B&R 8I0IF109.400-2
2x X2X Link interface, interface module for ACOPOSinverter P64new X2X Link communication cards available in following packages: 8I64S200018.0X-000 8I64S200037.0X-000 8I64S200055.0X-000 8I64S200075.0X-000 8I64S200110.0X-000 8I64S200150.0X-000 8I64S200220.0X-000 8I64T200018.0X-000 8I64T200037.0X-000 8I64T200055.0X-000 8I64T200075.0X-000 8I64T200110.0X-000 8I64T200150.0X-000 8I64T200220.0X-000 8I64T200300.0X-000 8I64T200400.0X-000 8I64T200550.0X-000 8I64T200750.0X-000 8I64T201100.0X-000 8I64T201500.0X-000 8I64T400037.0X-000 8I64T400055.0X-000 8I64T400075.0X-000 8I64T400110.0X-000 8I64T400150.0X-000 8I64T400220.0X-000 8I64T400300.0X-000 8I64T400400.0X-000 8I64T400550.0X-000 8I64T400750.0X-000 8I64T401100.0X-000 8I64T401500.0X-000
View in our catalog →Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
Short description
| Bus receiver | X2X Link bus receiver |
General information
| Diagnostics / Module run/error | Yes, using LED status indicator and software |
| Diagnostics / Overload | Yes, using LED status indicator and software |
| Power consumption / External I/O | 500 mW |
| Electrical isolation / X2X Link - Frequency inverter | Yes |
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | In preparation |
| B&R ID code | 0xB0E4 |
| Status indicators | Operating state, module status |
| Additional power dissipation caused by actuators (resistive) [W] | - |
Operating conditions
| Mounting orientation / Vertical | Yes |
| Installation elevation above sea level / 0 to 2000 m | No limitation |
| Installation elevation above sea level / >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature / Operation | -10 to 60°C |
| Temperature / Storage | -40 to 85°C |
| Temperature / Transport | -40 to 85°C |
| Relative humidity / Operation | 5 to 95%, non-condensing |
| Relative humidity / Storage | 5 to 95%, non-condensing |
| Relative humidity / Transport | 5 to 95%, non-condensing |
Mechanical properties
| Note | Terminal blocks must be ordered separately. 2x 8TB2104.2010-00 (corresponds to 0TB704.9) or 2x 8TB2104.2210-00 (corresponds to 0TB704.91) or 1x 8TB2108.2010-00 or 1x 8TB2108.2210-00 |