IAC

B&R 8GA55-110hh003klmm

Angular PG, i = 003, 1-stage, IP54:

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Gearbox
Number of gear stages1
Gear ratio i3
Nominal output torque T2N [Nm]80
Max. output torque T2max [Nm]128
Emergency switch-off torque T2stop [Nm]360
Idle torque [Nm] at 20°C and 3000 rpm2.3
Max. average drive speed n1N50% [rpm] at 50% T2N and S12200
Max. average drive speed n1N100% [rpm] at 100% T2N and S11700
Max. drive speed n1max [rpm]6500
Max. backlash Jt [arcmin]11
Torsional rigidity Ct21 [Nm/arcmin]69.4
Max. radial force Frmax [N] for 30,000 h2100
Max. radial force Frmax [N] for 20,000 h2400
Max. axial force Famax [N] for 30,000 h3300
Max. axial force Famax [N] for 20,000 h3300
Operating noise LPA [dB(A)]75
Efficiency at full load ŋ [%]94
Min. operating temperature BTempmin [°C]-25
Max. operating temperature BTempmax [°C]90
Mounting orientationAny
Degree of protectionIP54
Weight m [kg]13
Moment of inertia J1 [kgcm²]3.914

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.