IAC

B&R 8FLI31.2424.00I-1

ACOPOS 6D segment S3 240 x 240 mm

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

General information
Certifications / CEYes
Certifications / CRA (Cyber Resilience Act)Non-compliant
Power connection
Power supplyPower supply only in conjunction with 80PS080X3.10-01 and 8F1OA.01B.0000-1 or 8B0C0320Hx00.B00-1
Input voltage36 to 58 VDC
Input currentMax. 31 A
Max. line length10 m
Max. power consumption600 W
DC bus connection
Protective measures / Overload protectionNo
Protective measures / Short-circuit and ground fault protectionNo
Fieldbus
Type6D Link
Execution4x HDMI
Line length0.5 m between adjacent stations Max. 3 m from ACOPOS 6D controller
Transfer rate-
Enable inputs
Switching threshold / Low0 to 4 V
Switching threshold / High18 to 30 V
Operating conditions
Mounting orientation / HorizontalYes
Installation elevation above sea level / Nominal0 to 500 m
Installation elevation above sea level / Maximum4000 m
Degree of protection per EN 60529IP65/IP67
Max. motor temperature during operation45°C
Ambient conditions
Temperature / Operation / Nominal5 to 40°C
Temperature / Storage-25 to 55°C
Temperature / Transport-25 to 70°C
Relative humidity / Operation5 to 80%, non-condensing
Relative humidity / Storage5 to 95%
Relative humidity / Transport95% at 40°C
Mechanical properties
Dimensions / Width239.7 mm
Dimensions / Length239.7 mm
Dimensions / Height70 mm
Weight6.6 kg
Max. pressing force on segment surface1000 N at 10 x 10⁶ cycles
Max. tightening torqueScrew thread M5x0.8 mm, min. 5 mm thread depth: 8 Nm Screw thread M8x1.25 mm, min. 10 mm thread depth: 30 Nm
Cooling
Water cooling / Inlet/outlet fittingsPush-to-connect, 3/8 inch hose outer diameter
Water cooling / Maximum pressure3.4 bar
Water cooling / Flow factor Kv (single segment)0.42 m³/h
Water cooling / Maximum recommended number of serially cooled segments8 segments
Water cooling / Compatible fluidsDistilled water, EuroTerm 131 (and other liquids that are noncorrosive to aluminum or stainless steel can be used)
OptionsPassive, air convection or liquid cooling

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.