IAC

B&R 8I76S200075.00-000

Base device for ACOPOSinverter P76 and P74new, 1 x 200 to 240 V, 0.75 kW, integrated EMC filter and brake chopper, shield plate included in delivery Order number - ACOPOSinverter P76: 8I76S200075.0P-000: Inverter with POWERLINK communication card Order number - ACOPOSinverter P74new: 8I74S200075.0P-000: Inverter with POWERLINK communication card

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

General information
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / ULcULus E225616 Power conversion equipment
Motor power
Specified on nameplate0.75 kW (1 HP)
Mains connection
Mains current / At 200 VAC8.9 A
Mains current / At 240 VAC7.5 A
Mains input voltage1x 200 VAC -15% to 240 VAC +10%
Frequency50 to 60 Hz ±5%
Apparent power (at 240 VAC)1.8 kVA
Max. assumed short-circuit current (Isc) (short-circuit current at connection point)1 kA
Inrush currentMax. 9.6 A
Power dissipation at nominal load and nominal clock frequency51 W
Integrated EMC filterYes
Line-conducted and radiated emissions
With integrated filter / Motor cable length per IEC/EN 61800-3 Cat. C1 environment 1 (public power network)-
With integrated filter / Motor cable length per IEC/EN 61800-3 Cat. C2 environment 1 (public power network)C2 level of 2 to 4 kHz with 10 m cable C2 level of 4 to 12 kHz with 5 m cable
With integrated filter / Motor cable length per IEC/EN 61800-3 Cat. C3 environment 2 (industrial power system)10 m
With add-on filter / Motor cable length per IEC/EN 61800-3 Cat. C1 environment 1 (public power network)C1 level of 2 to 16 kHz with 20 m cable
With add-on filter / Motor cable length per IEC/EN 61800-3 Cat. C2 environment 1 (public power network)C2 level of 2 to 6 kHz with 50 m cable C2 level at 2 kHz with 100 m cable
With add-on filter / Motor cable length per IEC/EN 61800-3 Cat. C3 environment 2 (industrial power system)50 m
With add-on filter8I0FS009.200-2
Motor connection
Derating of continuous output current depending on ambient temperature / At nominal clock frequency (4 kHz)No derating (up to 50°C)
Derating of continuous output current depending on ambient temperature / Other clock frequenciesThe derating curves are included in the installation instructions, which can be downloaded from www.br-automation.com.
Derating of continuous output current depending on installation elevation / Starting at 1000 m above sea level1%, per 100 m
Clock frequency / Min.2 kHz
Clock frequency / Max.16 kHz
Braking torque / With braking resistorUp to 170% of the nominal motor torque
Max. motor cable length / Shielded cable50 m
Max. motor cable length / Non-shielded cable100 m
Motor control profiles / Induction motorSensorless vector control: 1. Voltage controlled with constant torque → standard mode 2. Voltage controlled with variable torque → energy saving mode e.g. for fans and pumps Sensorless slip control: 1. With V/f characteristic curve for constant torque → standard mode 2. With V/f characteristic curve for constant torque (up to 6 f-ranges) → Custom mode for special applications 3. With V/f characteristic curve for quadratically increasing torque → Energy-saving profile, e.g. for fans and pumps
Motor control profiles / Synchronous motorSensorless vector control: 1. Voltage controlled with constant torque → standard mode
Nominal output current4.8 A
Max. transient current for 60 s7.2 A
Output frequency range0.1 to 599 Hz
Nominal clock frequency4 kHz
Main protective functions of inverterThermal protection against power stage overheating Protection against short circuits between motor phases, overcurrent between output phases and ground, overvoltages on the DC bus, exceeding the speed limit. Safety function for: Overvoltage and undervoltage of the mains supply, mains phase failure with 3-phase power supply
