 30 m between 2 stations |
DC bus connection
| Protective measures / Overload protection | No |
| Protective measures / Short-circuit and ground fault protection | No |
Fieldbus
| Type | POWERLINK V2 controlled node (CN) |
| Variant | 2x M12 x-cod shielded, 1x M12 a-cod shielded, 3-port hub |
| Max. line length | 30 m |
| Transfer rate | 100 Mbit/s |
Enable inputs
| Electrical isolation / Input - ACOPOStrak | Yes |
| Input voltage / Nominal | 24 VDC |
| Input voltage / Maximum | 30 VDC |
| Switching threshold / Low | <5 V |
| Switching threshold / High | Typ. 15 V Max. 19 V |
| Switching delay at nominal input voltage / Enable 1 → 0, PWM off | 42 ms |
| Switching delay at nominal input voltage / Enable 0 → 1, ready for PWM | 3 ms typ. |
| Quantity | 1 |
| Circuit | Sink |
| Input current at nominal voltage | Approx. 5 mA |
| Modulation compared to ground potential | Max. ±38 V |
| OSSD signal connections | 0.5 ms |
| Max. line length | 30 m between 2 stations |
Support
| Motion system / mapp Motion | V5.12.3 or higher |
Operating conditions
| Mounting orientation / Any | Yes |
| Installation elevation above sea level / Nominal | 0 to 500 m |
| Installation elevation above sea level / Maximum | 4000 m |
| Degree of protection per EN 60529 | IP65 |
| Degree of protection per UL 50 | Type 12 |
Ambient conditions
| Temperature / Operation / Nominal | 5 to 40°C |
| Temperature / Storage | -25 to 55°C |
| Temperature / Transport | -25 to 70°C |
| Relative humidity / Operation | 5 to 85%, non-condensing |
| Relative humidity / Storage | 5 to 95%, non-condensing |
| Relative humidity / Transport | Max. 95% at 40°C |
Mechanical properties
| Dimensions / Width | 446 mm |
| Dimensions / Height | 85.5 mm |
| Dimensions / Depth | 132 mm |
| Weight | 9.6 kg |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
Manuals
3D CAD models
ECAD / EPLAN
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.