IAC

B&R 8I64T200055.00X-1

ACOPOSinverter X64, 3x 200-240 V, 0.55 kW, integrated brake chopper, shield plate included in delivery, X2X Link interface

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Motor power
Specified on nameplate0.55 kW 0.75 PS
Mains connection
Max. mains current with optional mains choke / At 200 VAC2.5 A
Max. mains current with optional mains choke / At 240 VAC2.2 A
Max. mains current / At 200 VAC4.9 A
Max. mains current / At 240 VAC4.2 A
Mains input voltage3x 200 VAC -15% to 240 VAC +10%
Frequency50 to 60 Hz ±5%
Apparent power (at 240 VAC)1.7 kVA
Max. assumed short-circuit current (Isc) (short-circuit current at connection point)5 kA
Power dissipation at max. output current43 W
Integrated EMC filterNo
Line-conducted and radiated emissions
With add-on filter / Motor cable length per IEC/EN 61800-3 Cat. C1 environment 1 (public power network)-
With add-on filter / Motor cable length per IEC/EN 61800-3 Cat. C2 environment 1 (public power network)≤5 m
With add-on filter / Motor cable length per IEC/EN 61800-3 Cat. C3 environment 2 (industrial power system)≤5 m
With add-on filter8I0FT007.200-1
Motor connection
Derating of continuous output current depending on ambient temperature / Clock frequency 4 kHzNo derating (up to 50°C)
Derating of continuous output current depending on ambient temperature / Other clock frequenciesThe derating curves are included in the installation instructions, which can be downloaded from www.br-automation.com.
Derating of continuous output current depending on installation elevation / Starting at 1000 m above sea level1%, per 100 m
Max. continuous output current (In) / At 240 VAC3.7 A
Nominal clock frequency / Min.2 kHz
Nominal clock frequency / Max.16 kHz
Braking torque / With braking resistor100% of the nominal motor torque continuously, up to 150% for 60 s
Braking torque / Without braking resistor (typical value)100% of the nominal motor torque
Max. motor cable length / Shielded cable50 m
Max. motor cable length / Non-shielded cable100 m
Max. transient current for 60 s5.6 A
Output frequency range0.5 to 500 Hz
Nominal clock frequency4 kHz
Short-term overload torque (typical value)170 to 200% of the nominal motor torque
Motor control profilesStandard profile (voltage/frequency ratio - V/f characteristic curve) Power profile (flux vector control without encoder) Pump/Fan profile (quadratic characteristic curve Kn²) Energy-saving profile (especially for ventilation)
Main protective functions of inverterThermal protection against overheating Protection against short circuits between motor phases Protection against mains phase failure, for 3-phase power supply Protection against motor phase failures Overcurrent protection between motor output phases and ground Overvoltage and undervoltage protection for mains supply
Motor protectionThermal protection integrated in the inverter through continually calculating the l²t value
Brake chopper
Integrated dynamic brake transistorsYes
Operating ratio for dynamic brake transistorsThe dynamic brake transistor is designed to tolerate the following values: -Nominal motor power continuously -150% of the nominal motor power for 60 s
Min. resistance value (external)40 Ω
Available internal power supplies
Output voltage / Max. output current100 mA
Output voltage24 VDC (min. 19 V, max. 30 V)
Interfaces
TypeX2X and CANopen
Min. cycle time400 µs
Digital inputs
Electrical isolation / Input - ACOPOSinverterYes
Electrical isolation / Input - InputNo
Quantity4 (2 can be used as counters)
Nominal voltage24 VDC
Input circuitSource or sink
Sampling time<4 ms
Input impedance12.1 kΩ
Counter input
Quantity2 (digital inputs - can be used as counters)
Counter frequency10 kHz
Counter size32-bit
Digital outputs
Quantity1
Nominal voltage24 VDC
Output circuitSource
Nominal output current0.5 A
Relay outputs
Switching capacity / Max. / With resistive load (cos φ = 1 and L/R = 0 ms)2 A for 250 VAC or 30 VDC
Switching capacity / Max. / With inductive load (cos φ = 0.4 and L/R = 7 ms)1.5 A for 250 VAC or 30 VDC
Switching capacity / Min.10 mA for 5 VDC
Electrical isolation / Output - ACOPOSinverterYes
Electrical isolation / Output - OutputNo
Quantity1
Execution1 NO contact
Nominal voltage30 VDC / 250 VAC
Response time (max.)<8 ms
Operating conditions
Installation elevation above sea level0 to 1000 m
Degree of protection per EN 60529IP31 and IP41 on the upper part and IP21 on the terminals
Ambient temperature-10 to 50°C
Max. ambient temperatureUp to +60°C
Relative humidity per IEC 60068-2-35 to 95%, non-condensing No dripping water
Maximum installation elevationUp to 2000 m
Max. pollution degree per IEC/EN 61800-5-12 (non-conductive pollution)
Ambient conditions per IEC 60721-3-3Class 3C3 and 3S2
Operating positionVertical mounting orientation ±10%
Ambient conditions
Temperature / Storage-25 to 70°C
Mechanical properties
Dimensions / Width72 mm
Dimensions / Height145 mm
Dimensions / Depth132 mm
Weight0.9 kg

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.