IAC

B&R 8GA65-142HH032KLMM

Angel PG, i = 032, 2 stages, IP 65

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Gearbox
Number of gear stages2
Gear ratio i32
Nominal output torque T2N [Nm]360
Max. output torque T2max [Nm]576
Emergency switch-off torque T2stop [Nm]1200
Idle torque [Nm] at 20°C and 3000 rpm6.4
Max. average drive speed n1N50% [rpm] at 50% T2N and S11350
Max. average drive speed n1N100% [rpm] at 100% T2N and S11150
Max. drive speed n1max [rpm]9500
Max. backlash Jt [arcmin]7
Reduced backlash Jt [arcmin] less than0
Torsional rigidity Ct21 [Nm/arcmin]58
Tilt tension C2K [Nm/arcmin]0
Max. breakdown torque M2Kmax [Nm]0
Max. radial force Frmax [N] for 30,000 h11400
Max. radial force Frmax [N] for 20,000 h12500
Max. axial force Famax [N] for 30,000 h13200
Max. axial force Famax [N] for 20,000 h15000
Operating noise LPA [dB(A)]70
Efficiency at full load ŋ [%]94
Min. operating temperature BTempmin [°C]-25
Max. operating temperature BTempmax [°C]90
Mounting orientationAny
Degree of protectionIP 65
Weight m [kg]21.5
Moment of inertia J1 [kgcm²]5.028

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.