Brake chopper
Integrated dynamic brake transistorsYes
Min. resistance value (external)40 Ω
24 VDC power supply
Input voltage24 VDC (-15%/+20%)
CurrentMax. 1.1 A
Available internal power supplies
Output voltage 24 VDC / Max. output current at 24 VDC100 mA
Output voltage 10 VDC / Max. output current at 10 VDC10 mA
Output voltage 24 VDC24 VDC (-15%/+20%)
Output voltage 10 VDC10 VDC (-0%/+10%)
Interfaces
POWERLINK / TypeType 3
Digital inputs
Electrical isolation / Input - ACOPOSinverterYes
Electrical isolation / Input - InputNo
Digital input 5 / Max. input frequency20 kHz
Quantity6
Nominal voltage24 VDC (max. 30 VDC)
Input circuitSource or sink
Sampling time8 ms ±0.7 ms
Safe input - STO (Safe Torque Off)
Input impedance / Current consumption16 mA
Electrical isolation / Input - ACOPOSinverterYes
Electrical isolation / Input - InputNo
Quantity1
Nominal voltage24 VDC (max. 30 VDC)
Input impedance1.5 kΩ
Analog inputs
Electrical isolation / Input - InputNo
Electrical isolation / Input - ACOPOSinverterYes
Input / VoltageAI1: 0 to 10 VDC AI2: 0 ±10 VDC, max. 30 VDC
Input / Current0 to 20 mA (or 4 to 20 mA)
Input impedance / Voltage30 kΩ
Input impedance / Current250 Ω
Quantity3
Nonlinearity±0.2%, max. ±0.5%
Basic accuracyAt 25°C: ±0.5% At -10 to 60°C: ±0.7%
Resolution10-bit
Sampling time2 ms
Digital outputs
Quantity1
Nominal voltage24 VDC -15% / +20%
Max. voltage30 VDC
Output circuitSource or sink
Sampling time2 ms
Max. current100 mA
Relay outputs
Execution / Relay 11 changeover contact
Execution / Relay 21 normally open contact
Electrical isolation / Output - ACOPOSinverterYes
Electrical isolation / Output - OutputNo
Quantity2
Nominal voltage30 VDC / 250 VAC
Switching current rangeMin. switching current: 5 mA at 24 VDC Max. switching current: R1 at cos φ = 1: 3 A at 250 VAC / 4 A at 30 VDC R2 at cos φ = 1: 5 A R1 and R2 at cos φ = 0.4: 2 A
Response time (max.)2 ms
Analog outputs
Electrical isolation / Output - ACOPOSinverterYes
Electrical isolation / Output - OutputNo
Max. load impedance / Voltage470 Ω
Max. load impedance / Current800 Ω
Quantity1
Output0 to 10 V or 0 to 20 mA
Nonlinearity±0.3%
Basic accuracyAt 25°C: ±1% At -10 to 60°C: ±2%
Update time2 ms
Resolution10-bit
Electrical properties
Energy efficiency (IE classification) / Power dissipation relative to continuous apparent powerIE2 (10; 25): 1.3% (1x 200 VAC); 1.2% (1x 240 VAC) IE2 (50; 25): 1.3% (1x 200 VAC); 1.1% (1x 240 VAC) IE2 (10; 50): 1.6% (1x 200 VAC); 1.4% (1x 240 VAC) IE2 (50; 50): 1.6% (1x 200 VAC); 1.3% (1x 240 VAC) IE2 (90; 50): 1.7% (1x 200 VAC); 1.4% (1x 240 VAC) IE2 (10; 100): 2.4% (1x 200 VAC); 2.1% (1x 240 VAC) IE2 (50; 100): 2.3% (1x 200 VAC); 1.9% (1x 240 VAC) IE2 (90; 100): 2.7% (1x 200 VAC); 2.2% (1x 240 VAC)
Energy efficiency (IE classification) / Nominal losses in standby mode6 W
Operating conditions
Degree of protection per EN 61800-5-1IP20
Relative humidity per IEC 60068-2-35 to 95%, non-condensing No dripping water
Maximum installation elevation≤1000 m without derating 1000 to 2000 m with Derating
Max. pollution degree per IEC/EN 61800-5-12 (non-conductive pollution)
Ambient conditions per IEC 60721-3-3Class 3C3 and 3S2
Operating positionVertical mounting orientation ±10°
Ambient conditions
Temperature / Operation-10 to 50°C without derating 50 to 60°C with derating
Temperature / Storage-25 to 70°C
Max. vibration resistance1 gn 13 to 200 Hz EN/IEC 60068-2-6 1.5 mm peak to peak 3 to 13 Hz EN/IEC 60068-2-6
Mechanical properties
Dimensions / Width45 mm
Dimensions / Height325 mm
Dimensions / Depth232 mm
Weight2.4 kg

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.