B&R 8I0IF108.400-2
ACOPOSinverter P76 interface module, 2x POWERLINK interface POWERLINK communication cards available in following packages: 8I76S200018.0P-000 8I76S200037.0P-000 8I76S200055.0P-000 8I76S200075.0P-000 8I76S200110.0P-000 8I76S200150.0P-000 8I76S200220.0P-000 8I76T400037.0P-000 8I76T400055.0P-000 8I76T400075.0P-000 8I76T400110.0P-000 8I76T400150.0P-000 8I76T400220.0P-000 8I76T400300.0P-000 8I76T400400.0P-000 8I76T400550.0P-000 8I76T400750.0P-000 8I76T401100.0P-000 8I76T401500.0P-000
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
Short description
| Communication module | POWERLINK V2 controlled node |
General information
| Diagnostics / Module status | Yes, using LED status indicator and software |
| Diagnostics / Bus function | Yes, using LED status indicator and software |
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | In preparation |
| B&R ID code | 0xF25A |
| Status indicators | Module status, bus function |
Interfaces
| Transfer / Physical layer | 100BASE-TX |
| Transfer / Half-duplex | Yes |
| Transfer / Full-duplex | No |
| Transfer / Autonegotiation | Yes |
| Transfer / Auto-MDI/MDIX | Yes |
| Fieldbus | POWERLINK V2 controlled node |
| Type | Type 2 |
| Variant | 2x shielded RJ45 (hub) |
| Line length | Max. 100 m between 2 stations (segment length) |
| Transfer rate | 100 Mbit/s |
| Hub propagation delay | 0.96 to 1 μs |
Operating conditions
| Mounting orientation / Horizontal | Yes |
| Mounting orientation / Vertical | Yes |
| Installation elevation above sea level / 0 to 2000 m | No limitation |
| Installation elevation above sea level / >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature / Operation / Horizontal mounting orientation | -10 to 50°C |
| Temperature / Operation / Vertical mounting orientation | -20 to 60°C |
| Temperature / Derating | - |
| Temperature / Storage | -25 to 70°C |
| Relative humidity / Operation | 5 to 95%, non-condensing |
| Relative humidity / Storage | 5 to 95%, non-condensing |
| Relative humidity / Transport | 5 to 95%, non-condensing |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.