ACOPOSinverter P74new, 3x 380-500 V, 1.1 kW, integrated EMC filter and brake chopper, shield plate included in delivery.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

General information
Certifications / CEYes
Certifications / ULUL E225616 Power conversion equipment
Certifications / CSACSA E272421 Industrial control equipment
Motor power
Specified on nameplate1.1 kW (1¹/² HP)
Mains connection
Mains current / At 380 VAC5 A
Mains current / At 500 VAC3.8 A
Mains input voltage3x 380 VAC -15% to 500 VAC +10%
Frequency50 to 60 Hz ±5%
Apparent power (at 500 VAC)3.3 kVA
Max. assumed short-circuit current (Isc) (short-circuit current at connection point)5 kA
Inrush currentMax. 10 A
Power dissipation at nominal load and nominal clock frequency50 W
Integrated EMC filterYes
Line-conducted and radiated emissions
With integrated filter / Motor cable length per IEC/EN 61800-3 Cat. C1 environment 1 (public power network)-
With integrated filter / Motor cable length per IEC/EN 61800-3 Cat. C2 environment 1 (public power network)C2 level of 4 to 12 kHz with 5 m cable
With integrated filter / Motor cable length per IEC/EN 61800-3 Cat. C3 environment 2 (industrial power system)5 m
With add-on filter / Motor cable length per IEC/EN 61800-3 Cat. C1 environment 1 (public power network)C1 level of 2 to 16 kHz with 20 m cable
With add-on filter / Motor cable length per IEC/EN 61800-3 Cat. C2 environment 1 (public power network)C2 level of 2 to 16 kHz with 50 m cable
With add-on filter / Motor cable length per IEC/EN 61800-3 Cat. C3 environment 2 (industrial power system)50 m
With add-on filter8I0FT015.200-1
Motor connection
Derating of continuous output current depending on ambient temperature / At nominal clock frequency (4 kHz)No derating (up to 50°C)
Derating of continuous output current depending on ambient temperature / Other clock frequenciesThe derating curves are included in the installation instructions, which can be downloaded from www.br-automation.com.
Derating of continuous output current depending on installation elevation / Starting at 1000 m above sea level1%, per 100 m
Clock frequency / Min.2 kHz
Clock frequency / Max.16 kHz
Braking torque / With braking resistorUp to 170% of the nominal motor torque
Max. motor cable length / Shielded cable50 m
Max. motor cable length / Non-shielded cable100 m
Motor control profiles / Induction motorSensorless vector control: 1. With V/f characteristic curve for constant torque → Default profile 2. With V/f characteristic curve for quadratically increasing torque → Energy-saving profile, e.g. for fans and pumps Sensorless slip control: 1. With V/f characteristic curve for constant torque → Default profile 2. With V/f characteristic curve for constant torque (6 f ranges) → Profile for individual special applications 3. With V/f characteristic curve for quadratically increasing torque → Energy-saving profile, e.g. for fans and pumps
Motor control profiles / Synchronous motorSensorless vector control: 1. With V/f characteristic curve for constant torque → Default profile
Nominal output current3 A
Max. transient current for 60 s4.5 A
Max. transient current for 2 s5 A
Output frequency range0.1 to 599 Hz
Nominal clock frequency4 kHz
Main protective functions of inverterThermal protection against power stage overheating Protection against short circuits between motor phases, overcurrent between output phases and ground, overvoltages on the DC bus, exceeding the speed limit. Safety function for: Overvoltage and undervoltage of the mains supply, mains phase failure with 3-phase power supply
Brake chopper
Integrated dynamic brake transistorsYes
Min. resistance value (external)54 Ω
24 VDC power supply
Input voltage24 VDC (-15%/+20%)
CurrentMax. 1.1 A
Available internal power supplies
Output voltage 24 VDC / Max. output current at 24 VDC100 mA
Output voltage 10 VDC / Max. output current at 10 VDC10 mA
Output voltage 24 VDC24 VDC (-15%/+20%)
Output voltage 10 VDC10 VDC (-0%/+10%)
Interfaces
POWERLINK / TypeType 2
Digital inputs
Input circuit / Current consumption7 mA
Electrical isolation / Input - ACOPOSinverterYes
Electrical isolation / Input - InputNo
Digital input 5 / Max. input frequency20 kHz
Quantity6
Nominal voltage24 VDC (max. 30 V)
Input circuitSource or sink
Sampling time8 ms ±0.7 ms
Input impedance3.5 kΩ
Safe input - STO (Safe Torque Off)
Input impedance / Current consumption16 mA
Switching threshold / Low<2 V
Switching threshold / High>17 V
Electrical isolation / Input - ACOPOSinverterYes
Electrical isolation / Input - InputNo
Quantity1
Nominal voltage24 VDC
Input impedance1.5 kΩ
Input circuitSink
Sampling time4 ms
Analog inputs
Electrical isolation / Input - InputNo
Electrical isolation / Input - ACOPOSinverterYes
Input / Voltage0 to 10 V, ±10 V
Input / Current0 to 20 mA (or 4 to 20 mA)
Input impedance / Voltage30 kΩ
Input impedance / Current250 Ω
Quantity3
Resolution10-bit
Sampling time2 ms
Digital outputs
Quantity1
Nominal voltage24 VDC
Max. voltage30 VDC
Output circuitSource or sink
Sampling time2 ms
Max. current100 mA
Relay outputs
Variant / Relay 11 changeover contact
Variant / Relay 21 normally open contact
Electrical isolation / Output - ACOPOSinverterYes
Electrical isolation / Output - OutputNo
Quantity2
Nominal voltage30 VDC / 250 VAC
Switching capacityR1, with resistive load (cos phi = 1): 3 A at 250 VAC, R1, with resistive load (cos phi = 1): 4 A at 30 VDC, R1, R2, with inductive load (cos = 0.4 and L/R = 7 ms): 2 A at 250 VAC, R1, R2, with inductive load (cos = 0.4 and L/R = 7 ms): 2 A at 30 VDC, R2 with resistive load (cos phi = 1): 5 A at 250 VAC, R2 with resistive load (cos phi = 1): 5 A at 30 VDC
Response time (max.)2 ms
Analog outputs
Electrical isolation / Output - ACOPOSinverterYes
Electrical isolation / Output - OutputNo
Max. load impedance / Voltage470 Ω
Max. load impedance / Current800 Ω
Quantity1
Output0 to 10 V or 0 to 20 mA
Update time2 ms
Resolution10-bit
Operating conditions
Degree of protection per EN 60529IP20
Relative humidity per IEC 60068-2-35 to 95%. non-condensing No dripping water
Maximum installation elevationUp to 2000 m
Max. pollution degree per IEC/EN 61800-5-12 (non-conductive pollution)
Ambient conditions per IEC 60721-3-3Class 3C3 and 3S3
Operating positionVertical mounting orientation ±10%
Ambient conditions
Temperature / Operation-10 to 50°C without derating 50 to 60°C with derating
Temperature / Storage-25 to 70°C
Max. vibration resistance1 gn 13 to 200 Hz EN/IEC 60068-2-6 1.5 mm peak to peak 3 to 13 Hz EN/IEC 60068-2-6
Mechanical properties
Dimensions / Width45 mm
Dimensions / Height317 mm
Dimensions / Depth245 mm
Weight1.705 kg

Documentation & CAD